Functional principle
Photoelectric retro-reflective sensor
Functional principle detail
Without reflector minimum distance (autocollimation/coaxial optics)
Sensing range max.
0 m ... 12 m1)
Sensing range
0 m ... 8 m1)
Type of light
Visible red light
Light spot size (distance)
Ø 1 mm (500 mm)
Normative reference
EN 60825-1:2014, IEC 60825-1:2014 / CDRH 21 CFR 1040.10 & 1040.11
Adjustment
IO-Link, Single teach-in button
Special applications
Detecting small objects
Pin 2 configuration
External input, Teach-in input, Sender off input, Detection output, logic output, Device contamination alarm output
MTTFD
562 years (EN ISO 13849-1)1)
IO-Link
✔ , COM2 (38,4 kBaud)
Data transmission rate
COM2 (38,4 kBaud)
Process data length
16 Bit
Process data structure
Bit 0 = switching signal QL1
Supply voltage UB
10 V DC ... 30 V DC1)
Current consumption
30 mA3)
Switching mode
Light/dark switching4)
Output current Imax.
≤ 100 mA
Repeatability (response time)
150 µs7)
Output function
Complementary
Circuit protection
A9)B10)C11)
Response time Q/ on Pin 2
300 µs ... 450 µs6)7)
Switching frequency Q / to pin 2
1,000 Hz12)
Dimensions (W x H x D)
12.2 mm x 41.8 mm x 17.3 mm
Connection
Male connector M8, 4-pin
Front screen
Plastic, PMMA
Ambient operating temperature
–10 °C ... +50 °C
Ambient operating temperature extended
–30 °C ... +55 °C1)2)
Ambient temperature, storage
–30 °C ... +70 °C
Smart Task name
Base logics
Logic function
DirectANDORWINDOWHysteresis
Timer function
DeactivatedSwitch-on delayOff delayON and OFF delayImpulse (one shot)
Switching frequency
SIO Direct: 1000 Hz1)SIO Logic: 1000 Hz2)IOL: 900 Hz3)
Response time
SIO Direct: 300 µs ... 450 µs1)SIO Logic: 500 µs ... 600 µs2)IOL: 500 µs ... 900 µs3)
Repeatability
SIO Direct: 150 µs1)SIO Logic: 150 µs2)IOL: 400 µs3)
Switching signal QL1
Switching output
Switching signal QL2
Switching output
Quality of run
Yes, Contamination display
EU declaration of conformity
✔
UK declaration of conformity
✔
ACMA declaration of conformity
✔
Moroccan declaration of conformity
✔
Laser safety (IEC 60825-1) certificate
✔
Information according to Art. 3 of Data Act (Regulation EU 2023/2854)
✔