SICK

MAX48N-12A10BE1100

SKU: 1219742 Disponible sur commande
Prix hors TVA

Demander un devis

    Linear encoders | MAX | MAX48N-12A10BE1100 | Type: 48 mm 48f7 for IN cylinder mounting – cylinder bore hole 48H8 | Cable connection direction: Radial | Pipe diameter / Damping zone / End cap: 10 mm / 30 mm / Flat | Supply voltage: 24 V DC (8 ... 32 V DC) | Communication interface: Analog / Current | Connection type: Male connector, M12 type S (20x20 mm), 4-pin | Measuring range: 0 mm ... 1,100 mm

    Items supplied
    Accessories not included with delivery, please order separately.
    MTTFD(mean time to dangerous failure)
    69 years (EN ISO 13849-1)1)
    Type
    48 mm installation housing – IN cylinder mounting
    Pressure pipe/End cap
    10 mm / Flat
    Direction of connection
    Radial
    Measured values
    Positioning
    Position (F.S.)
    0 mm ... 1,100 mm1)
    Null zone
    30 mm
    Damping zone
    30 mm
    Fluid temperature
    –30 °C ... +95 °C2)
    Air humidity
    90 % (Condensation not permitted)
    Switch-on time
    < 250 ms
    Switch-on current
    Typ. 5.0 A / 50 µs
    Measuring frequency (internal)
    2 ms
    Transmission rate (cycle time)
    Steady
    Setpoint tolerance
    ≤ ± 1 mm
    Hysteresis
    ± 0,1 mm
    Repeatability
    Typ. ± 0.2 mm
    Linearity
    Typ. ± 0.25 mm (measuring range 50 to 500 mm)3)
    Warming up phase
    Typ. ≤ ± 0.25 mm (2 min)
    In the operational status
    Typ. ± 0.25 mm (measuring range 50 to 500 mm)3)
    Communication interface
    Analog
    Communication Interface detail
    Current
    Current output
    4 mA ... 20 mA
    Connection type
    Male connector, M12 type S (20x20 mm), 4-pin
    PIN assignment
    1=V DC; 2=SIG; 3=GND; 4=n.c.
    Supply voltage
    24 V DC (8 ... 32 V DC)
    Residual ripple
    < 1% S-S
    Power consumption
    ≤ 1.25 W
    Current consumption
    ≤ 50 mA
    Load resistance
    100 Ω ≤ RL ≤ 500 Ω
    Overvoltage protection during power-up (60 s)
    ≤ 36 V at all poles during power-up (60 s)≤ 48 V To GND during power-up (60 s)
    Reverse polarity protection
    ≤ 36 V (at all poles) (ISO 16750-2)
    Insulation resistance
    Riso ≥ 10 MΩ, 60 s (ISO 16750-2)
    Dielectric strength
    500 V DC, 0 V DC (60 s) to housing (RISO≥ 1 MΩ) (ISO 16750-2)
    Short-circuit protection
    VS– GND on housing
    Ø pressure pipe
    10 mm
    Ø O-ring
    40.87 mm x 3.53 mm
    Ø support ring
    42.6 mm x 48 mm x 1.4 mm
    Wire length
    100 mm
    Pressure pipe
    Stainless steel 1.4404, AISI 316L
    O-ring
    NBR 70
    Support ring
    PTFE
    M12 flange
    Nickel-plated brass with O-ring (NBR)
    Strands
    PVC
    EMC
    EU Directive 2014/30 / EU CE marking
    Generic standards
    EN 61000-6-2/61000-6-3
    Agricultural and forestry machinery
    EN ISO 14982
    Transient pulses
    ISO 7637-2/ISO 16750-2
    ESD (air and contact discharge)
    ISO 61000-4-2 / ISO 10605
    Sine
    20 g (sine) / 55 ... 2,000 Hz / 3x24 h (IEC 60068-2-6 Fc)
    Sine over noise
    18 g (r.m.s) / 10 ... 2,000 Hz / 3x36 h (IEC 60068-2-80 Fi)
    Broadband noise (resonance peaks removed)
    20 g (r.m.s) / 10 ... 2,000 Hz / 3x48 h (IEC 60068-2-64 Fh)
    Operating pressure PN
    400 bar
    Overload pressure Pmax= PNx 1.2
    480 bar
    Test pressure Pstat= PNx 1.5
    600 bar
    Storage
    –20 °C ... +65 °C1)
    Operation (electronics)
    –40 °C ... +105 °C2)
    Maximum air humidity
    90 % (Condensation not permitted)
    Housing
    IP67 (EN 60529)
    M12 male connector
    IP69K (ISO 20653)3)
    EU declaration of conformity
    UK declaration of conformity
    ACMA declaration of conformity
    Moroccan declaration of conformity
    China RoHS
    Information according to Art. 3 of Data Act (Regulation EU 2023/2854)
    ECLASS 5.0
    27270705
    ECLASS 5.1.4
    27270705
    ECLASS 6.0
    27270705
    ECLASS 6.2
    27270705
    ECLASS 7.0
    27270705
    ECLASS 8.0
    27270705
    ECLASS 8.1
    27270705
    ECLASS 9.0
    27270705
    ECLASS 10.0
    27270705
    ECLASS 11.0
    27270705
    ECLASS 12.0
    27274304
    ETIM 5.0
    EC002544
    ETIM 6.0
    EC002544
    ETIM 7.0
    EC002544
    ETIM 8.0
    EC002544
    UNSPSC 16.0901
    41111613
    Télécharger la fiche technique

    Manuels, modèles CAO, certificats et autres documents — sur le site du fabricant :

    Ouvrir la page produit sur le site du fabricant