Linear encoders | MAX | MAX48A-12C7FSC0500 | Type: 48 mm 48f7 for IN cylinder mounting – cylinder bore hole 48H8 | Cable connection direction: Axial | Pipe diameter / Damping zone / End cap: 10 mm / 30 mm / Flat | Supply voltage: 24 V DC (8 ... 32 V DC) | Communication interface: CANopen | Connection type: Male connector, M12 type L (24x24 mm), 5-pin | Measuring range: 0 mm ... 500 mm
Items supplied
Accessories not included with delivery, please order separately.
MTTFD(mean time to dangerous failure)
69 years (EN ISO 13849-1)1)
Type
48 mm installation housing – IN cylinder mounting
Pressure pipe/End cap
10 mm / Flat
Direction of connection
Axial
Measured values
Positioning, speed
Position (F.S.)
0 mm ... 500 mm1)
Speed
0 … 1,000 mm/s
Null zone
30 mm
Damping zone
30 mm
Fluid temperature
–30 °C ... +95 °C2)
Air humidity
90 % (Condensation not permitted)
Switch-on time
< 250 ms
Switch-on current
Typ. 5.0 A / 50 µs
Measuring frequency (internal)
1 ms
Transmission rate (cycle time)
CANopen (0 ... 65,535 ms), factory setting: 0 ms (transmission stopped)
Hysteresis
± 0,1 mm
Repeatability
Typ. ± 0.2 mm
Linearity
Typ. ± 0.25 mm (measuring range 50 to 500 mm)3)
Warming up phase
Typ. ≤ ± 0.25 mm (2 min)
In the operational status
Typ. ± 0.25 mm (measuring range 50 to 500 mm)3)
Communication interface
CANopen
Bus protocol
CANopen CiA DS-301
Device profile
CANopen CiA DS-406
Baud rate
250 kbit/s
Node ID
7F
Connection type
Male connector, M12 type L (24x24 mm), 5-pin
PIN assignment
1=V DC; 2=n.c.; 3=GND; 4=CAN_H; 5=CAN_L
Supply voltage
24 V DC (8 ... 32 V DC)
Residual ripple
< 1% S-S
Power consumption
≤ 0.75 W
Current consumption
≤ 30 mA
Bus termination (external)
120 Ω
Overvoltage protection during power-up (60 s)
≤ 36 V at all poles during power-up (60 s)≤ 48 V To GND during power-up (60 s)
Reverse polarity protection
≤ 36 V (at all poles) (ISO 16750-2)
Insulation resistance
Riso ≥ 10 MΩ, 60 s (ISO 16750-2)
Dielectric strength
500 V DC, 0 V DC (60 s) to housing (RISO≥ 1 MΩ) (ISO 16750-2)
Short-circuit protection
VS– GND on housing
Ø pressure pipe
10 mm
Ø O-ring
40.87 mm x 3.53 mm
Ø support ring
42.6 mm x 48 mm x 1.4 mm
Wire length
80 mm
Pressure pipe
Stainless steel 1.4404, AISI 316L
O-ring
NBR 70
Support ring
PTFE
M12 flange
Nickel-plated brass with O-ring (NBR)
Strands
PVC
EMC
EU Directive 2014/30 / EU CE marking
Generic standards
EN 61000-6-2/61000-6-3
Agricultural and forestry machinery
EN ISO 14982
Transient pulses
ISO 7637-2/ISO 16750-2
ESD (air and contact discharge)
ISO 61000-4-2 / ISO 10605
Sine
20 g (sine) / 55 ... 2,000 Hz / 3x24 h (IEC 60068-2-6 Fc)
Sine over noise
18 g (r.m.s) / 10 ... 2,000 Hz / 3x36 h (IEC 60068-2-80 Fi)
Broadband noise (resonance peaks removed)
20 g (r.m.s) / 10 ... 2,000 Hz / 3x48 h (IEC 60068-2-64 Fh)
Operating pressure PN
400 bar
Overload pressure Pmax= PNx 1.2
480 bar
Test pressure Pstat= PNx 1.5
600 bar
Storage
–20 °C ... +65 °C1)
Operation (electronics)
–40 °C ... +105 °C2)
Maximum air humidity
90 % (Condensation not permitted)
Housing
IP67 (EN 60529)
M12 male connector
IP69K (ISO 20653)3)
EU declaration of conformity
✔
UK declaration of conformity
✔
ACMA declaration of conformity
✔
Moroccan declaration of conformity
✔
China RoHS
✔
Information according to Art. 3 of Data Act (Regulation EU 2023/2854)
✔
ECLASS 5.0
27270705
ECLASS 5.1.4
27270705
ECLASS 6.0
27270705
ECLASS 6.2
27270705
ECLASS 7.0
27270705
ECLASS 8.0
27270705
ECLASS 8.1
27270705
ECLASS 9.0
27270705
ECLASS 10.0
27270705
ECLASS 11.0
27270705
ECLASS 12.0
27274304
ETIM 5.0
EC002544
ETIM 6.0
EC002544
ETIM 7.0
EC002544
ETIM 8.0
EC002544
UNSPSC 16.0901
41111613
Download Datasheet
Manuals, CAD models, certificates and other materials are available on the manufacturer's website:
Open product page on manufacturer's website
