SICK

TIM361S-2134101

SKU: 1090608 Available to order
Price excluding VAT

Request a quote

    LiDAR sensors | TiM-S | TIM361S-2134101 | Integrated application: Protective field evaluation with flexible fields | Measurement principle: HDDM | Working range: 0.05 m ... 10 m, At > 90% remission factor | Number of field sets: 16 | Enclosure rating: IP67 | Digital outputs: 3 (PNP, to display a detection in the protective field, additional 1 x “Device Ready”) | Connection type: 1 “Ethernet” connection, 4-pin M12 female connector, 1 connection “Power”, 12-pin, M12 male connector, 1 Micro USB female connector, type B

    Application
    Indoor
    System part
    sensor
    Measurement principle
    HDDM
    Light source
    Infrared (850 nm)
    Laser class
    1 (IEC 60825-1:2014, EN 60825-1:2014+A11:2021)
    Scanning frequency
    15 Hz
    Horizontal
    0.33°
    Scan field flatness
    ± 1.5°
    Working range
    0.05 m ... 10 m (At > 90% remission factor)
    Safety-related working range
    0.05 m ... 4 m (At 5% remission factor)
    Blind zone
    0 m ... 0.05 m
    At 10% remission factor
    8 m
    Connection type
    1 x “Ethernet” connection, 4-pin M12 female connector1 x connection “Power”, 12-pin, M12 male connector1 x Micro USB female connector, type B
    Supply voltage
    9 V DC ... 28 V DC
    Power consumption
    Typ. 4 W, 16 W with 4 max. loaded digital outputs
    Output current
    ≤ 100 mA
    Housing color
    Yellow
    Enclosure rating
    IP67, applies only when the plastic cover of the “Aux interface” is closed (IEC 60529:1989+AMD1:1999+AMD2:2013)
    Protection class
    III (IEC 61140:2016-1)
    Weight
    250 g, without connecting cables
    Dimensions (L x W x H)
    60 mm x 60 mm x 86 mm
    MTBF
    > 100 years
    Category
    B (EN ISO 13849-1:2015)
    Performance level
    PL b (EN ISO 13849-1:2015)
    Conformities
    EN ISO 13849-1:2015, EN ISO 13482:2014, EN ISO 13855:2010, ANSI/ITSDF B56.5:2012
    MTTFD(mean time to dangerous failure)
    100 years, at 25 °C ambient temperature (EN ISO 13849-1:2015)
    TM(mission time)
    20 years (EN ISO 13849-1:2015)
    Response time
    1 scan2 scans, ≤ 134 ms1)
    Detectable object shape
    Almost any
    Integrated application
    Protective field evaluation with flexible fields
    Protective field tolerance
    100 mm, 0.66° (DIN CLC/TS 62046:2009, at 5% remission factor)
    Number of field sets
    16 field triples (48 protective fields)
    Simultaneous evaluation cases
    3 simultaneous protective fields (per field set)
    USB
    Remark
    Micro USB
    Function
    Service interface, parameterization
    Inputs
    4 (PNP, for field set switching)
    Outputs
    3 (PNP, to display a detection in the protective field, additional 1 x “Device Ready”)
    Delay time
    67 ms ... 30,000 ms (configurable)
    Dwell time
    67 ms ... 600,052 ms (configurable)
    Optical indicators
    2 LEDs (ON, switching status)
    Remission factor
    ≥ 5 % (reflectors)1)
    Emitted radiation
    Residential area (EN 61000-6-3:2007+AMD:A1:2011)
    Electromagnetic immunity
    Industrial environment (EN 61000-6-2:2005)
    Sine resonance scan
    10 Hz ... 1,000 Hz2)
    Sine test
    10 Hz ... 500 Hz, 5 g, 10 frequency cycles2)
    Noise test
    10 Hz ... 250 Hz, 4.24 g RMS, 5 h3)
    Shock resistance
    50 g, 11 ms, ± 3 single shocks/axis4)25 g, 6 ms, ± 1,000 continuous shocks/axis4)50 g, 3 ms, ± 5,000 continuous shocks/axis4)
    Ambient operating temperature
    –10 °C ... +50 °C5)
    Storage temperature
    –40 °C ... +75 °C5)
    Switch-on temperature
    –10 °C ... +50 °C
    Temperature change
    –25 °C ... +50 °C, 10 cycles6)
    Damp heat
    +25 °C ... +55 °C, 95 % RH, 6 cycles7)
    Operation
    < 80 %, Non-condensing (EN 60068-2-30:2005)
    Storage
    ≤ 90 %, Non-condensing (EN 60068-2-30:2005)
    Ambient light immunity
    60,000 lx3,000 lx, With direct light
    Note on use
    The TiM361S is a safety-related sensor that is suitable for use in the following applications: hazardous area, hazardous point, and access protection as well as mobile hazardous area protection (protection of automated guided vehicles and mobile platforms). The sensor must only ever be used within the limits of the prescribed and specified technical data and operating conditions.
    EU declaration of conformity
    UK declaration of conformity
    ACMA declaration of conformity
    China RoHS
    TÜV approval
    TÜV approval annex
    cTUVus certificate
    EC-Type-Examination approval
    Information according to Art. 3 of Data Act (Regulation EU 2023/2854)
    ECLASS 5.1.4
    27272705
    ECLASS 6.0
    27272705
    ECLASS 7.0
    27272705
    ECLASS 8.0
    27272705
    ECLASS 9.0
    27272705
    ECLASS 10.0
    27272705
    ECLASS 11.0
    27272705
    ECLASS 12.0
    27272705
    ECLASS 13.0
    27272705
    ECLASS 14.0
    27272705
    ECLASS 15.0
    27272705
    ETIM 6.0
    EC002550
    ETIM 7.0
    EC002550
    ETIM 8.0
    EC002550
    ETIM 9.0
    EC002550
    ETIM 10.0
    EC002550
    UNSPSC 091201.0
    39121528
    UNSPSC 100501.0
    39121528
    UNSPSC 111201.0
    39121528
    UNSPSC 120901.0
    39121528
    UNSPSC 131201.0
    39121528
    UNSPSC 140801.0
    39121528
    UNSPSC 151101.0
    39121528
    UNSPSC 160901.0
    39121528
    UNSPSC 171001.0
    39121528
    UNSPSC 180801.0
    39121528
    UNSPSC 190501.0
    39121528
    UNSPSC 200601.0
    39121528
    UNSPSC 210901.0
    39121528
    UNSPSC 220601.0
    39121528
    UNSPSC 230701.0
    39121528
    UNSPSC 240301.0
    39121528
    UNSPSC 250901.0
    39121528
    UNSPSC 260801.0
    39121528
    Download Datasheet

    Manuals, CAD models, certificates and other materials are available on the manufacturer's website:

    Open product page on manufacturer's website