SICK

MPS-M50TUH0EA45CZZ

SKU: 1144026 Available to order
Price excluding VAT

Request a quote

    Cylinder sensors | MPS-M | MPS-M50TUH0EA45CZZ | Connection type: Cable, 4-wire, stripped, 5 m | Output function: Analog, IO-Link | Measuring range: 50 mm | Diagnostic functionality: Actuator diagnosis | Smart Sensor: Enhanced Sensing, efficient communication, diagnosis | Communication interface: IO-Link

    Cylinder type
    T-slot
    Detection zone
    0 mm ... 50 mm1)
    Cylinder types with adapter
    Profile cylinderTie rod cylinderRound body cylinderDovetail groove cylinderSMC rail CDQ2SMC rail ECDQ2
    Measuring range
    50 mm
    Housing length
    32.5 mm
    Output function
    Analog, IO-Link
    Electrical wiring
    DC 4-wire
    Analog output (voltage)
    0 V ... 10 V
    Enclosure rating
    IP67
    Diagnostic functionality
    Actuator diagnosis
    Supply voltage
    13 V DC ... 30 V DC1)
    Min. load resistance
    ≥ 10 kΩ
    Protection class
    III
    Time delay before availability
    0.15 s
    Power consumption
    ≤ 550 mW
    Required magnetic field sensitivity, typ.
    2 mT ... 20 mT2)
    Resolution, typ.
    0,01 mm3)
    Linearity error, typ.
    0.3 mm4)
    Repeat accuracy, typ.
    0.05 mm5)
    Sampling rate, typ.
    1 ms
    Reverse polarity protection
    Yes
    Short-circuit protection
    Yes
    Measuring range LED
    Yes
    Status indicator LED
    Yes
    Teach-in
    Yes
    Ambient operating temperature
    –20 °C ... +70 °C6)
    Shock and vibration resistance
    30 g, 11 ms / 10 ... 55 Hz, 1 mm
    EMC
    According to EN 60947-5-2
    Connection type
    Cable, 4-wire, stripped, 5 m
    Conductor cross section
    0.08 mm²
    Cable diameter
    Ø 2.6 mm
    Bending radius
    For flexible use > 10 x cable diameter
    Cable outlet
    Axial
    Housing
    Plastic, PA, strengthened
    Cable
    PUR
    MTTFD
    744 years
    DCavg
    0%
    TM(mission time)
    20 years
    Communication interface
    IO-Link V1.1
    Communication Interface detail
    COM3
    Cycle time
    1 ms
    Process data length
    32 Bit
    Process data structure
    Bit 0 ... 7 = switching signal Qint1 - Qint7 / AlertsBit 8 ... 15 = scalingBit 16 ... 31 = position (in x10 µm)
    Status data
    Cycle count, travel time, cylinder travel, dwell time, piston velocity
    Magnetic field strength
    2 mT ... 18 mT
    EU declaration of conformity
    UK declaration of conformity
    ACMA declaration of conformity
    China RoHS
    cULus certificate
    Information according to Art. 3 of Data Act (Regulation EU 2023/2854)
    ECLASS 5.1.4
    27270806
    ECLASS 6.0
    27270806
    ECLASS 7.0
    27270806
    ECLASS 8.0
    27270806
    ECLASS 9.0
    27270806
    ECLASS 10.0
    27270806
    ECLASS 11.0
    27270806
    ECLASS 12.0
    27274301
    ECLASS 13.0
    27274301
    ECLASS 14.0
    27274301
    ECLASS 15.0
    27274301
    ETIM 6.0
    EC002544
    ETIM 7.0
    EC002544
    ETIM 8.0
    EC002544
    ETIM 9.0
    EC002544
    ETIM 10.0
    EC002544
    UNSPSC 091201.0
    39121500
    UNSPSC 100501.0
    39121500
    UNSPSC 111201.0
    39121500
    UNSPSC 120901.0
    39121500
    UNSPSC 131201.0
    39122230
    UNSPSC 140801.0
    39122230
    UNSPSC 151101.0
    39122230
    UNSPSC 160901.0
    39122230
    UNSPSC 171001.0
    39122230
    UNSPSC 180801.0
    39122230
    UNSPSC 190501.0
    39122230
    UNSPSC 200601.0
    39122230
    UNSPSC 210901.0
    39122230
    UNSPSC 220601.0
    39122230
    UNSPSC 230701.0
    39122230
    UNSPSC 240301.0
    39122230
    UNSPSC 250901.0
    39122230
    UNSPSC 260801.0
    39122230
    Download Datasheet

    Manuals, CAD models, certificates and other materials are available on the manufacturer's website: