SICK

SLG25S-160SER21A00

SKU: 1150322 Available to order
Price excluding VAT

Request a quote

    Automation light grids | SLG-2 | SLG25S-160SER21A00 | Optical light exit: Slim | Beam separation: 25 mm | Operating range: 1.5 m | Detection height: 1,600 mm | Length of cable: 150 mm

    Included with delivery
    1 × sender1 × receiver1 × Quick Start Guide1 x safety notes
    Functional principle
    Sender/receiver
    Limit values
    70 mm ... 2,150 mm
    Parallel beam (recommended)
    70 mm ... 1,500 mm
    3 x cross beam (recommended)
    160 mm ... 1,500 mm
    Distance from 1st Beam to leading edge of housing (connection side)
    4.6 mm
    Distance from last beam to leading edge of housing (top)
    19.6 mm1)
    Detection height
    1,600 mm
    Beam separation
    25 mm
    Optical light exit
    Slim
    Minimum detectable object (MDO), parallel beam
    30 mm2)
    Minimum detectable object (MDO), 3 x cross beam
    ≥ 16.5 mm2)
    Beam function
    Parallel beam
    Pin 2 (MF)
    Teach-in input
    Pin 4 (OUT)
    Object detection output = “HIGH”
    IO-Link (process data)
    QL/QintStatus, System status, Beam status
    Teach-in (default)
    Auto teach-in
    Light source
    LED
    Type of light
    Infrared light
    Number of beams
    64
    Normative reference
    EN 62471:2008-09 | IEC 62471:2006, modified
    LED risk group marking
    Free group
    Wave length
    850 nm
    Average service life
    Average service life: 100,000 h at TU= +25 °C
    Initialization time
    0.4 s ... 2 s3)
    Teach-in time
    0.75 s ... 50 s3)
    Scan time, parallel beam
    3.1 ms
    Scan time, cross beam
    6.2 ms
    Repeatability, parallel beam
    3.1 ms
    Repeatability, cross beam
    9.4 ms
    Minimum dwell time, parallel beam
    6.2 ms
    Minimum dwell time, cross beam
    12.5 ms
    Max. response time, parallel beam
    10.1 ms
    Max. response time, cross beam
    19.3 ms
    Type of synchronization
    Optical (2 beams)
    IO-Link
    ✔ , V1.1
    Data transmission rate
    COM3 (230,4 kBaud)
    Maximum cable length
    20 m
    Cycle time
    2.3 ms
    Process data length
    32 Byte
    Supply voltage UB
    DC 18 V DC ... 30 V DC1)
    Ripple
    ≤ 1.3 Vpp
    Sender
    ≤ 39.8 mA2)
    Receiver
    ≤ 77.4 mA2)
    Type
    Push-pull: PNP/NPN
    Output signal voltage HIGH/LOW
    UB-3 V/<3 V
    Output load, Inductive
    1 H
    Output load, capacitive
    100 nF
    Output current Imax.
    100 mA
    Output current, rest
    < 0.5 mA
    Number
    1
    Input signal voltage HIGH/LOW
    >15 V/<5 V
    Protection class
    III3)
    UL File No.
    NRKH.E181493 & NRKH7.E181493
    Circuit protection
    UVconnections, reverse polarity protectedOutput Q short-circuit protectedOutputs overcurrent and short-circuit protected
    Width
    11.8 mm
    Height
    1,599.2 mm
    Depth
    24.1 mm
    Connection type
    Cable with M12 male connector, 4-pin
    Cable diameter
    3.4 mm
    Conductor cross section
    0.14 mm²
    Length of cable
    150 mm
    Cable material
    PVC
    Housing
    Aluminum
    Front screen
    PMMA
    Weight
    2,160 g
    Overvoltage protection (required)
    1
    Enclosure rating
    IP651)IP67
    Ambient temperature, operation
    –30 °C ... +55 °C
    Ambient temperature, storage
    –30 °C ... +70 °C
    Ambient light immunity
    Indirect: 50,000 lx2)
    Shock resistance
    10 g, 16 ms, DIN EN 60068-2-27
    Vibration resistance
    10-150 Hz 0.5 mm, IEC 60068-2-6
    Air humidity
    ≤ 96 %, relative humidity (no condensation)
    Electromagnetic compatibility (EMC)
    EN 61000-6-2, EN 61000-6-4
    Smart Task name
    Base logics
    Logic function
    DirectANDOR
    Timer function
    DeactivatedSwitch-on delayOff delayON and OFF delayImpulse (one shot)
    Switching signal QL1
    Switching output
    Switching signal QL2
    Switching output, external input
    Device state
    Hardware error, temperature warning, operating hours warning
    Communication state
    Pin short-circuit error, invalid process data
    Status of the light signal
    Teach error, synchronization error, quality-of-run alarm
    Alarm output
    Yes
    EU declaration of conformity
    UK declaration of conformity
    ACMA declaration of conformity
    Moroccan declaration of conformity
    China RoHS
    cULus certificate
    IO-Link certificate
    Photobiological safety (IEC EN 62471)
    Information according to Art. 3 of Data Act (Regulation EU 2023/2854)
    Download Datasheet

    Manuals, CAD models, certificates and other materials are available on the manufacturer's website:

    Open product page on manufacturer's website