Linear encoders | MAX | MAX48A-32V10K10600 | Type: Ø 48 mm 48f7 for IN cylinder mounting – cylinder bore hole 48H8 | Pipe diameter / Damping zone / End cap: 63 mm / Flat | Supply voltage: 24 V DC (8 ... 32 V DC) | Communication interface: Analog / Voltage | Connection type: Connecting cable, 3-wire, 300 mm | Measuring range: 0 mm ... 600 mm | Output signal: 0.5 V DC ... 4.5 V DC
Items supplied
Accessories not included with delivery, please order separately.
MTTFD(mean time to dangerous failure)
69 years (EN ISO 13849-1)1)
Pressure pipe/End cap
Flat
Measured values
Positioning
Position (F.S.)
0 mm ... 600 mm1)
Null zone
30 mm
Damping zone
63 mm
Fluid temperature
–30 °C ... +95 °C2)
Air humidity
90 % (Condensation not permitted)
Switch-on time
< 250 ms
Switch-on current
Typ. 5.0 A / 50 µs
Measuring frequency (internal)
2 ms
Transmission rate (cycle time)
Steady
Setpoint tolerance
≤ ± 1 mm
Hysteresis
± 0,1 mm
Repeatability
Typ. ± 0.2 mm
Communication interface
Analog
Communication Interface detail
Voltage
Voltage output
0.5 V DC ... 4.5 V DC
Connection type
Connecting cable, 3-wire, 300 mm
Supply voltage
24 V DC (8 ... 32 V DC)
Residual ripple
< 1% S-S
Power consumption
≤ 0.75 W
Current consumption
≤ 30 mA
Load resistance
RL≥ 10 kΩ
Overvoltage protection during power-up (60 s)
≤ 36 V at all poles during power-up (60 s)≤ 48 V To GND during power-up (60 s)
Reverse polarity protection
≤ 36 V (at all poles) (ISO 16750-2)
Insulation resistance
Riso≥ 10 MΩ (ISO 16750-2)
Dielectric strength
500 V DC, 0 V DC (60 s) to housing (RISO≥ 1 MΩ)
Short-circuit protection
VS– GND on housing
Ø connecting cable
Ø 5.0 mm; 3 x 0.38 mm² (AWG22), stripped
Length of cable
300 mm
Housing
Stainless steel 1.4305 (AISI 303)
Pressure pipe
Stainless steel 1.4404, AISI 316L
O-ring
NBR 70
Support ring
PTFE
Sheath
PUR
EMC
EU Directive 2014/30
ESD (air and contact discharge)
ISO 61000-4-2: 2009 / ISO 10605: 2008
Sine
20 g (sine) / 55 ... 2,000 Hz / 3x24 h (IEC 60068-2-6 Fc)
Sine over noise
18 g (r.m.s) / 10 ... 2,000 Hz / 3x36 h (IEC 60068-2-80 Fi)
Operating pressure PN
400 bar
Overload pressure Pmax= PNx 1.2
480 bar
Storage
–20 °C ... +65 °C1)
Operation (electronics)
–40 °C ... +105 °C2)
Maximum air humidity
90 % (Condensation not permitted)
EU declaration of conformity
✔
UK declaration of conformity
✔
ACMA declaration of conformity
✔
Moroccan declaration of conformity
✔
China RoHS
✔
Information according to Art. 3 of Data Act (Regulation EU 2023/2854)
✔
ECLASS 5.0
27270705
ECLASS 5.1.4
27270705
ECLASS 6.0
27270705
ECLASS 6.2
27270705
ECLASS 7.0
27270705
ECLASS 8.0
27270705
ECLASS 8.1
27270705
ECLASS 9.0
27270705
ECLASS 10.0
27270705
ECLASS 11.0
27270705
ECLASS 12.0
27274304
ETIM 5.0
EC002544
ETIM 6.0
EC002544
ETIM 7.0
EC002544
ETIM 8.0
EC002544
UNSPSC 16.0901
41111613