SICK

TiM561-9950101S01

SKU: 1079741 Abandonné
Prix hors TVA

Demander un devis

    LiDAR sensors | TiM | TiM561-9950101S01 | Integrated application: Output of measurement data | Working range: 0.05 m ... 10 m | Enclosure rating: IP67 | Digital outputs: 1 (PNP, "SYNC"/"device ready") | Connection type: 1 x “Ethernet” connection, cable, with RJ45 male connector (1 m)1 x “Power/Synchronization output” connection, 5-wire cable with open end (1 m)1 x Micro USB female connector, type B

    Application
    Outdoor, Indoor
    Light source
    Infrared (850 nm)
    Laser class
    1 (IEC 60825-1:2014, EN 60825-1:2014)
    Scanning frequency
    15 Hz
    Horizontal
    0.33°
    Working range
    0.05 m ... 10 m
    At 10% remission factor
    8 m
    Connection type
    1 x “Ethernet” connection, cable, with RJ45 male connector (1 m)1 x “Power/Synchronization output” connection, 5-wire cable with open end (1 m)1 x Micro USB female connector, type B
    Supply voltage
    9 V DC ... 28 V DC
    Power consumption
    Typ. 4 W
    Output current
    ≤ 100 mA
    Housing color
    Gray (RAL 7032)
    Enclosure rating
    IP67, applies only when the plastic cover of the “Aux interface” is closed (IEC 60529:1989+AMD1:1999+AMD2:2013)
    Protection class
    III (IEC 61140:2016-1)
    Poids
    250 g, without connecting cables
    Dimensions (L x W x H)
    60 mm x 60 mm x 86 mm
    MTBF
    > 100 years
    MTTFD
    100 years
    Response time
    1 scan, typ. 67 ms2 scans, ≤ 134 ms1)
    Detectable object shape
    Almost any
    Systematic error
    ± 60 mm2)
    Integrated application
    Output of measurement data
    Ethernet
    ✔ , TCP/IP
    USB
    Remark
    Micro USB
    Function
    Service interface, parameterization
    Digital inputs
    0
    Digital outputs
    1 (PNP, "SYNC"/"device ready")
    Optical indicators
    2 LEDs (ON, "device ready")
    Object remission
    4 % ... 1,000 % (reflectors)
    Emitted radiation
    Residential area (EN 61000-6-3:2007+AMD:A1:2011)
    Electromagnetic immunity
    Industrial environment (EN 61000-6-2:2005)
    Sine resonance scan
    10 Hz ... 1,000 Hz1)
    Sine test
    10 Hz ... 500 Hz, 5 g, 10 frequency cycles1)
    Noise test
    10 Hz ... 250 Hz, 4.24 g RMS, 5 h2)
    Shock resistance
    50 g, 11 ms, ± 3 single shocks/axis3)25 g, 6 ms, ± 1,000 continuous shocks/axis3)50 g, 3 ms, ± 5,000 continuous shocks/axis3)
    Ambient operating temperature
    –25 °C ... +50 °C4)
    Storage temperature
    –40 °C ... +75 °C4)
    Temperature change
    –25 °C ... +50 °C, 10 cycles5)
    Damp heat
    +25 °C ... +55 °C, 95 % RH, 6 cycles6)
    Operation
    < 80 %, Non-condensing (EN 60068-2-30:2005)
    Storage
    ≤ 95 %, Non-condensing (EN 60068-2-30:2005)
    Ambient light immunity
    80,000 lx
    Note on use
    The sensor does not constitute a safety component as defined by relevant legislation on machine safety.
    ECLASS 5.0
    27270990
    ECLASS 5.1.4
    27270990
    ECLASS 6.0
    27270913
    ECLASS 6.2
    27270913
    ECLASS 7.0
    27270913
    ECLASS 8.0
    27270913
    ECLASS 8.1
    27270913
    ECLASS 9.0
    27270913
    ECLASS 10.0
    27270913
    ECLASS 11.0
    27270913
    ECLASS 12.0
    27270913
    ETIM 5.0
    EC002550
    ETIM 6.0
    EC002550
    ETIM 7.0
    EC002550
    ETIM 8.0
    EC002550
    UNSPSC 16.0901
    41111615
    Télécharger la fiche technique

    Manuels, modèles CAO, certificats et autres documents — sur le site du fabricant :