SICK

TIM510-9950000S01

SKU: 1062210 Disponible sur commande
Prix hors TVA

Demander un devis

    LiDAR sensors | TiM | TIM510-9950000S01 | Integrated application: Output of measurement data | Measurement principle: HDDM+ | Working range: 0.05 m ... 4 m | Enclosure rating: IP65 | Digital outputs: 1 (PNP, "SYNC"/"device ready") | Connection type: 1 x cable with 12-pin M12 male connector (0,3 m), 1 x Micro USB female connector, type B

    Application
    Indoor
    Measurement principle
    HDDM+
    Light source
    Infrared (850 nm)
    Laser class
    1 (IEC 60825-1:2014, EN 60825-1:2014+A11:2021)
    Scanning frequency
    15 Hz
    Horizontal
    Working range
    0.05 m ... 4 m
    At 10% remission factor
    2 m
    Connection type
    1 x cable with 12-pin M12 male connector (0,3 m)1 x Micro USB female connector, type B
    Supply voltage
    9 V DC ... 28 V DC
    Power consumption
    Typ. 4 W
    Output current
    ≤ 100 mA
    Housing color
    Light blue (RAL 5012)
    Enclosure rating
    IP65 (IEC 60529:1989+AMD1:1999+AMD2:2013)
    Protection class
    III (IEC 61140:2016-1)
    Poids
    150 g, without connecting cables
    Dimensions (L x W x H)
    60 mm x 60 mm x 79 mm
    MTBF
    > 100 years
    MTTFD
    100 years
    Response time
    1 scan, typ. 67 ms2 scans, ≤ 134 ms1)
    Detectable object shape
    Almost any
    Systematic error
    ± 40 mm2)
    Statistical error
    < 30 mm2)
    Integrated application
    Output of measurement data
    Serial
    ✔ , RS-232
    Data transmission rate
    460.8 kBaud
    USB
    Remark
    Micro USB
    Function
    Service interface, parameterization
    Inputs
    0
    Outputs
    1 (PNP, "SYNC"/"device ready")
    Optical indicators
    2 LEDs (ON, switching status)
    Remission factor
    4 % ... 1,000 % (reflectors)
    Emitted radiation
    Residential area (EN 61000-6-3:2007+AMD:A1:2011)
    Electromagnetic immunity
    Industrial environment (EN 61000-6-2:2005)
    Sine resonance scan
    10 Hz ... 1,000 Hz1)
    Sine test
    10 Hz ... 500 Hz, 5 g, 10 frequency cycles1)
    Noise test
    10 Hz ... 250 Hz, 4.24 g RMS, 5 h2)
    Shock resistance
    50 g, 11 ms, ± 3 single shocks/axis3)25 g, 6 ms, ± 1,000 continuous shocks/axis3)50 g, 3 ms, ± 5,000 continuous shocks/axis3)
    Ambient operating temperature
    –10 °C ... +50 °C4)
    Storage temperature
    –30 °C ... +70 °C4)
    Temperature change
    –25 °C ... +50 °C, 10 cycles5)
    Damp heat
    +25 °C ... +55 °C, 95 % RH, 6 cycles6)
    Operation
    < 80 %, Non-condensing (EN 60068-2-30:2005)
    Storage
    ≤ 95 %, Non-condensing (EN 60068-2-30:2005)
    Ambient light immunity
    80,000 lx
    Note on use
    The sensor does not constitute a safety component as defined by relevant legislation on machine safety.
    EU declaration of conformity
    UK declaration of conformity
    ACMA declaration of conformity
    China RoHS
    KC Mark certificate
    cTUVus certificate
    Information according to Art. 3 of Data Act (Regulation EU 2023/2854)
    ECLASS 5.0
    27270990
    ECLASS 5.1.4
    27270990
    ECLASS 6.0
    27270913
    ECLASS 6.2
    27270913
    ECLASS 7.0
    27270913
    ECLASS 8.0
    27270913
    ECLASS 8.1
    27270913
    ECLASS 9.0
    27270913
    ECLASS 10.0
    27270913
    ECLASS 11.0
    27270913
    ECLASS 12.0
    27270913
    ETIM 5.0
    EC002550
    ETIM 6.0
    EC002550
    ETIM 7.0
    EC002550
    ETIM 8.0
    EC002550
    UNSPSC 16.0901
    41111615
    Télécharger la fiche technique

    Manuels, modèles CAO, certificats et autres documents — sur le site du fabricant :

    Ouvrir la page produit sur le site du fabricant