SICK

TR4-SDU01CB

SKU: 6070808 Available to order
Price excluding VAT

Request a quote

    Safety switches | TR4 Direct | TR4-SDU01CB | System part: Sensor with actuator | Coding: Uniquely coded | Assured switch on distance Sao: 15 mm | Connection type Detail: Cable with plug M12, 8-pin | Length of cable: 0.2 m | Safe series connection: With Flexi Loop (with diagnostics), with T-connector (without diagnostics) | Status display: yes | Boundary area indication: no

    System part
    Sensor with actuator
    Sensor principle
    RFID
    Number of safe outputs
    2
    Assured switch on distance Sao
    15 mm
    Assured switch off distance Sar
    25 mm
    Active sensor surfaces
    2
    Actuation directions
    5
    Coding
    Uniquely coded
    Safety integrity level
    SIL 3 (IEC 61508)
    Category
    Category 4 (EN ISO 13849)
    Performance level
    PL e (EN ISO 13849)
    PFHD(mean probability of a dangerous failure per hour)
    6.03 * 10-10
    TM(mission time)
    20 years (EN ISO 13849)
    Type
    Type 4 (EN ISO 14119)
    Actuator coding level
    High coding level (EN ISO 14119)
    Classification in compliance with IEC/EN 60947-5-3
    PDF-M
    Safe state in the event of a fault
    At least one safety-related semiconductor output (OSSD) is in the OFF state.
    Safe series connection
    With Flexi Loop (with diagnostics)With T-connector (without diagnostics)
    Connection type
    Cable with plug M12, 8-pin
    Length of cable
    0.2 m
    Long connecting cable
    ≤ 200 m
    Cable diameter
    6.5 mm
    Conductor cross section
    0.25 mm²
    Bend radius (with fixed installation)
    > 7 x cable diameter
    Bend radius (with moving cable)
    > 14 x cable diameter
    Cable material
    PVC
    Conductor material
    Copper
    Coupling nut material
    Nickel-plated brass
    Display elements
    LEDs
    Status display
    Protection class
    III (EN 50178)
    Classification according to cULus
    Class 2
    Supply voltage Vs
    24 V DC (20.4 V DC ... 26.4 V DC)
    Power consumption
    ≤ 50 mA
    Type of output
    Self-monitoring semiconductor outputs (OSSDs)
    Output current
    ≤ 200 mA
    Response time
    45 ms1)
    Release time
    360 ms2)
    Risk time
    ≤ 100 ms3)
    Switch-on time
    2 s4)
    Electrical life
    10 x 106switching cycles
    Design
    Rectangular
    Dimensions (W x H x D)
    25 mm x 88 mm x 20 mm
    Weight
    112 g
    Housing material
    Valox® DR48
    Enclosure rating
    IP67 (IEC 60529)IP69K (ISO 20653)
    Ambient operating temperature
    –25 °C ... +70 °C
    Vibration resistance
    10 Hz ... 55 Hz, 3.5 mm (IEC 60068-2-6)
    Shock resistance
    30 g, 11 ms (EN 60068-2-27)
    EU declaration of conformity
    UK declaration of conformity
    ACMA declaration of conformity
    China RoHS
    cULus certificate
    EC-Type-Examination approval
    ECLASS 5.0
    27272403
    ECLASS 5.1.4
    27272403
    ECLASS 6.0
    27272403
    ECLASS 6.2
    27272403
    ECLASS 7.0
    27272403
    ECLASS 8.0
    27272403
    ECLASS 8.1
    27272403
    ECLASS 9.0
    27272403
    ECLASS 10.0
    27272403
    ECLASS 11.0
    27272403
    ECLASS 12.0
    27274601
    ETIM 5.0
    EC001829
    ETIM 6.0
    EC001829
    ETIM 7.0
    EC001829
    ETIM 8.0
    EC001829
    UNSPSC 16.0901
    39122205