Application
Indoor, Outdoor
Variant
Standard (not pre-configured)
Measurement principle
HDDM+
Light source
Infrared (905 nm)
Laser class
1 (IEC 60825-1:2014, EN 60825-1:2014+A11:2021)
Scanning frequency
15 Hz20 Hz25 Hz30 Hz40 Hz50 HzDepends on the Dynamic Sensing Profile1)
Working range
0.05 m ... 60 m1)
At 90% remission factor and 10 klx
47 m
At 10% remission factor and 10 klx
25 m
Spot size
Divergence, typ.: 4.8 mradOn the optics cover: 8 mm
Amount of evaluated echoes
3
Connection type
1 x “Ethernet” connection, 4-pin M12 female connector, D-coded1 x “POWER” connection, 5-pin M12 plug, A-coded
System plug
Seesystem plug 2116047, Assembled to the rear
Supply voltage
9 V DC ... 30 V DC
Power consumption
Typ. 4.5 W, max. 17 W with loaded digital outputs, seesystem plug 2116047
Housing material
Aluminum with Suretec650 coating
Housing color
Anthracite gray (RAL 7016)
Optical hood
Polycarbonate, scratch-resistant coating
Enclosure rating
IP65 (IEC 60529:1989+AMD1:1999+AMD2:2013)1)IP67 (IEC 60529:1989+AMD1:1999+AMD2:2013)1)
Protection class
III (IEC 61140:2016-11)
Electrical safety
IEC 61010-1:2010-06+AMD1:2016
Kaal
220 g, without system plug
Dimensions (L x W x H)
60 mm x 60 mm x 82 mm
MTTFD
> 100 years, at 25 °C ambient temperature (EN ISO 13849-1:2015)
Digital add-ons
Dynamic Sensing Profile packageData Reduction & Data Preparation packageReliability packageMulti-echo technologyLMDscandata (data format)Reflector detectionIMU (Inertial Measurement Unit)PTP
Data output per scan segment
Segment size 30° at ≤ 25 Hz, Segment size 60° at ≥ 30 Hz
Scan/frame rate
44,161 measurement point/s ... 165,603 measurement point/s, Depends on the Dynamic Sensing Profile and number of echoes
Latency of the measurement data output
Segment size 30° at< 25 Hz: ≤ 10 ms (3 σ)Segment size 60° at ≥ 30 Hz: ≤ 15 ms (3 σ), Depends on the Dynamic Sensing Profile and number of echoes
Detectable object shape
Almost any
Systematic error
Typ. ± 20 mm1)Max. ± 30 mm
Statistical error
≤ 2 mm (0.05 m ... 5 m)2)
Integrated application
Output of measurement data2D Object Detection
Number of field sets
48 fields
Simultaneous evaluation cases
Max. 20 (The number of simultaneous evaluation cases depends on the field geometry)
Ethernet
✔ , UDP/IP Singlecast (Compact, MSGPACK), UDP/IP Multicast (Compact, MSGPACK), TCP/IP (LMDscandata)
Function
Measurement data output (distance, RSSI, time stamp, reflector mark), Field status information, DHCP, NTP, PTP
Data transmission rate
10 Mbit/s ... 100 Mbit/s, half/full-duplex
Digital inputs/outputs
3, customizable, seesystem plug 2116047
Configuration software
SOPASair (web browser)SOPAS ET (software)REST API
Driver
ROS1, ROS2, C++, Python
Remission factor
1.8 % ... > 1,000 % (Reflector)
Emitted radiation
Business and commercial areas as well as small enterprises (IEC 61000-6-8:2020 / EN IEC 61000-6-8:2020)
Electromagnetic immunity
Industrial environment (IEC 61000-6-2:2016 / EN IEC 61000-6-2:2019 / IEC 61000-6-2:2005 / EN 61000-6-2:2005 / EN 61000-6-2:2005/AC:2005)
Application areas
Earthmoving and construction machinery (ISO 13766-1)1)2)
Sine resonance scan
10 Hz ... 1,000 Hz, 1 g3)
Sine test
10 Hz ... 500 Hz, 10 g, 10 frequency cycles3)
Noise test
10 Hz ... 500 Hz, 13.5 g RMS, 5 h4)
Shock resistance
100 g, 6 ms, ± 3 single shocks/axis5)40 g, 6 ms, ± 4,000 continuous shocks/axis5)50 g, 3 ms, ± 5,000 continuous shocks/axis5)Short restriction in measurement data availability possible.
Ambient operating temperature
–33 °C ... +50 °C
Storage temperature
–40 °C ... +70 °C
Temperature change
–33 °C ... +50 °C, 10 cycles6)
Cyclical
+ 25 °C ... + 55 °C, 95 % RH, non-condensing (operation/storage/transport) (EN 60068-2-30)
Static
+ 40 °C, 93 % RH, non-condensing (operation) (EN 60068-2-78)
Operation
< 80 %, Non-condensing (EN 60068-2-30:2005)
Storage
≤ 90 %, Non-condensing (EN 60068-2-30:2005)
Ambient light immunity
100 klx, indirect
Altitude (above sea level)
< 5,000 m
Note on use
The sensor does not constitute a safety component as defined by relevant legislation on machine safety.
EU declaration of conformity
✔
UK declaration of conformity
✔
ACMA declaration of conformity
✔
Information according to Art. 3 of Data Act (Regulation EU 2023/2854)
✔