SICK

WTM12L-34161820A00

SKU: 1126054 Доступно к заказу
Цена без НДС

Запросить цену

    Photoelectric sensors | W12 | WTM12L-34161820A00 | Sensing range min. / max.: 15 mm / 420 mm, 0 mm / 150 mm, 15 mm / 650 mm | Functional principle: Photoelectric proximity sensor | Functional principle detail: Background suppression, Foreground suppression, MultiMode, distance value | Switching output: Push-pull: PNP/NPN | Switching mode: Light/dark switching | Connection type: Cable with M12 male connector, 4-pin, 315 mm | Light source: Laser | Type of light: Visible red light | Laser class: 1 | Housing material: Zinc diecast | Adjustment: Teach-in button, Potentiometer, Teach-Turn adjustment, IO-Link | Communication interface: IO-Link V1.1 | Smart Sensor: Enhanced Sensing, efficient communication, diagnosis, Smart Task | Smart Task name: Base logics | Special features: MultiMode | Housing: Rectangular

    Functional principle
    Photoelectric proximity sensor
    Functional principle detail
    Background suppression, Foreground suppression, MultiMode, distance value
    MultiMode
    1 Background suppression2 Foreground suppression3 Two Value Teach-in4 Two independent switching points5 Window6 ApplicationSelectM manual / measurement
    Sensing range min.
    15 mm (mode 1, 3, 4, 5)
    Sensing range max.
    420 mm (mode 1, 3, 4, 5)
    Adjustable switching threshold for background suppression
    30 mm ... 420 mm (mode 1, 3, 4, 5)
    Adjustable switching threshold for foreground suppression
    35 mm ... 150 mm (mode 2)
    Reference object
    Object with 90% remission factor (complies with standard white according to DIN 5033)
    Minimum distance between set sensing range and background (black 6% / white 90%)
    4 mm, at a distance of 140 mm (mode 1, 3, 4, 5)
    Minimum object height at set sensing range in front of black background (6% remission factor)
    2 mm, at a distance of 90 mm (mode 2)
    Recommended sensing range for the best performance
    40 mm ... 160 mm (mode 1, 3, 4, 5)
    Resolution
    0.1 mm
    Accuracy
    Typ. 2.0 mm at 30 ... 120 mm distance1)
    Distance value output
    Via IO-Link
    Update rate of the distance value
    20 ms
    Light source
    Laser
    Type of light
    Visible red light
    Shape of light spot
    Ellipse shape
    Light spot size (distance)
    2.4 mm x 1 mm (160 mm)
    Maximum dispersion of the emitted beam around the standardized transmission axis (squint angle)
    < +/- 1.0° (at TU= +23 °C)
    Normative reference
    EN 60825-1:2014, IEC 60825-1:2014
    Laser class
    14)
    Wave length
    655 nm
    Pulse duration
    4 µs
    Maximum pulse power
    < 4.03 mW
    Average service life
    50,000 h at TU= +25 °C
    Teach-Turn adjustment
    BluePilotFor adjusting the sensing range with mode selection
    LED blue
    BluePilot: Display of mode, display of output states QL1(LED 3 permanently on) and QL2(LED 5 permanently on)
    LED green
    Operating indicatorStatic on: power onFlashing: IO-Link mode
    LED yellow
    Status of received light beamStatic on: object presentStatic off: object not present
    Special features
    MultiMode
    Special applications
    Detecting small objects, Detection of objects moving at high speeds, Detecting flat objects, Detecting uneven, shiny objects, Detection of poorly remitting and tilted objects, Detecting perforated objects
    MTTFD
    280 years
    DCavg
    0 %
    TM(mission time)
    10 years
    IO-Link
    ✔ , IO-Link V1.1
    Data transmission rate
    COM2 (38,4 kBaud)
    Cycle time
    2.3 ms
    Process data length
    16 Bit
    Process data structure
    Bit 0 = switching signal QL1
    VendorID
    26
    DeviceID HEX
    0x8002D2
    DeviceID DEC
    8389330
    Compatible master port type
    A
    SIO mode support
    Yes
    Supply voltage UB
    10 V DC ... 30 V DC1)
    Ripple
    ≤ 5 V
    Usage category
    DC-12 (According to EN 60947-5-2)DC-13 (According to EN 60947-5-2)
    Current consumption
    ≤ 14 mA, without load. At UB= 24 V
    Protection class
    III
    Number
    2 (Complementary)
    Type
    Push-pull: PNP/NPN
    Switching mode
    Light/dark switching
    Signal voltage PNP HIGH/LOW
    Approx. UB-2.5 V / 0 V
    Signal voltage NPN HIGH/LOW
    Approx. UB/ < 2.5 V
    Output current Imax.
    ≤ 100 mA
    Circuit protection outputs
    Reverse polarity protected
    Repeatability (response time)
    85 µs (mode 1, 2, 3)2)
    BN 1
    + (L+)
    WH 2
    ǬL1/MFDigital output, dark switching, object present → output ǬL1 LOW (Mode 1, 3, 5, 6)7)The pin 2 function of the sensor can be configured
    BU 3
    - (M)
    BK 4
    QL1/CDigital output, light switching, object present → output QL1 HIGH (Mode 1, 3, 4, 5, 6)7)The pin 4 function of the sensor can be configured
    Dimensions (W x H x D)
    15.6 mm x 49.5 mm x 43.1 mm
    Connection
    Cable with M12 male connector, 4-pin, 315 mm
    Deep-freeze property
    Do not bend below 0 °C
    Conductor size
    0.14 mm²
    Cable diameter
    Ø 3.4 mm
    Length of cable (L)
    275 mm
    Bending radius
    For flexible use > 12 x cable diameter
    Bending cycles
    1,000,000
    Housing
    Metal, zinc diecast
    Front screen
    Plastic, PMMA
    Cable
    Plastic, PVC
    Male connector
    Plastic, VISTAL®
    Вес
    Approx. 94 g
    Maximum tightening torque of the fixing screws
    1.4 Nm
    Enclosure rating
    IP66 (EN 60529)IP67 (EN 60529)IP69 (EN 60529)
    Ambient operating temperature
    –20 °C ... +55 °C
    Ambient temperature, storage
    –40 °C ... +70 °C
    Warm-up time
    < 15 min, Where Tuis under –10 °C
    Typ. Ambient light immunity
    Artificial light: ≤ 50,000 lxSunlight: ≤ 50,000 lx
    Shock resistance
    50 g, 11 ms (25 positive and 25 negative shocks along X, Y, Z axes, 150 total shocks (EN60068-2-27))
    Vibration resistance
    10 Hz ... 2,000 Hz (Amplitude 0.5 mm / 10 g, 20 sweeps per axis, for X, Y, Z axes, 1 octave/min, (EN60068-2-6))
    Air humidity
    35 % ... 95 %, relative humidity (no condensation)
    Electromagnetic compatibility (EMC)
    EN 60947-5-2
    Resistance to cleaning agent
    ECOLAB
    UL File No.
    NRKH.E181493 & NRKH7.E181493
    Smart Task name
    Base logics
    Logic function
    DirectANDOR
    Timer function
    DeactivatedSwitch-on delayOff delayON and OFF delayImpulse (one shot)
    Inverter
    Yes
    Switching frequency
    SIO Logic: 2000 Hz (mode 1, 2, 3)1)SIO Logic: 900 Hz (mode 4, 5)1)SIO Logic: 30 Hz (mode 1 and 6 combined)1)IOL: 1600 Hz (mode 1, 2, 3)2)IOL: 800 Hz (mode 4, 5)2)IOL: 30 Hz (mode 1 and 6 combined)2)
    Response time
    SIO Logic: 250  µs (mode 1, 2, 3)1)SIO logic: 550 µs (mode 4, 5)1)SIO Logic: 15 ms (mode 1 and 6 combined)1)IOL: 300 µs (mode 1, 2, 3)2)IOL: 600 µs (mode 4, 5)2)IOL: 15 ms (mode 1 and 6 combined)2)
    Repeatability
    SIO Logic: 120 µs (mode 1, 2, 3)1)SIO Logic: 200 µs (mode 4, 5)1)SIO Logic: 5 ms (mode 1 and 6 combined)1)IOL: 150 µs (mode 1, 2, 3)2)IOL: 250 µs (mode 4, 5)2)IOL: 5 ms (mode 1 and 6 combined)2)
    Switching signal QL1
    Switching output
    Switching signal ǬL1
    Switching output
    Measuring range
    Very cold, cold, moderate, warm, hot
    Device status
    Yes
    Detailed device status
    Yes
    Operating hour counter
    Yes
    Operating hours counter with reset function
    Yes
    Quality of teach
    Yes
    EU declaration of conformity
    UK declaration of conformity
    ACMA declaration of conformity
    Moroccan declaration of conformity
    China RoHS
    ECOLAB certificate
    cULus certificate
    IO-Link certificate
    Laser safety (IEC 60825-1) declaration of manufacturer
    Information according to Art. 3 of Data Act (Regulation EU 2023/2854)
    ECLASS 5.1.4
    27270903
    ECLASS 6.0
    27270903
    ECLASS 7.0
    27270903
    ECLASS 8.0
    27270903
    ECLASS 9.0
    27270903
    ECLASS 10.0
    27270903
    ECLASS 11.0
    27270903
    ECLASS 12.0
    27270903
    ECLASS 13.0
    27270903
    ECLASS 14.0
    27270903
    ECLASS 15.0
    27270903
    ETIM 6.0
    EC002719
    ETIM 7.0
    EC002719
    ETIM 8.0
    EC002719
    ETIM 9.0
    EC002719
    ETIM 10.0
    EC002719
    UNSPSC 091201.0
    32151804
    UNSPSC 100501.0
    32151804
    UNSPSC 111201.0
    32151804
    UNSPSC 120901.0
    32151804
    UNSPSC 131201.0
    32151804
    UNSPSC 140801.0
    32151804
    UNSPSC 151101.0
    32151804
    UNSPSC 160901.0
    32151804
    UNSPSC 171001.0
    32151804
    UNSPSC 180801.0
    32151804
    UNSPSC 190501.0
    32151804
    UNSPSC 200601.0
    32151804
    UNSPSC 210901.0
    32151804
    UNSPSC 220601.0
    32151804
    UNSPSC 230701.0
    32151804
    UNSPSC 240301.0
    32151804
    UNSPSC 250901.0
    32151804
    UNSPSC 260801.0
    32151804
    Скачать техпаспорт

    Инструкции, CAD-модели, сертификаты и другие материалы — на сайте производителя:

    Открыть страницу товара на сайте производителя