Scanning rate/output signal frequency
20 Hz
Aperture angle
Horizontal: ≤ 180° in the application / 360° (max.) vertical: 65° (+22.5° to –42.5°)
Angular resolution
Horizontal: 0.125° (NAV plane) & 1° vertical: 2.5° (between a NAV plane and another plane) & 5°
Scanning range for 9% remission @ 100 kLux (safety-related)
0.5 m ... 4.5 m (distance relative to the front of the machine)
Scanning range for 9% remission @ 10 kLux (safety-related)
0.5 m ... 4.0 m (distance relative to the front of the machine)
Working range (sensor)
0.5 m ... 60 m
Areas of application
Outdoor area
Vehicles
Construction machinery, Agricultural machinery
Laser class
1 (EN 60825-1:2014, IEC 60825-1:2014)
Light source
Infrared (wavelength: 850 nm)
Weight
3.1 kg, APU: 2.4 kg; multiScan: 0.7 kg; no connecting cables
Supply voltage
8 V DC ... 17 V DCAdaptation to 24 V DC possible (DC-DC converter)
EMC
ISO 7637-1 & ISO 7637-2ISO 16750-2 (voltage peak)ISO 13766-2
Power consumption
≤ 80 W, Idle: ~36 W
Enclosure rating
IP65 (Industrial PC)IP69K (3D LiDAR sensors)
Functions
Output of safe distance signal via CAN busObject position in the Cartesian coordinate system
Monitored area
Rear of vehicle, front of vehicle with dynamically calculated travel path of the machine
Response time
< 300 ms1)
Detection capability
Worst-case object according to IEC 62998:Kneeling person (diameter: 190 mm, height: 1,139 mm, remission factor: 6%)For more details, see the operating instructions
CAN (APU)
1x CAN 2.0 A/B (M12 male connector)
Data transmission rate
250 kbit/sBaud rate (standard)
Ethernet (APU)
1x GbE 1000 Base-TX, 4 x GbE PoEFor service: 1 x GbE port (M12 male connector, X-coded)
Ambient operating temperature
–30 °C ... +50 °CAccessories are required for operation during maximum solar heating
Ambient temperature, storage
–40 °C ... +85 °C
Ambient light immunity
100,000 lx
Shock resistance (DIN EN 60068-2-27)
30 g11 ms1)
Items supplied
The components of the safety system are ordered via their individual part numbers. Proper use and functional scope is only assured if assembled and commissioned according to the operating instructions. The safety distance signal of the system needs to be integrated into the overall control system of the particular machine.2 x multiScan 136 (3D LiDAR sensor, variant for this safety system)1 x APU Application Processing Unit (industrial PC for data processing)2 x DC-DC voltage converter (voltage converter for on-board power)2 x Ethernet cable (data cable - sensors to IPC)
ECLASS 5.0
27279090
ECLASS 5.1.4
27279090
ECLASS 6.0
27279090
ECLASS 6.2
27279090
ECLASS 7.0
27279090
ECLASS 8.0
27279090
ECLASS 8.1
27279090
ECLASS 9.0
27279090
ECLASS 10.0
27279090
ECLASS 11.0