Safety laser scanners | S300 Mini | S32B-2011BA | Product version: S300 Mini Standard | Protective field range: 2 m | Scanning angle: 270° | Number of fields: 3
Product version
S300 Mini Standard
Application
Indoor
Protective field range
2 m
Warning field range
8 m (at 15 % reflectivity)
Distance measuring range
30 m
Type of field set
Triple field sets
Number of field sets
1
Number of fields
3
Number of monitoring cases
1
Scanning angle
270°
Resolution (can be configured)
30 mm, 40 mm, 50 mm, 70 mm
Angular resolution
0.5°
Response time
80 ms1)
Protective field supplement
100 mm
Number of multiple samplings
2 ... 16, configurable
Delay of automatic reset
2 s ... 60 s, configurable
Type
Type 3 (IEC 61496)
Safety integrity level
SIL 2 (IEC 61508)
Category
Category 3 (EN ISO 13849)
Performance level
PL d (EN ISO 13849)
PFHD(mean probability of a dangerous failure per hour)
8.0 x 10-8
TM(mission time)
20 years (EN ISO 13849)
Safe state in the event of a fault
At least one OSSD is in the OFF state.
Restart interlock
✔
Multiple sampling
✔
Contour as a reference
✔
Measured data output
None
Connection type
Cable, 250 mm, with male connector M12, 8-pin
Universal I/Os
2
External device monitoring (EDM)
11)
Reset/restart
11)
Standby
11)
Output signal switching devices (OSSDs)
2
Outputs for warning field
21)
Reset required
11)
Configuration method
PC with CDS (Configuration and Diagnostic Software)
Configuration and diagnostics interface
RS-232
Transmission rate
38.4 kBaud
Protection class
III (EN 50178, EN 60950)
Supply voltage Vs
24 V DC (16.8 V DC ... 30 V DC)
Power consumption
0.2 A1)1.35 A2)
Dimensions (W x H x D)
102 mm x 116 mm x 105 mm
Вес
0.8 kg, without connecting cables
Housing material
Aluminum die cast
Housing color
RAL 1021 (yellow), RAL 9005 (black)
Optics cover material
Polycarbonate
Optics cover surface finish
Outside with scratch-resistant coating
Enclosure rating
IP65 (EN 60529)
Ambient operating temperature
–10 °C ... +50 °C
Storage temperature
–25 °C ... +50 °C
Vibration resistance
IEC 60068-2-6, IEC 60068-2-64, IEC 60721-3-5, IEC TR 60721-4-5, IEC 61496-3
Shock resistance
IEC 60068-2-27, IEC 60721-3-5, IEC TR 60721-4-5, IEC 61496-3
Class
5M1 (IEC 60721-3-5)
Continuous shock
50 m/s², 11 ms
Type of light
Pulsed laser diode
Wave length
905 nm
Detectable remission factor
1.8 % ... > 1,000 %, reflectors
Laser class
1 (21 CFR 1040.10 and 1040.11, IEC 60825-1)
EU declaration of conformity
✔
UK declaration of conformity
✔
ACMA declaration of conformity
✔
China RoHS
✔
cULus certificate
✔
EC-Type-Examination approval
✔
China GB certificate
✔
Information according to Art. 3 of Data Act (Regulation EU 2023/2854)
✔
ECLASS 5.0
27272705
ECLASS 5.1.4
27272705
ECLASS 6.0
27272705
ECLASS 6.2
27272705
ECLASS 7.0
27272705
ECLASS 8.0
27272705
ECLASS 8.1
27272705
ECLASS 9.0
27272705
ECLASS 10.0
27272705
ECLASS 11.0
27272705
ECLASS 12.0
27272705
ETIM 5.0
EC002550
ETIM 6.0
EC002550
ETIM 7.0
EC002550
ETIM 8.0
EC002550
UNSPSC 16.0901
39121528
Скачать техпаспорт
Инструкции, CAD-модели, сертификаты и другие материалы — на сайте производителя:
Открыть страницу товара на сайте производителя