Fixed mount barcode scanners | CLV49x | CLV490-3010 | Optical focus: Auto focus | Max. reading distance: 1,600 mm | Code resolution: 0.17 mm ... 0.4 mm | Enclosure rating: IP65
Version
High Density
Reading field
Oscillating mirror
Scanner design
Line scanner
Optical focus
Auto focus (alternative: dynamic focus control)
No. of distance configurations
≤ 8
Focus adjustment time
≤ 20 ms
Focus trigger source
Switching inputs “IN 0 ... IN 4” / data interface / timer
Light source
Visible red light (650 nm)
Laser class
2 (DIN EN 60825-1)
Aperture angle
≤ 50°
Reading distance
400 mm ... 1,600 mm1)
Scanning frequency
600 Hz ... 1,200 Hz
Code resolution
0.17 mm ... 0.4 mm
Oscillating mirror functions
Fixed (adjustable position), oscillating (variable or fixed amplitude), one shot
Oscillation frequency
0.5 Hz ... 4 Hz
Angle of deflection
–20° ... 20° (can be adjusted via software)
Connection type
1 x 15-pin D-sub HD plug1 x 15-pin D-Sub HD device female connector
Supply voltage
18 V DC ... 30 V DC
Power consumption
18 W
Housing material
Aluminum die cast, no materials containing silicone on outside
Housing color
Light blue (RAL 5012)
Enclosure rating
IP65 (DIN 40 050)
Protection class
III (VDE 0106)
Kaal
2,200 g
Dimensions (L x W x H)
183 mm x 127.5 mm x 97.5 mm
MTBF
80,000 h
Bar code types
All current code types, Code 39, Code 128, Code 93, Codabar, GS1-128 / EAN 128, UPC / GTIN / EAN, Interleaved 2 of 5
Print ratio
2:1 ... 3:1
No. of codes per scan
1 ... 12 (Standard decoder)1 ... 6 (SMART decoder)
No. of codes per reading interval
1 ... 50 (auto-discriminating)
No. of characters per reading interval
600
No. of multiple readings
1 ... 99
Digital inputs
6 (Sensor, IN 0 ... IN 4)
Digital outputs
4 (“Result 1” ... “Result 4”)
Reading pulse
Switching input “Sensor” (+ “IN 4”), non-powered, data interface, OTS (Omni tracking)
Optical indicators
4 LEDs (function indicator)
Electromagnetic compatibility (EMC)
EN 61000-6-2 (2001-10) / EN 61000-6-3 (2001-10) / EN 61000-6-3 / A11 (2004-07)
Vibration resistance
EN 60068-2-6 (1995)
Shock resistance
EN 60068-2-27 (1993)
Ambient operating temperature
0 °C ... +40 °C
Storage temperature
–20 °C ... +70 °C
Permissible relative humidity
± 90 %, Non-condensing
Ambient light immunity
2,000 lx, on barcode
Life cycle phase
Discontinued
ECLASS 5.0
27280102
ECLASS 5.1.4
27280102
ECLASS 6.0
27280102
ECLASS 6.2
27280102
ECLASS 7.0
27280102
ECLASS 8.0
27280102
ECLASS 8.1
27280102
ECLASS 9.0
27280102
ECLASS 10.0
27280102
ECLASS 11.0
27280102
ECLASS 12.0
27280102
ETIM 5.0
EC002550
ETIM 6.0
EC002550
ETIM 7.0
EC002550
ETIM 8.0
EC002550
UNSPSC 16.0901
43211701