Cylinder sensors | MPS-C | MPS-100CLTP0 | Connection type: Cable with M8 male connector, 4-pin, 0.3 m | Output function: Analog, IO-Link | Measuring range: 100 mm | Smart Sensor: Enhanced Sensing, efficient communication, diagnosis | Communication interface: IO-Link
Cylinder type
C-slot
Cylinder types with adapter
Round body cylinderProfile cylinders and tie-rod cylindersSMC rail CDQ2SMC rail ECDQ2
Measuring range
100 mm1)
Housing length
115 mm
Switching output
Push-pull: PNP/NPN
Output function
Analog, IO-Link
Electrical wiring
DC 4-wire
Analog output (voltage)
0 V ... 10 V
Analog output (current)
4 mA ... 20 mA
Enclosure rating
IP672)
Teach-in control panel
Teaching in analog outputsSelecting the current/voltage outputInverting the analog outputTeaching in digital switching outputs
IO-Link
Teaching in 4 switching pointsPin 2 configuration (0 V–10 V, 4 mA–20 mA)Measuring range (mm) teach-in (analog output)Disabling teach-in pushbuttonTeach-in modes per output via IO-Link (cylinder switch mode, two point mode, window mode, and single point mode)
Supply voltage
12 V DC ... 30 V DC
Power consumption
42 mA, without load
Voltage drop
≤ 2 V
Continuous current Ia
≤ 100 mA1)
Max. load resistance
≤ 500 Ω Power Output, at 24 V
Min. load resistance
≥ 2 kΩ2)
Protection class
III
Time delay before availability
0.15 s
Required magnetic field sensitivity, typ.
3 mT ... 12 mT
Resolution, typ.
≥ 50 µm
Linearity error, typ.
0.3 mm3)
Repeat accuracy, typ.
0.1 mm4)
Sampling rate, typ.
1 ms
Reverse polarity protection
Yes
Short-circuit protection
Yes
Status indicator LED
Yes
Digital switching output
Yes
Teach-in
Yes
Ambient operating temperature
–20 °C ... +70 °C
Shock and vibration resistance
30 g, 11 ms / 10 ... 55 Hz, 1 mm
EMC
According to EN 60947-5-75)
Connection type
Cable with M8 male connector, 4-pin, 0.3 m
Deep-freeze property
Do not bend below 0 °C
Conductor cross section
0.08 mm²
Cable diameter
Ø 2.6 mm
Bending radius
With fixed installation > 5 x cable diameter
Cable outlet
Axial
Housing
Plastic
Cable
PUR
UL File No.
NRKH.E181493 & NRKH7.E181493
MTTFD
119 years
DCavg
0 %
TM(mission time)
20 years
Communication interface
IO-Link V1.1
Communication Interface detail
COM3
Cycle time
1 ms
Process data length
16 Bit
Process data structure
Bit 0 = switching signal QL1Bit 1 = switching signal QL2Bit 2 = switching signal QL3Bit 3 = switching signal QL4Bit 4 ... 15 = position (in 50 μm)
EU declaration of conformity
✔
UK declaration of conformity
✔
ACMA declaration of conformity
✔
China RoHS
✔
cULus certificate
✔
IO-Link certificate
✔
Information according to Art. 3 of Data Act (Regulation EU 2023/2854)
✔
ECLASS 5.0
27270104
ECLASS 5.1.4
27270104
ECLASS 6.0
27270104
ECLASS 6.2
27270104
ECLASS 7.0
27270104
ECLASS 8.0
27270104
ECLASS 8.1
27270104
ECLASS 9.0
27270104
ECLASS 10.0
27270104
ECLASS 11.0
27270104
ECLASS 12.0
27274301
ETIM 5.0
EC002544
ETIM 6.0
EC002544
ETIM 7.0
EC002544
ETIM 8.0
EC002544
UNSPSC 16.0901
39122230
Télécharger la fiche technique
Manuels, modèles CAO, certificats et autres documents — sur le site du fabricant :