Linear encoders | MAX | MAX30N-72PBDBE0500 | Type: 30 mm 31f7 for IN cylinder mounting – cylinder bore hole 31H8 | Cable connection direction: Radial | Pipe diameter / Damping zone / End cap: 7 mm / 30 mm / Flat | Supply voltage: 24 V DC (8 ... 32 V DC) | Communication interface: PWM | Connection type: Male connector, M12 type S (20x20 mm), 4-pin | Measuring range: 0 mm ... 500 mm
Items supplied
Accessories not included with delivery, please order separately.
MTTFD(mean time to dangerous failure)
69 years (EN ISO 13849-1)1)
Type
30 mm installation housing – IN cylinder mounting
Pressure pipe/End cap
7 mm / Flat
Direction of connection
Radial
Measured values
Positioning
Position (F.S.)
0 mm ... 500 mm1)
Null zone
21.5 mm
Damping zone
30 mm
Fluid temperature
–30 °C ... +95 °C2)
Air humidity
90 % (Condensation not permitted)
Switch-on time
< 250 ms
Switch-on current
5,0 A/ 50 µs
Measuring frequency (internal)
2 ms
Transmission rate (cycle time)
Type-dependent, according to PWM frequency
Setpoint tolerance
≤ ± 1 mm
Hysteresis
± 0,1 mm
Repeatability
Typ. ± 0.2 mm
Linearity
Typ. ± 0.25 mm (measuring range 50 to 500 mm)3)
Warming up phase
Typ. ≤ ± 0.25 mm (2 min)
In the operational status
Typ. ± 0.25 mm (measuring range 50 to 500 mm)3)
Communication interface
PWM
Puls width
10% ... 90%
Frequency
250 Hz
Connection type
Male connector, M12 type S (20x20 mm), 4-pin
PIN assignment
1=V DC; 2=SIG; 3=GND; 4=n.c.
Supply voltage
24 V DC (8 ... 32 V DC)
Residual ripple
< 1% S-S
Power consumption
≤ 0.75 W
Current consumption
≤ 30 mA
Overvoltage protection during power-up (60 s)
≤ 36 V at all poles during power-up (60 s)≤ 48 V To GND during power-up (60 s)
Reverse polarity protection
≤ 36 V (at all poles) (ISO 16750-2)
Insulation resistance
Riso ≥ 10 MΩ, 60 s (ISO 16750-2)
Dielectric strength
500 V DC, 0 V DC (60 s) to housing (RISO≥ 1 MΩ) (ISO 16750-2)
Short-circuit protection
VS– GND on housing
Ø pressure pipe
7 mm
Ø O-ring
24.99 mm x 3.53 mm
Ø support ring
31 mm x 25.8 mm x 1.4 mm
Wire length
100 mm
Pressure pipe
Stainless steel 1.4404, AISI 316L
O-ring
NBR 70
Support ring
PTFE
M12 flange
Nickel-plated brass with O-ring (NBR)
Strands
PVC
EMC
EU Directive 2014/30 / EU CE marking
Generic standards
EN 61000-6-2/61000-6-3
Agricultural and forestry machinery
EN ISO 14982
Transient pulses
ISO 7637-2/ISO 16750-2
ESD (air and contact discharge)
ISO 61000-4-2 / ISO 10605
Sine
15 g, 24 h / axis, 55 ... 2.000 Hz (IEC 60068-2-6)
Sine over noise
13 g (r.m.s), 36 h / axis, 10 ... 2.000 Hz (IEC 60068-2-80)
Broadband noise (resonance peaks removed)
15 g (r.m.s), 48 h / axis, 10 ... 2.000 Hz (IEC 60068-2-64)
Operating pressure PN
320 bar
Overload pressure Pmax= PNx 1.2
380 bar
Test pressure Pstat= PNx 1.5
480 bar
Storage
–20 °C ... +65 °C1)
Operation (electronics)
–40 °C ... +105 °C2)
Maximum air humidity
90 % (Condensation not permitted)
Housing
IP67 (EN 60529)
M12 male connector
IP69K (ISO 20653)3)
EU declaration of conformity
✔
UK declaration of conformity
✔
ACMA declaration of conformity
✔
Moroccan declaration of conformity
✔
China RoHS
✔
Information according to Art. 3 of Data Act (Regulation EU 2023/2854)
✔
ECLASS 5.0
27270705
ECLASS 5.1.4
27270705
ECLASS 6.0
27270705
ECLASS 6.2
27270705
ECLASS 7.0
27270705
ECLASS 8.0
27270705
ECLASS 8.1
27270705
ECLASS 9.0
27270705
ECLASS 10.0
27270705
ECLASS 11.0
27270705
ECLASS 12.0
27274304
ETIM 5.0
EC002544
ETIM 6.0
EC002544
ETIM 7.0
EC002544
ETIM 8.0
EC002544
UNSPSC 16.0901
41111613
Скачать техпаспорт
Инструкции, CAD-модели, сертификаты и другие материалы — на сайте производителя:
Открыть страницу товара на сайте производителя