LiDAR sensors | LMS5xx | LMS251-11100 Lite | Working range: 0 m ... 65 m | Enclosure rating: IP65, IP67 | Color: Gray (RAL 7032) | Integrated application: Field evaluation, output of measurement data | Connection type: 3 x M12 round connector | Scanning frequency: 75 Hz
Application
Outdoor, Indoor
Variant
Lite
Light source
Infrared (905 nm, ± 10 nm)
Laser class
1 (EN/IEC 60825-1:2014 (Ed.3), EN/IEC 60825-1:2007 (Ed.2) CAN/CSA-E60825-1:2015-11 (Ed.3))
Scanning frequency
75 Hz
Horizontal
0.5°
Scan field flatness
Scan field flatness combined: ± 0.72°Typical conical error: 1 sigma value - 0.11° ± 0.1°Typical tilt: 1 sigma value + 0.15° ± 0.08°
Heating
Self-heating with additional integrated heating
Working range
0 m ... 65 m
Amount of evaluated echoes
1
Connection type
3 x M12 round connector
Supply voltage
24 V DC, ± 20 %
Power consumption
22 W, + 55 W heating (typical)
Housing material
AlSi12
Housing color
Gray (RAL 7032)
Window material
Polycarbonate, scratch-resistant coating
Enclosure rating
IP65 (EN 60529, Section 14.2.7)IP67 (EN 60529, Section 14.2.7)
Protection class
III (IEC 61140:2016-11)
Weight
3.7 kg
Dimensions (L x W x H)
160 mm x 155 mm x 185 mm
MTBF
> 100 years
MTTFD
> 100 years
Response time
≥ 13 ms
Detectable object shape
Almost any
Integrated application
Field evaluationOutput of measurement data
Number of field sets
4 fields
Simultaneous evaluation cases
4
Filter
Echo filterFog filterParticle filterAverage filterGlare filter
Serial
✔ , RS-232, RS-422
Data transmission rate
9.6 kBaud ... 500 kBaud
USB
✔
Remark
Mini-USB
Function
Service interface
Digital inputs
2 (digital)
Digital outputs
3 (digital)
Optical indicators
5 LEDs (Additional 7-segment display)
Object remission
2 % ... > 1,000 % (reflectors)
Emitted radiation
Industrial environment (IEC 61000-6-3:2020 / EN IEC 61000-6-3:2007+A1:2011)
Electromagnetic immunity
Industrial environment (IEC 61000-6-2:2016 / EN IEC 61000-6-2:2019)
Sine test
10 Hz ... 150 Hz, Amplitude 0.35 mm to 5 g, 20 cycles1)
Shock resistance
15 g, 11 ms, 6 single shocks/axis2)10 g, 16 ms, 1,000 continuous shocks/axis2)
Impact resistance
IK05, IK06, IK07 (DIN EN 50102:09-1997)
Ambient operating temperature
–30 °C ... +50 °C
Storage temperature
–40 °C ... +70 °C
Ambient light immunity
70,000 lx
Note on use
The sensor does not constitute a safety component as defined by relevant legislation on machine safety.
cTUVus certificate
✔
ECLASS 5.0
27270990
ECLASS 5.1.4
27270990
ECLASS 6.0
27270913
ECLASS 6.2
27270913
ECLASS 7.0
27270913
ECLASS 8.0
27270913
ECLASS 8.1
27270913
ECLASS 9.0
27270913
ECLASS 10.0
27270913
ECLASS 11.0
27270913
ECLASS 12.0
27270913
ETIM 5.0
EC002550
ETIM 6.0
EC002550
ETIM 7.0
EC002550
ETIM 8.0
EC002550
UNSPSC 16.0901
41111615
Download Datasheet
Manuals, CAD models, certificates and other materials are available on the manufacturer's website:
Open product page on manufacturer's website