Pressure type
Compound pressure
Measuring range
–1 bar ... 0 bar
Process temperature
–30 °C ... +100 °C
Maximum ohmic load RA
4 mA ... 20 mA, 2-wire (RA≤ (L+- 8 V) / 0.02 A [Ohm]), 0 V ... 10 V, 3-wire (RA> 10 kOhm), 0 V ... 5 V, 3-wire (RA> 5 kOhm)
Output signal
4 mA ... 20 mA, 2-wire
Specialty
Free from oil and grease, vibration resistance 20 g
Process connection
G ¼ female (EN 837)
Wetted parts
Process connection: 316L stainless steelMeasuring chamber: stainless steel 316L
Internal transmission fluid
Silicone oil (only with pressure ranges < 0 bar ... 10 bar and ≤ 0 bar abs ... 25 bar abs)
Housing material
Stainless steel
Connection type
M12 round connector x 1, 4-pin
Supply voltage
8 V DC ... 30 V DC1)
Power consumption
Signal current (max. 25 mA) for current outputMax. 8 mA for voltage output signal
Electrical safety
Overvoltage protection: 32 V DC, 36 V DC with 4 mA ... 20 mAShort-circuit protection: QAtowards MReverse polarity protection: L+to MProtection class: III
Isolation voltage
500 V DC
CE-conformity
Pressure equipment directive: 2014/68/EU, EMC directive: 2014/30/EU, EN 61 326-2-3
Weight sensor
Approx. 80 g
Pressure peak dampening
Through integrated pressure port 0.6 mm or 0.3 mm for process connection G ¼ according to DIN 3852-E (0.3 mm at and above 10 bar)
Overvoltage protection
36 V DC
Non-linearity
≤ ± 0.25 %, of the span
Accuracy
≤ ± 0.5 %, of the span (including non-linearity, hysteresis, zero point and full scale error (corresponds to error of measurement as per IEC 61298-2))
Adjustment accuracy of zero signal
≤ 0.15 % of span typ., ≤ 0.4 % of span max. (with non-linerarity 0.25 %)
Hysteresis
≤ 0.16 % of the span
Non-repeatability
≤ 0.1 % of the span
Signal noise
≤ 0.3 % of the span
Long-term drift/one-year stability
≤ 0.1 % of span to IEC 61298-2
Rated temperature range
0 °C ... +80 °C
Service life
Minimum 100 Mio. load cycles
Temperature error
≤ ± 1.0% of the range, typ., ≤ ± 2.5% of the range max.
Reference conditions
Reference conditions: According to IEC 61298-1
Ambient temperature, operation
0 °C ... +80 °C
Storage temperature
–40 °C ... +70 °C
Relative humidity
45 % ... 75 %
Shock load
500 g according to IEC 60068-2-27 (mechanical shock)
Vibration load
10 g according to IEC 60068-2-6 (vibration under resonance)20 g optional
EU declaration of conformity
✔
UK declaration of conformity
✔