BES05TL (BES M18EG2-PSC50B-BV02-X02) - Inductive sensors for hazardous areas - Dimension: Ø 18 x 57 mm, Style Housing: M18x1, Installation: for flush mounting, Range: 5 mm, Switching output: PNP normally open (NO), Switching frequency: 180 Hz, Housing material: AISI 316L, Material sensing surface: AISI 316L, Connection: Cable, 2 m, PVC, Operating voltage Ub: 10...30 VDC, Ambient temperature: -20...60 °C, see certificate, Ex category: NEC 500: Class I, Division 2, NEC 500: Class II, Division 2, NEC 500/505: Class III, NEC 505: Class I, Zone 2, NEC 505: Zone 22, IP rating: IP67, Approval/Conformity: CSA, WEEE
Style Housing
M18x1
Installation
for flush mounting
Range
5 mm
Switching output
PNP normally open (NO)
Switching frequency
180 Hz
Housing material
AISI 316L
Material sensing surface
AISI 316L
Connection
Cable, 2 m, PVC
Operating voltage Ub
10...30 VDC
Ambient temperature
-20...60 °C, see certificate
Ex category
NEC 500: Class I, Division 2NEC 500: Class II, Division 2NEC 500/505: Class IIINEC 505: Class I, Zone 2NEC 505: Zone 22
IP rating
IP67
Approval/Conformity
CSAWEEE
Manufacturer
Balluff GmbH
Manual
BES M18EG2-PSC50B-BV.-X02 'AO' | (English, French)
Tariff Code
85365019
Disposal instructions
Download
Инструкции, CAD-модели, сертификаты и другие материалы — на сайте производителя:
Открыть страницу товара на сайте производителя