Automation light grids | MLG-2 WebChecker | MLG05W-0441R12501 | Device version: Web guiding | Inputs/outputs: 4 x Q (IO-Link) | Option: None | Beam separation: 5 mm | Operating range: 2.5 m | Total measuring field width: 1,345 mm | Measuring field width detail (connection side/medium range/head side): 595 mm / 605 mm / 145 mm | Length of cable: 0.22 m, 0.27 m, 0.19 m | Response time: 30.8 ms | Software feature (default setting - see technical data/features): 01
Device version
Web guiding
Sensor principle
Sender/receiver
Minimum object length
4 mm1)
Beam separation
5 mm
Resolution
0.1 mm
Repeatability
6 µm2)
Accuracy
± 0.3 mm
Type of synchronization
Cable
Number of beams
150
Total measuring field width
1,345 mm
Measuring field width (connection side)
595 mm
Blind zone (medium range)
605 mm
Measuring field width (head side)
145 mm
Q1/C
Alarm, general
Q2
Standard teach-in
Q3
Edge position 1
Q4
Edge position 10
Application
Standard mode
Included with delivery
1 × sender1 × receiver4/6 xQuickFix brackets(6 x QuickFix brackets for monitoring heights above 2 m)1 × Quick Start Guide
Light source
LED, Infrared light
Wave length
850 nm
Supply voltage Vs
DC 19.2 V ... 28.8 V1)
Power consumption sender
62.5 mA2)
Power consumption receiver
150 mA2)
Ripple
< 5 Vpp
Output current Imax.
100 mA
Output load, capacitive
100 nF
Output load, Inductive
1 H
Initialization time
< 1 s
Switching output
Push-pull: PNP/NPN
Dimensions (W x H x D)
34 mm x 1,429.4 mm x 30.6 mm
Connection type
Plug, M12, 5-pin, 0.22 mMale connector M12, 8-pin, 0.27 mM12 female connector, 4-pin, D-coded, 0.19 m
Housing material
Aluminum
Display
LED
Enclosure rating
IP65, IP673)
Circuit protection
UVconnections, reverse polarity protectedOutput Q short-circuit protectedInterference pulse suppression
Protection class
III
Poids
2.959 kg
Front screen
PMMA
Option
None
UL File No.
NRKH.E181493
Maximum range
3.5 m1)
Minimum range
≥ 0.2 m
Operating range
2.5 m
Response time
30.8 ms2)
IO-Link
✔ , IO-Link V1.1
Data transmission rate
230,4 kbit/s (COM3)
Maximum cable length
20 m
Cycle time
3 ms
VendorID
26
DeviceID HEX
80022F
DeviceID DEC
8389167
Process data length
32 Byte (TYPE_2_V)1)
Inputs/outputs
4 x Q (IO-Link)
Digital output
Q1... Q4
Digital input
Q2, Q3, Q4
Number
3
Shock resistance
Continuous shocks 10 g, 16 ms, 1000 shocksSingle shocks 15 g, 11 ms 3 per axle
Vibration resistance
Sinusoidal oscillation 10-150 Hz 5 g
Ambient light immunity
100,000 lx
Ambient operating temperature
–30 °C ... +55 °C
Ambient temperature, storage
–40 °C ... +70 °C
EU declaration of conformity
✔
UK declaration of conformity
✔
ACMA declaration of conformity
✔
Moroccan declaration of conformity
✔
China RoHS
✔
cULus certificate
✔
IO-Link certificate
✔
Photobiological safety (IEC EN 62471)
✔
Information according to Art. 3 of Data Act (Regulation EU 2023/2854)
✔
Télécharger la fiche technique
Manuels, modèles CAO, certificats et autres documents — sur le site du fabricant :
Ouvrir la page produit sur le site du fabricant