Product version
deTem4 LT Muting A/P
Application
Normal industrial environment
Functional principle
Active/passive
Items supplied
Active unitSafety instructionMounting instructionsOperating instructions for download
Safety integrity level
SIL 3 (IEC 61508)
Category
Category 4 (ISO 13849-1)
Performance level
PL e (ISO 13849-1)
PFHD(mean probability of a dangerous failure per hour)
6.8 × 10-9
TM(mission time)
20 years (ISO 13849-1)
Safe state in the event of a fault
At least one OSSD is in the OFF state.
Differentiation between man and material (muting)
✔
Monitoring of total muting time
✔
System connection
Male connector M12, 8-pin
Connection for muting sensors
2 × female connector, M12, 5-pin
Connection for reset/override pushbutton
Female connector M12, 5-pin
Configuration method
Hard wired
Alignment aid
Alignment quality via diagnostic LEDs
End cap with integrated LED
✔
Near Field Communication (NFC)
✔
Protection class
III (IEC 61140)1)
Supply voltage VS
24 V DC (19.2 V DC ... 28.8 V DC)2)
Power consumption typical
7 W (DC)
Output signal switching devices (OSSDs)
2 PNP semiconductors, short-circuit protected, cross-circuit monitored4)
ON state, switching voltage HIGH
24 V DC (VS– 2.25 V DC ... VS)
OFF state, switching voltage LOW
≤ 2 V DC
Current-carrying capacity per OSSD
≤ 500 mA
Application diagnostic output (ADO)
PNP semiconductor, short-circuit protected4)
Output voltage HIGH (active)
≥ Vs– 3 V
Output voltage LOW (deactivated)
High resistance
Dimensions
See dimensional drawing
Housing
Aluminum extruded profile
Front screen
Polycarbonate, scratch-resistant coating
Enclosure rating
IP65 (IEC 60529)IP67 (IEC 60529)
Ambient operating temperature
–30 °C ... +55 °C
Storage temperature
–30 °C ... +70 °C
Air humidity
15 % ... 95 %, Non-condensing
Vibration resistance
5 … 150 Hz, 3,5 mm / 1 g (EN 60068-2-6)
Shock resistance
15 g / 6 ms (EN 60068-2-27)
Class
3M4 (IEC TR 60721-4-3)
Type of light
Near-infrared (NIR), invisible
EU declaration of conformity
✔
UK declaration of conformity
✔
ACMA declaration of conformity
✔
Moroccan declaration of conformity
✔
EC-Type-Examination approval
✔
Information according to Art. 3 of Data Act (Regulation EU 2023/2854)
✔