SICK

SLG50S-240FAR21A00

SKU: 1120113 Доступно к заказу
Цена без НДС

Запросить цену

    Automation light grids | SLG-2 | SLG50S-240FAR21A00 | Optical light exit: Flat | Beam separation: 50 mm | Operating range: 3.5 m | Detection height: 2,400 mm | Length of cable: 150 mm

    Included with delivery
    1 × sender1 × receiver1 × Quick Start Guide1 x safety notes
    Functional principle
    Sender/receiver
    Limit values
    440 mm ... 4,900 mm
    Parallel beam (recommended)
    440 mm ... 3,500 mm
    3 x cross beam (recommended)
    440 mm ... 3,500 mm
    Distance from 1st Beam to leading edge of housing (connection side)
    4.6 mm
    Distance from last beam to leading edge of housing (top)
    44.6 mm1)
    Detection height
    2,400 mm
    Beam separation
    50 mm
    Optical light exit
    Flat
    Minimum detectable object (MDO), parallel beam
    55 mm2)
    Minimum detectable object (MDO), 3 x cross beam
    ≥ 29 mm2)
    Beam function
    Parallel beam
    Pin 2 (MF)
    Teach-in input
    Pin 4 (OUT)
    Object detection output = “HIGH”
    IO-Link (process data)
    QL/QintStatus, System status, Beam status
    Teach-in (default)
    Auto teach-in
    Light source
    LED
    Type of light
    Infrared light
    Number of beams
    48
    Normative reference
    EN 62471:2008-09 | IEC 62471:2006, modified
    LED risk group marking
    Free group
    Wave length
    850 nm
    Average service life
    Average service life: 100,000 h at TU= +25 °C
    Initialization time
    0.4 s ... 2 s3)
    Teach-in time
    0.75 s ... 50 s3)
    Scan time, parallel beam
    2.5 ms
    Scan time, cross beam
    4.9 ms
    Repeatability, parallel beam
    2.5 ms
    Repeatability, cross beam
    7.4 ms
    Minimum dwell time, parallel beam
    4.9 ms
    Minimum dwell time, cross beam
    9.9 ms
    Max. response time, parallel beam
    7.9 ms
    Max. response time, cross beam
    15.2 ms
    Type of synchronization
    Optical (2 beams)
    IO-Link
    ✔ , V1.1
    Data transmission rate
    COM3 (230,4 kBaud)
    Maximum cable length
    20 m
    Cycle time
    2.3 ms
    Process data length
    32 Byte
    Supply voltage UB
    DC 18 V DC ... 30 V DC1)
    Ripple
    ≤ 1.3 Vpp
    Sender
    ≤ 38.6 mA2)
    Receiver
    ≤ 67.8 mA2)
    Type
    Push-pull: PNP/NPN
    Output signal voltage HIGH/LOW
    UB-3 V/<3 V
    Output load, Inductive
    1 H
    Output load, capacitive
    100 nF
    Output current Imax.
    100 mA
    Output current, rest
    < 0.5 mA
    Number
    1
    Input signal voltage HIGH/LOW
    >15 V/<5 V
    Protection class
    III3)
    UL File No.
    NRKH.E181493 & NRKH7.E181493
    Circuit protection
    UVconnections, reverse polarity protectedOutput Q short-circuit protectedOutputs overcurrent and short-circuit protected
    Width
    11.8 mm
    Height
    2,399.2 mm
    Depth
    24.1 mm
    Connection type
    Cable with M12 male connector, 4-pin
    Cable diameter
    3.4 mm
    Conductor cross section
    0.14 mm²
    Length of cable
    150 mm
    Cable material
    PVC
    Housing
    Aluminum
    Front screen
    PMMA
    Вес
    2,960 g
    Overvoltage protection (required)
    1
    Enclosure rating
    IP651)IP67
    Ambient temperature, operation
    –30 °C ... +55 °C
    Ambient temperature, storage
    –30 °C ... +70 °C
    Ambient light immunity
    Indirect: 50,000 lx2)
    Shock resistance
    10 g, 16 ms, DIN EN 60068-2-27
    Vibration resistance
    10-150 Hz 0.5 mm, IEC 60068-2-6
    Air humidity
    ≤ 96 %, relative humidity (no condensation)
    Electromagnetic compatibility (EMC)
    EN 61000-6-2, EN 61000-6-4
    Smart Task name
    Base logics
    Logic function
    DirectANDOR
    Timer function
    DeactivatedSwitch-on delayOff delayON and OFF delayImpulse (one shot)
    Switching signal QL1
    Switching output
    Switching signal QL2
    Switching output, external input
    Device state
    Hardware error, temperature warning, operating hours warning
    Communication state
    Pin short-circuit error, invalid process data
    Status of the light signal
    Teach error, synchronization error, quality-of-run alarm
    Alarm output
    Yes
    EU declaration of conformity
    UK declaration of conformity
    ACMA declaration of conformity
    Moroccan declaration of conformity
    China RoHS
    cULus certificate
    IO-Link certificate
    Photobiological safety (IEC EN 62471)
    Information according to Art. 3 of Data Act (Regulation EU 2023/2854)
    ECLASS 5.0
    27270910
    ECLASS 5.1.4
    27270910
    ECLASS 6.0
    27270910
    ECLASS 6.2
    27270910
    ECLASS 7.0
    27270910
    ECLASS 8.0
    27270910
    ECLASS 8.1
    27270910
    ECLASS 9.0
    27270910
    ECLASS 10.0
    27270910
    ECLASS 11.0
    27270910
    ECLASS 12.0
    27270910
    ETIM 5.0
    EC002549
    ETIM 6.0
    EC002549
    ETIM 7.0
    EC002549
    ETIM 8.0
    EC002549
    UNSPSC 16.0901
    39121528
    Скачать техпаспорт

    Инструкции, CAD-модели, сертификаты и другие материалы — на сайте производителя:

    Открыть страницу товара на сайте производителя