    Safety switches | i10 Lock | i10-M0453 Lock | Locking principle: Power to release | Locking force FZh: 1,000 N | Connection type Detail: Cable gland, 3 x M20 | Safe series connection: None, only individual wiring (with diagnostics) | Positive action N/C solenoid monitoring contacts: 2 | N/O solenoid monitoring contacts: 0 | Positive action N/C door monitoring contacts: 2

    Sensor principle
    Electro-mechanical
    Positive action N/C solenoid monitoring contacts
    2
    N/O solenoid monitoring contacts
    0
    Positive action N/C door monitoring contacts
    2
    N/O door monitoring contacts
    0
    N/C contact for door monitoring
    0
    Locking force Fmax
    1,300 N (EN ISO 14119)
    Locking force FZh
    1,000 N (EN ISO 14119)
    Actuation force
    ≥ 10 N
    Retaining force
    ≤ 20 N
    Actuation frequency
    ≤ 1,200 /h
    Actuation directions
    4
    Approach speed
    ≤ 20 m/min
    B10dparameter
    3 x 106switching cycles (with small load)
    Type
    Type 2 (EN ISO 14119)
    Actuator coding level
    Low coding level (EN ISO 14119)
    Safe state in the event of a fault
    The switch has no internal fault detection and is unable to assume a safe state in the event of a fault. Fault detection is performed by the connected safety-related logic unit.
    Safe series connection
    None, only individual wiring (with diagnostics)
    Connection type
    Cable gland, 3 x M20
    Conductor cross section
    0.34 mm² ... 1.5 mm²
    Contamination rating
    3
    Switching principle
    Slow action switching element
    Usage category
    AC-15/DC-13 (IEC 60947-5-1)
    Rated operating current (voltage)
    4 A (230 V AC)4 A (24 V DC)
    Rated insulation voltage Ui
    250 V
    Rated impulse withstand voltage Uimp
    2,500 V
    Type of output
    Electro-mechanical contacts
    Power consumption
    ≤ 8 W
    Short-circuit protection
    4 A gG
    Switching voltage
    ≥ 12 V DC
    Switching current (switching voltage)
    1 mA (24 V DC)
    Solenoid operating voltage
    (20.4 V DC ... 26.4 V DC)
    Switch-on time of magnet
    100 %
    Locking principle
    Power to release
    Weight
    0.46 kg
    Housing material
    Glass-fiber reinforced thermoplastic
    Mechanical life
    1 x 106switching cycles
    Enclosure rating
    IP67 (IEC 60529)
    Ambient operating temperature
    –20 °C ... +55 °C
    Storage temperature
    –20 °C ... +55 °C
    EU declaration of conformity
    UK declaration of conformity
    China RoHS
    cULus certificate
    ECLASS 5.0
    27272603
    ECLASS 5.1.4
    27272603
    ECLASS 6.0
    27272603
    ECLASS 6.2
    27272603
    ECLASS 7.0
    27272603
    ECLASS 8.0
    27272603
    ECLASS 8.1
    27272603
    ECLASS 9.0
    27272603
    ECLASS 10.0
    27272603
    ECLASS 11.0
    27272603
    ECLASS 12.0
    27272603
    ETIM 5.0
    EC002593
    ETIM 6.0
    EC002593
    ETIM 7.0
    EC002593
    ETIM 8.0
    EC002593
    UNSPSC 16.0901
    39122205
    Download Datasheet

    Manuals, CAD models, certificates and other materials are available on the manufacturer's website: