Pressure type
Compound pressure
Measuring range
–1 bar ... 0 bar–14.5 psi ... 0 psi
Process temperature
–20 °C ... +85 °C
Maximum ohmic load RA
4 mA ... 20 mA (RA≤ 0.5 kOhm), 0 V ... 10 V, 3-wire (RA> 10 kOhm)
Zero point adjustment
Max. + 3 % of span
Output signal
IO-Link/PNP/NPN + PNP/NPN + 4 mA ... 20 mA / 0 V ... 10 V
Rotatable housing
Display against housing with electrical connection: 330 °Housing against process connection: 320 °
Display
14-Segment LED, red, 4-digit, character height 9 mm, can be rotated electronically by 180°Update: 1,000, 500, 200, 100 ms (adjustable)
Communication interface
IO-Link
Communication Interface detail
IO-Link V1.1
Process connection
G ¼ female (EN 837)
Wetted parts
Process connection: 316L stainless steelMeasuring chamber: stainless steel 316L
Internal transmission fluid
Silicone oil (only with pressure ranges < 0 bar ... 10 bar and ≤ 0 bar abs ... 25 bar abs)
Housing material
Lower body: stainless steel 304, Plastic head: PC + ABS, Buttons: TPE-E, Display window: PC
Connection type
Round connector M12 x 1, 5-pin
Supply voltage
15 V DC ... 35 V DC
Power consumption
45 mA (for configurations without analog output signal)70 mA (for configurations with analog output signal)
Total current consumption
Max. 600 mA (including switching current)
Electrical safety
Protection class: IIIOvervoltage protection: 40 V DCShort-circuit protection: QA, Q1, Q2towards MReverse polarity protection: L+to M
Isolation voltage
500 V DC
CE-conformity
EMC Directive: 2014/30 / EU (EN 61326-1:2013; EN 61326-2-3:2013)
Ex-approvals
Pressure equipment directive: 2014/68 / EU, Hazardous materials (RoHS): 2011/65 / EU (EN 50581:2012)
Weight sensor
Approx. 220 g
Pressure peak dampening
Through integrated pressure port 0.6 mm or 0.3 mm for process connection G ¼ according to DIN 3852-E (0.3 mm at and above 10 bar)2)
Non-linearity
≤ ± 0.25 %, of span (Best Fit Straight Line, BFSL) according to IEC 61298-2
Accuracy
≤ ± 0.5 %, of the span (including non-linearity, hysteresis, zero point and full scale error (corresponds to error of measurement as per IEC 61298-2))
Setting accuracy of switching outputs
≤ ± 0.5 % of span
Long-term drift/one-year stability
≤ ± 0.1 % of span to IEC 61298-2≤ 0.2 % of the span according to IEC 61298-2 for measuring range ≤ 0.6 bar or flush-mounted membrane (0 psi ... 10 psi)
Temperature coefficient in rated temperature range
Average TC of the zero point: ≤± 0.16% of the span / 10 KAverage TC of the span ≤± 0.16% of the span / 10 K
Rated temperature range
0 °C ... +80 °C
Service life
Minimum 100 Mio. load cycles
Temperature error
≤ ± 1.0% of the range, typ., ≤ ± 2.5% of the range max.
Ambient temperature, operation
–20 °C ... +80 °C
Storage temperature
–20 °C ... +70 °C
Shock load
50 g, 6 ms according to IEC 60068-2-27 (mechanical shock)
Vibration load
20 g, 10 Hz ... 2,000 Hz (IEC 60068-2-6, at resonance)
EU declaration of conformity
✔
UK declaration of conformity
✔
Information according to Art. 3 of Data Act (Regulation EU 2023/2854)
✔