SICK

LMS4124R-13000S01

SKU: 1116198 Saadaval tellimisel
Hind käibemaksuta

Küsi pakkumist

    LiDAR sensors | LMS4000 | LMS4124R-13000S01 | Working range: 0.5 m ... 5.5 m | Enclosure rating: IP65 | Color: Light blue (RAL 5012) | Integrated application: Output of measurement data | Connection type: 1 x M12, 5-pin plug (Power + I/O + Sync), 1 x M12, 8-pin female connector (Ethernet), 1 x M12, 5-pin female connector (Encoder + I/O) | Scanning frequency: 600 Hz

    Application
    Indoor
    Reading field
    Front
    Light source
    Visible red light (660 nm)
    Laser class
    2 (IEC 60825-1:2014, EN 60825-1:2014)
    Scanning frequency
    600 Hz
    Horizontal
    0.0833°
    Working range
    0.5 m ... 5.5 m
    At 2% remission factor
    3 m
    At 3.5% remission factor
    3 m
    At 10% remission factor
    4 m
    Connection type
    1 x M12, 5-pin plug (Power + I/O + Sync)1 x M12, 8-pin female connector (Ethernet)1 x M12, 5-pin female connector (Encoder + I/O)
    Supply voltage
    24 V DC, ± 25 %
    Power consumption
    ≤ 16 W, start-up phase max. 29 W
    Output current
    ≤ 100 mA
    Housing material
    Aluminum die cast
    Housing color
    Light blue (RAL 5012)
    Enclosure rating
    IP65
    Protection class
    III
    Electrical safety
    IEC 61010-1:2011
    Kaal
    3.7 kg
    Dimensions (L x W x H)
    397 mm x 370 mm x 107 mm
    MTBF
    80 years
    MTTFD
    > 100 years
    Scan/frame rate
    504,600 measurement point/s
    Response time
    ≥ 4.8 ms
    Detectable object shape
    Almost any
    Systematic error
    ± 1 mm (0.7 m ... 3 m)1)± 4 mm (0.5 m ... 0.7 m; 3 m ... 5.5 m)1)
    Statistical error
    1.5 mm (0.7 m ... 3 m)1)9 mm (0.5 m ... 0.7 m; 3 m ... 5.5 m)1)
    Integrated application
    Output of measurement data
    Filter
    Rectangular filterEdge filterMedian filterGloss compensationAverage filter
    Ethernet
    ✔ , TCP/IP, UDP/IP
    Function
    Measurement data output (distance, RSSI, angle)
    Data transmission rate
    100 Mbit/s ... 1,000 Mbit/s, half/full-duplex
    Inputs
    2
    Outputs
    3
    Encoder inputs
    2 (phase A, phase B)
    Synchronization inputs/outputs
    One (master / slave)
    Optical indicators
    4 LEDs
    Configuration software
    SOPAS ET
    Maximum encoder frequency
    Max. 50 kHz
    Remission factor
    2 % ... 200 %
    Electromagnetic compatibility (EMC)
    EN 61000-6-3:2007+A1:2011 / IEC 61000-6-3:2006+AMD1:2010
    Vibration resistance
    EN 60068-2-6:2007
    Shock resistance
    EN 60068-2-27:2008
    Ambient operating temperature
    –10 °C ... +50 °C1)
    Storage temperature
    –20 °C ... +70 °C
    Permissible relative humidity
    ≤ 90 %, Non-condensing
    Ambient light immunity
    2,000 lx
    Note on use
    The sensor does not constitute a safety component as defined by relevant legislation on machine safety.If the working range is exceeded or undercut, random measuring points are projected into the affected angular ranges, although no objects are present there. Beam separation for limiting detection can prevent this effect.
    EU declaration of conformity
    UK declaration of conformity
    ACMA declaration of conformity
    China RoHS
    cTUVus certificate
    ECLASS 5.0
    27270990
    ECLASS 5.1.4
    27270990
    ECLASS 6.0
    27270913
    ECLASS 6.2
    27270913
    ECLASS 7.0
    27270913
    ECLASS 8.0
    27270913
    ECLASS 8.1
    27270913
    ECLASS 9.0
    27270913
    ECLASS 10.0
    27270913
    ECLASS 11.0
    27270913
    ECLASS 12.0
    27270913
    ETIM 5.0
    EC002550
    ETIM 6.0
    EC002550
    ETIM 7.0
    EC002550
    ETIM 8.0
    EC002550
    UNSPSC 16.0901
    41111615
    Lae alla teabeleht

    Juhendid, CAD-mudelid, sertifikaadid ja muud materjalid on tootja veebisaidil: