SICK

LMS251-11100 Lite

SKU: 1057767 Discontinued
Price excluding VAT

Request a quote

    LiDAR sensors | LMS5xx | LMS251-11100 Lite | Working range: 0 m ... 65 m | Enclosure rating: IP65, IP67 | Color: Gray (RAL 7032) | Integrated application: Field evaluation, output of measurement data | Connection type: 3 x M12 round connector | Scanning frequency: 75 Hz

    Application
    Outdoor, Indoor
    Variant
    Lite
    Light source
    Infrared (905 nm, ± 10 nm)
    Laser class
    1 (EN/IEC 60825-1:2014 (Ed.3), EN/IEC 60825-1:2007 (Ed.2) CAN/CSA-E60825-1:2015-11 (Ed.3))
    Scanning frequency
    75 Hz
    Horizontal
    0.5°
    Scan field flatness
    Scan field flatness combined: ± 0.72°Typical conical error: 1 sigma value - 0.11° ± 0.1°Typical tilt: 1 sigma value + 0.15° ± 0.08°
    Heating
    Self-heating with additional integrated heating
    Working range
    0 m ... 65 m
    Amount of evaluated echoes
    1
    Connection type
    3 x M12 round connector
    Supply voltage
    24 V DC, ± 20 %
    Power consumption
    22 W, + 55 W heating (typical)
    Housing material
    AlSi12
    Housing color
    Gray (RAL 7032)
    Window material
    Polycarbonate, scratch-resistant coating
    Enclosure rating
    IP65 (EN 60529, Section 14.2.7)IP67 (EN 60529, Section 14.2.7)
    Protection class
    III (IEC 61140:2016-11)
    Weight
    3.7 kg
    Dimensions (L x W x H)
    160 mm x 155 mm x 185 mm
    MTBF
    > 100 years
    MTTFD
    > 100 years
    Response time
    ≥ 13 ms
    Detectable object shape
    Almost any
    Integrated application
    Field evaluationOutput of measurement data
    Number of field sets
    4 fields
    Simultaneous evaluation cases
    4
    Filter
    Echo filterFog filterParticle filterAverage filterGlare filter
    Serial
    ✔ , RS-232, RS-422
    Data transmission rate
    9.6 kBaud ... 500 kBaud
    USB
    Remark
    Mini-USB
    Function
    Service interface
    Digital inputs
    2 (digital)
    Digital outputs
    3 (digital)
    Optical indicators
    5 LEDs (Additional 7-segment display)
    Object remission
    2 % ... > 1,000 % (reflectors)
    Emitted radiation
    Industrial environment (IEC 61000-6-3:2020 / EN IEC 61000-6-3:2007+A1:2011)
    Electromagnetic immunity
    Industrial environment (IEC 61000-6-2:2016 / EN IEC 61000-6-2:2019)
    Sine test
    10 Hz ... 150 Hz, Amplitude 0.35 mm to 5 g, 20 cycles1)
    Shock resistance
    15 g, 11 ms, 6 single shocks/axis2)10 g, 16 ms, 1,000 continuous shocks/axis2)
    Impact resistance
    IK05, IK06, IK07 (DIN EN 50102:09-1997)
    Ambient operating temperature
    –30 °C ... +50 °C
    Storage temperature
    –40 °C ... +70 °C
    Ambient light immunity
    70,000 lx
    Note on use
    The sensor does not constitute a safety component as defined by relevant legislation on machine safety.
    cTUVus certificate
    ECLASS 5.0
    27270990
    ECLASS 5.1.4
    27270990
    ECLASS 6.0
    27270913
    ECLASS 6.2
    27270913
    ECLASS 7.0
    27270913
    ECLASS 8.0
    27270913
    ECLASS 8.1
    27270913
    ECLASS 9.0
    27270913
    ECLASS 10.0
    27270913
    ECLASS 11.0
    27270913
    ECLASS 12.0
    27270913
    ETIM 5.0
    EC002550
    ETIM 6.0
    EC002550
    ETIM 7.0
    EC002550
    ETIM 8.0
    EC002550
    UNSPSC 16.0901
    41111615
    Download Datasheet

    Manuals, CAD models, certificates and other materials are available on the manufacturer's website: