Fixed mount barcode scanners | CLV62x | CLV620-0300 | Optical focus: Fixed focus | Communication interface: PROFINET, EtherCAT®, Serial, CAN, CANopen, PROFIBUS DP | Type: Cable connection variant | Max. reading distance: 365 mm | Code resolution: 0.2 mm ... 1 mm | Code printing process: Label (printed codes) | Sensor type: Line scanner | Window material: Glass | Cold storage applications: no | Enclosure rating: IP65
Version
Mid Range
Reading field
Front
Sensor type
Line scanner
Optical focus
Fixed focus
Light source
Light spot, laser, Visible, Red, 655 nm
Laser class
2, complies with 21 CFR 1040.10 except for the conformance according to “Laser Notice No. 56” from May 8, 2019 (EN 60825-1:2014+A11:2021, IEC 60825-1:2014)
Aperture angle
≤ 50°
Reading distance
60 mm ... 365 mm1)
Scanning frequency
400 Hz ... 1,200 Hz
Code resolution
0.2 mm ... 1 mm
Connection type
1 x 15-pin D-Sub HD male connector (2 m)
Supply voltage
10 V DC ... 30 V DC
Power consumption
4.5 W
Housing material
Aluminum die cast
Housing color
Light blue (RAL 5012)
Window material
Glass
Enclosure rating
IP65 (DIN 40 050)
Protection class
III (VDE 0106/IEC 1010-1)
Poids
225 g, with connecting cable
Dimensions (L x W x H)
61 mm x 66 mm x 38 mm
MTBF
100,000 h
MTTF
40,000 h (Laser diode)1)
Readable code structures
1D codes
Bar code types
All current code types, Code 39, Code 128, Code 93, Codabar, GS1-128 / EAN 128, UPC / GTIN / EAN, Interleaved 2 of 5, Pharmacode, GS1 DataBar, Telepen, MSI/Plessey
Code printing process
Label (printed codes)
Print ratio
2:1 ... 3:1
No. of codes per scan
1 ... 20 (Standard decoder)1 ... 6 (SMART620)
No. of codes per reading interval
1 ... 50 (auto-discriminating)
No. of characters per reading interval
1,500500 (for multiplexer function in CAN operation)
No. of multiple readings
1 ... 99
PROFINET
✔
EtherCAT®
✔
Serial
✔ , RS-232, RS-422, RS-485
CAN
✔
Function
SICK CAN sensor network CSN (CAN controller/CAN device, multiplexer/server)
CANopen
✔
Data transmission rate
20 kbit/s ... 1 Mbit/s
PROFIBUS DP
✔
Type of fieldbus integration
Optional over external fieldbus module CDF600-2
Digital inputs
4 (“Sensor 1”, “Sensor 2”, 2 inputs via optional parameter storage CMC600 in CDB620/CDM420)
Digital outputs
4 (“Result 1”, “Result 2”, 2 outputs via optional parameter storage CMC600 in CDB620/CDM420)
Reading pulse
Digital inputs, non-powered, serial interface, auto pulse, CAN
Optical indicators
6 LEDs (Ready, Result, laser, Data, CAN, LNK TX)
Acoustic indicators
Beeper/buzzer (can be switched off, can be allocated as a result indication function)
Configuration software
SOPAS ET
Electromagnetic compatibility (EMC)
EN 61000-6-3 (2001-10) / EN 61000-6-2:2005
Vibration resistance
EN 60068-2-6 (1995)
Shock resistance
EN 60068-2-27 (1993)
Ambient operating temperature
0 °C ... +40 °C
Storage temperature
–20 °C ... +70 °C
Relative humidity
90 %, Non-condensing
Ambient light immunity
2,000 lx, on barcode
Bar code print contrast (PCS)
≥ 60 %
Note on use
For Ethernet connection please use an Ethernet version of CLV6xx
EU declaration of conformity
✔
UK declaration of conformity
✔
ACMA declaration of conformity
✔
China RoHS
✔
cULus certificate
✔
Ethercat certificate
✔
Profinet certificate
✔
Laser safety (IEC 60825-1) declaration of manufacturer
✔
Information according to Art. 3 of Data Act (Regulation EU 2023/2854)
✔
4Dpro
✔
ECLASS 5.0
27280102
ECLASS 5.1.4
27280102
ECLASS 6.0
27280102
ECLASS 6.2
27280102
ECLASS 7.0
27280102
ECLASS 8.0
27280102
ECLASS 8.1
27280102
ECLASS 9.0
27280102
ECLASS 10.0
27280102
ECLASS 11.0
27280102
ECLASS 12.0
27280102
ETIM 5.0
EC002550
ETIM 6.0
EC002550
ETIM 7.0
EC002550
ETIM 8.0
EC002550
UNSPSC 16.0901
43211701