Level sensors | LFP Inox | LFP0320-G1NMB | Communication interface: IO-Link | Process connection: G ¾ A | Probe length: 320 mm | Probe type: Rod probe in hygienic design | Remote amplifier: No | Output signal: 1 x PNP + 1 x PNP/NPN + 4 mA ... 20 mA / 0 V ... 10 V | Connection type: Round connector M12 x 1, 5-pin | Process temperature: –20 °C ... +150 °C | Process pressure: –1 bar ... 16 bar | Housing design: With viewing window made from PMMA (acrylic glass) | Wetted parts: Stainless steel 1.4404 / 316L, PEEK | Housing material: Stainless steel 1,4305 | Enclosure rating: IP67, IP69 | Display: yes | PWIS-cleaned: no | Bluetooth: no
Medium
Fluids
Measurement
Switch, Continuous
Design
Standard amplifier
Probe type
Rod probe in hygienic design
Probe length
320 mm
Process pressure
–1 bar ... 16 bar
Process temperature
–20 °C ... +150 °C
Accuracy of sensor element
± 5 mm
Reproducibility
≤ 2 mm
Resolution
1 mm
Response time
400 ms1)
Dielectricity constant
≥ 5 for rod probe≥ 1.8 with coaxial tube
Conductivity
No limitation
Deactivated area at process connection
25 mm2)
Deactivated area at end of probe
≥ 10 mm3)
MTTF
194.3 years (EN ISO 13849-1)
Display
✔
Communication interface
IO-Link
Supply voltage
12 V DC ... 30 V DC1)
Power consumption
≤ 75 mA at 24 V DC without output load
Initialization time
≤ 2 s
Protection class
III
Connection type
Round connector M12 x 1, 5-pin
Output signal
1 x PNP + 1 x PNP/NPN + 4 mA ... 20 mA / 0 V ... 10 V
Output load
4 mA ... 20 mA < 500 Ohm at Uv > 13,5 V, 4 mA ... 20 mA < 400 Ohm at Uv > 12 V, 0 V ... 10 V > 750 Ohm at Uv 14 ≥ V
Hysteresis
≥ 2 mm2)
Output current
< 100 mA
Inductive load
< 1 H
Capacitive load
< 100 nF
Enclosure rating
IP67 (EN 60529)IP69 (EN 60529)
Temperature drift
< 0.1 mm/K
Lower signal level
3.8 mA ... 4 mA, 0 V
Upper signal level
20 mA ... 20.5 mA, 10.5 V
EMC
EN 61326-2-3, 2014/30/EU
Wetted parts
Stainless steel 1.4404 / 316LPEEK
Surface roughness
Ra ≤ 0,8 µm
Process connection
G ¾ A
Housing material
Stainless steel 1,4305
Housing design
With viewing window made from PMMA (acrylic glass)
Max. probe load
≤ 6 Nm
Ambient operating temperature
–20 °C ... +60 °C
Ambient temperature, storage
–40 °C ... +80 °C
Outdoor use
Only with weather hood
EU declaration of conformity
✔
UK declaration of conformity
✔
ACMA declaration of conformity
✔
Moroccan declaration of conformity
✔
China RoHS
✔
FDA certificate
✔
cULus certificate
✔
IO-Link certificate
✔
Food contact material manufacturer declaration
✔
Information according to Art. 3 of Data Act (Regulation EU 2023/2854)
✔
ECLASS 5.1.4
27200513
ECLASS 6.0
27200513
ECLASS 7.0
27200513
ECLASS 8.0
27200513
ECLASS 9.0
27200513
ECLASS 10.0
27200513
ECLASS 11.0
27200513
ECLASS 12.0
27200513
ECLASS 13.0
27200513
ECLASS 14.0
27200513
ECLASS 15.0
27200513
ETIM 6.0
EC001447
ETIM 7.0
EC001447
ETIM 8.0
EC001447
ETIM 9.0
EC001447
ETIM 10.0
EC001447
UNSPSC 091201.0
41113710
UNSPSC 100501.0
41113710
UNSPSC 111201.0
41113710
UNSPSC 120901.0
41113710
UNSPSC 131201.0
41113710
UNSPSC 140801.0
41113710
UNSPSC 151101.0
41113710
UNSPSC 160901.0
41113710
UNSPSC 171001.0
41113710
UNSPSC 180801.0
41113710
UNSPSC 190501.0
41113710
UNSPSC 200601.0
41113710
UNSPSC 210901.0
41113710
UNSPSC 220601.0
41113710
UNSPSC 230701.0
41113710
UNSPSC 240301.0
41113710
UNSPSC 250901.0
41113710
UNSPSC 260801.0
41113710
Lae alla teabeleht
Juhendid, CAD-mudelid, sertifikaadid ja muud materjalid on tootja veebisaidil:
Ava toote leht tootja veebisaidil