SICK

WTM12F-24161220A00ZDZZZZZZZZZ1

SKU: 1152326 Available to order
Price excluding VAT

Request a quote

    Photoelectric sensors | W12 | WTM12F-24161220A00ZDZZZZZZZZZ1 | Sensing range min. / max.: 10 mm / 600 mm, 0 mm / 500 mm, 10 mm / 800 mm, 0 mm / 700 mm | Functional principle: Photoelectric proximity sensor | Functional principle detail: Background suppression, Foreground suppression, MultiMode, distance value | Switching output: Push-pull: PNP/NPN | Switching mode: Light/dark switching | Connection type: Male connector M12, 4-pin | Light source: PinPoint Pro LED | Type of light: Visible red light | Housing material: Zinc diecast | Adjustment: Teach-in button, Potentiometer, Teach-Turn adjustment, IO-Link | Smart Sensor: Enhanced Sensing, efficient communication, diagnosis, Smart Task | Smart Task name: Base logics | Special features: MultiMode | Housing: Rectangular | Focus position: 200 mm

    Functional principle
    Photoelectric proximity sensor
    Functional principle detail
    Background suppression, Foreground suppression, MultiMode, distance value
    MultiMode
    1 Background suppression2 Foreground suppression3 Two Value Teach-in4 Two independent switching points5 Window6 ApplicationSelectM manual / measurement
    Sensing range min.
    10 mm (mode 1, 3, 4, 5)
    Sensing range max.
    600 mm (mode 1, 3, 4, 5)
    Adjustable switching threshold for background suppression
    40 mm ... 600 mm (mode 1, 3, 4, 5)
    Adjustable switching threshold for foreground suppression
    40 mm ... 500 mm (mode 2)
    Reference object
    Object with 90% remission factor (complies with standard white according to DIN 5033)
    Minimum distance between set sensing range and background (black 6% / white 90%)
    1 mm, at a distance of 200 mm (mode 1, 3, 4, 5)
    Minimum object height at set sensing range in front of black background (6% remission factor)
    1 mm, at a distance of 200 mm (mode 2)
    Recommended sensing range for the best performance
    50 mm ... 320 mm
    Resolution
    1 mm
    Accuracy
    Typ. 12 mm at a distance of 50 ... 250 mm1)4)
    Distance value output
    Via IO-Link
    Update rate of the distance value
    8 ms
    Light source
    PinPoint Pro LED
    Type of light
    Visible red light
    Shape of light spot
    Rectangular
    Light spot size (distance)
    8 mm x 7 mm (200 mm)
    Maximum dispersion of the emitted beam around the standardized transmission axis (squint angle)
    < +/- 1.0° (at TU= +23 °C)
    Focus position
    200 mm
    Normative reference
    EN 62471:2008-09 | IEC 62471:2006, modified
    LED risk group marking
    Free group
    Wave length
    635 nm
    Average service life
    100,000 h at Ta= +25 °C
    Teach-Turn adjustment
    BluePilotFor adjusting the sensing range with mode selection
    LED blue
    BluePilot: Display of mode, display of output states QL1(LED 3 permanently on) and QL2(LED 5 permanently on)
    LED green
    Operating indicatorStatic on: power onFlashing: IO-Link mode
    LED yellow
    Status of received light beamStatic on: object presentStatic off: object not present
    Special features
    MultiMode
    MTTFD
    1,208 years
    DCavg
    0 %
    TM(mission time)
    20 years
    IO-Link
    ✔ , IO-Link V1.1
    Data transmission rate
    COM2 (38,4 kBaud)
    Cycle time
    2.3 ms
    Process data length
    16 Bit
    Process data structure
    Bit 0 = switching signal
    VendorID
    26
    DeviceID HEX
    0x8003A5
    DeviceID DEC
    8389541
    Compatible master port type
    A
    SIO mode support
    Yes
    Supply voltage UB
    10 V DC ... 30 V DC1)
    Ripple
    ≤ 5 V
    Usage category
    DC-12 (According to EN 60947-5-2)DC-13 (According to EN 60947-5-2)
    Current consumption
    ≤ 40 mA, without load. At UB= 24 V
    Protection class
    III
    Number
    2 (Complementary)
    Type
    Push-pull: PNP/NPN
    Switching mode
    Light/dark switching
    Signal voltage PNP HIGH/LOW
    Approx. UB-2.5 V / 0 V
    Signal voltage NPN HIGH/LOW
    Approx. UB/ < 2.5 V
    Output current Imax.
    ≤ 100 mA
    Circuit protection outputs
    Reverse polarity protected
    Repeatability (response time)
    100 µs (mode 1, 2, 3)2)
    Function of pin 4/black (BK)
    Digital output, light switching, object present → output QL1 HIGH (Mode 1, 3, 4, 5, 6)8)
    Function of pin 4/black (BK) – detail
    The pin 4 function of the sensor can be configured
    Function of pin 2/white (WH)
    Digital output, dark switching, object present → output ǬL1 LOW (Mode 1, 3, 5, 6)8)
    Function of pin 2/white (WH) – detail
    The pin 2 function of the sensor can be configured
    Dimensions (W x H x D)
    15.6 mm x 49.5 mm x 43.1 mm
    Connection
    Male connector M12, 4-pin
    Housing
    Metal, zinc diecast
    Front screen
    Plastic, PMMA
    Male connector
    Plastic, VISTAL®
    Weight
    Approx. 77 g
    Maximum tightening torque of the fixing screws
    1.4 Nm
    Enclosure rating
    IP66 (EN 60529)IP67 (EN 60529)IP69 (EN 60529)
    Ambient operating temperature
    –40 °C ... +60 °C
    Ambient temperature, storage
    –40 °C ... +75 °C
    Typ. Ambient light immunity
    Artificial light: ≤ 50,000 lxSunlight: ≤ 50,000 lx
    Shock resistance
    50 g, 11 ms (25 positive and 25 negative shocks along X, Y, Z axes, 150 total shocks (EN60068-2-27))
    Vibration resistance
    10 Hz ... 2,000 Hz (Amplitude 0.5 mm / 10 g, 20 sweeps per axis, for X, Y, Z axes, 1 octave/min, (EN60068-2-6))
    Air humidity
    35 % ... 95 %, relative humidity (no condensation)
    Electromagnetic compatibility (EMC)
    EN 60947-5-2
    Resistance to cleaning agent
    ECOLAB
    UL File No.
    NRKH.E181493 & NRKH7.E181493
    Smart Task name
    Base logics
    Logic function
    DirectANDOR
    Timer function
    DeactivatedSwitch-on delayOff delayON and OFF delayImpulse (one shot)
    Inverter
    Yes
    Switching frequency
    SIO Logic: 1300 Hz (mode 1, 2, 3)1)SIO Logic: 450 Hz (mode 4, 5)1)SIO Logic: 30 Hz (Mode 1, 2, 3 combined with 6)1)SIO Logic: 15 Hz (Mode 4, 5 combined with 6)1)IOL: 1200 Hz (mode 1, 2, 3)2)IOL: 450 Hz (mode 4, 5)2)IOL: 30 Hz (Mode 1, 2, 3 combined with 6)2)IOL: 15 Hz (Mode 4, 5 combined with 6)2)
    Response time
    SIO Logic: 390 µs (mode 1, 2, 3)1)SIO Logic: 400  µs (mode 4, 5)1)SIO Logic: 15 ms (Mode 1, 2, 3 combined with 6)1)SIO Logic: 30 ms (Mode 4, 5 combined with 6)1)IOL: 420 µs (mode 1, 2, 3)2)IOL: 450 µs (mode 4, 5)2)IOL: 15 ms (Mode 1, 2, 3 combined with 6)2)IOL: 30 ms (Mode 4, 5 combined with 6)2)
    Repeatability
    SIO Logic: 140 µs (mode 1, 2, 3)1)SIO Logic: 1100 µs (mode 4, 5)1)SIO Logic: 5 ms (Mode 1, 2, 3 combined with 6)1)SIO Logic: 10 ms (Mode 4, 5 combined with 6)1)IOL: 170 µs (mode 1, 2, 3)2)IOL: 1100 µs (mode 4, 5)2)IOL: 5 ms (Mode 1, 2, 3 combined with 6)2)IOL: 10 ms (Mode 4, 5 combined with 6)2)
    Switching signal QL1
    Switching output
    Switching signal ǬL1
    Switching output
    Measuring range
    Very cold, cold, moderate, warm, hot
    Device status
    Yes
    Detailed device status
    Yes
    Operating hour counter
    Yes
    Operating hours counter with reset function
    Yes
    Quality of teach
    Yes
    EU declaration of conformity
    UK declaration of conformity
    ACMA declaration of conformity
    Moroccan declaration of conformity
    China RoHS
    ECOLAB certificate
    cULus certificate
    IO-Link certificate
    Photobiological safety (IEC EN 62471)
    Information according to Art. 3 of Data Act (Regulation EU 2023/2854)
    ECLASS 5.1.4
    27270903
    ECLASS 6.0
    27270903
    ECLASS 7.0
    27270903
    ECLASS 8.0
    27270903
    ECLASS 9.0
    27270903
    ECLASS 10.0
    27270903
    ECLASS 11.0
    27270903
    ECLASS 12.0
    27270903
    ECLASS 13.0
    27270903
    ECLASS 14.0
    27270903
    ECLASS 15.0
    27270903
    ETIM 6.0
    EC002719
    ETIM 7.0
    EC002719
    ETIM 8.0
    EC002719
    ETIM 9.0
    EC002719
    ETIM 10.0
    EC002719
    UNSPSC 091201.0
    32151804
    UNSPSC 100501.0
    32151804
    UNSPSC 111201.0
    32151804
    UNSPSC 120901.0
    32151804
    UNSPSC 131201.0
    32151804
    UNSPSC 140801.0
    32151804
    UNSPSC 151101.0
    32151804
    UNSPSC 160901.0
    32151804
    UNSPSC 171001.0
    32151804
    UNSPSC 180801.0
    32151804
    UNSPSC 190501.0
    32151804
    UNSPSC 200601.0
    32151804
    UNSPSC 210901.0
    32151804
    UNSPSC 220601.0
    32151804
    UNSPSC 230701.0
    32151804
    UNSPSC 240301.0
    32151804
    UNSPSC 250901.0
    32151804
    UNSPSC 260801.0
    32151804
    Download Datasheet

    Manuals, CAD models, certificates and other materials are available on the manufacturer's website:

    Open product page on manufacturer's website