Safety switches | safeIDS | SE1-SS1A20 | IO-Link Safety: IO-Link Safety V1.1.4 | Active sensor surface: Front | Assured switch on distance Sao: 7 mm | Connection type Detail: Plug, M12, 4-pin, A-coded | Note: The actuator has to be ordered separately. See "Accessories" for further details., Because no parameter configuration is required, there is no “dedicated tool” for this product.
System part
sensor
Sensor principle
RFID
Assured switch on distance Sao
7 mm (–10 °C ... +70 °C)1)
Assured switch off distance Sar
30 mm1)
Active sensor surfaces
1
Active sensor surface
Front
Actuation frequency
≤ 0.5 Hz
Safety integrity level
SIL 3 (IEC 61508)
Category
Category 4 (EN ISO 13849)
Performance level
PL e (EN ISO 13849)
PFHD(mean probability of a dangerous failure per hour)
0.301 x 10-91)0.418 x 10-92)
TM(mission time)
20 years (EN ISO 13849)
Type
Type 4 (EN ISO 14119)
Actuator coding level
High coding level (EN ISO 14119)3)Medium coding level (EN ISO 14119)3)Low coding level (EN ISO 14119)3)
Safe state in the event of a fault
Error display via SPDUin
Safe series connection
None, only individual wiring (with diagnostics)
Connection type
Plug, M12, 4-pin, A-coded
Long connecting cable
≤ 20 m
IO-Link Safety
✔ , IO-Link Safety V1.1.4
Data transmission rate
38.4 kBaud (COM2)
Process data length
FS-PDin: 8 bytes; FS-PDout: –
Function
Process data, diagnosis
Feature Level
a (no OSSDe support)
WCDT
≤ 406 ms
OFDT
≤ 406 ms
Display elements
LEDs
Diagnostics indicator
✔
Status display
✔
Protection class
III (IEC 61140)
Contamination rating
3 (EN 60947-1)
Usage category
DC-12 (IEC 60947-5-1)
Rated insulation voltage Ui
32 V DC
Supply voltage Vs
24 V DC (18 V DC ... 30 V DC)
Power consumption
35 mA1)
Type of output
IO-Link Safety
Response time
≤ 406 ms
Release time
≤ 100 ms
Risk time
≤ 406 ms
Switch-on time
5 s
Dimensions (W x H x D)
84 mm x 18 mm x 26 mm
Вес
44 g
Housing material
VISTAL®
Enclosure rating
IP67, IPX9K (EN 60529, ISO 20653)
Ambient operating temperature
–10 °C ... +70 °C
Storage temperature
–25 °C ... +70 °C
Vibration resistance
10 Hz ... 55 Hz, 1 mm (IEC 60068-2-6)
Shock resistance
30 g, 11 ms (IEC 60068-2-27)
EMC
EN IEC 61000-6-2EN IEC 61000-6-7EN IEC 62131-9EN IEC 61139-2
EU declaration of conformity
✔
UK declaration of conformity
✔
ACMA declaration of conformity
✔
China RoHS
✔
UK-Type-Examination approval
✔
cULus certificate
✔
TÜV approval
✔
TÜV approval annex
✔
EC-Type-Examination approval
✔
Information according to Art. 3 of Data Act (Regulation EU 2023/2854)
✔
ECLASS 5.1.4
27272403
ECLASS 6.0
27272403
ECLASS 7.0
27272403
ECLASS 8.0
27272403
ECLASS 9.0
27272403
ECLASS 10.0
27272403
ECLASS 11.0
27272403
ECLASS 12.0
27274601
ECLASS 13.0
27274601
ECLASS 14.0
27274601
ECLASS 15.0
27274601
ETIM 6.0
EC001829
ETIM 7.0
EC001829
ETIM 8.0
EC001829
ETIM 9.0
EC001829
ETIM 10.0
EC001829
UNSPSC 091201.0
39121500
UNSPSC 100501.0
39121500
UNSPSC 111201.0
39121500
UNSPSC 120901.0
39121500
UNSPSC 131201.0
39122205
UNSPSC 140801.0
39122205
UNSPSC 151101.0
39122205
UNSPSC 160901.0
39122205
UNSPSC 171001.0
39122205
UNSPSC 180801.0
39122205
UNSPSC 190501.0
39122205
UNSPSC 200601.0
39122205
UNSPSC 210901.0
39122205
UNSPSC 220601.0
39122205
UNSPSC 230701.0
39122205
UNSPSC 240301.0
39122205
UNSPSC 250901.0
39122205
UNSPSC 260801.0
39122205
Скачать техпаспорт
Инструкции, CAD-модели, сертификаты и другие материалы — на сайте производителя:
Открыть страницу товара на сайте производителя