    Photoelectric sensors | W16 | WLA16P-1H162100A00 | Sensing range min. / max.: 0 m / 10 m | Functional principle: Photoelectric retro-reflective sensor | Functional principle detail: Without reflector minimum distance (autocollimation/coaxial optics) | Switching output: Push-pull: PNP/NPN | Switching mode: Light/dark switching | Connection type: Cable, 4-wire, 2 m | Light source: PinPoint LED | Type of light: Visible red light | Housing material: VISTAL® | Adjustment: IO-Link | Communication interface: IO-Link V1.1 | Smart Sensor: Enhanced Sensing, efficient communication, diagnosis, Smart Task | Smart Task name: Base logics | Housing: Rectangular

    Functional principle
    Photoelectric retro-reflective sensor
    Functional principle detail
    Without reflector minimum distance (autocollimation/coaxial optics)
    Sensing range min.
    0 m
    Sensing range max.
    10 m
    Maximum distance range from reflector to sensor (operating reserve 1)
    0 m ... 10 m
    Recommended distance range from reflector to sensor (operating reserve 3,75)
    0 m ... 7 m
    Reference reflector
    Reflector PL80A
    Recommended sensing range for the best performance
    0 m ... 7 m
    Polarisation filter
    Yes
    Light source
    PinPoint LED
    Type of light
    Visible red light
    Shape of light spot
    Point-shaped
    Light spot size (distance)
    Ø 80 mm (5 m)
    Maximum dispersion of the emitted beam around the standardized transmission axis (squint angle)
    < +/- 1.0° (at TU= +23 °C)
    Normative reference
    EN 62471:2008-09 | IEC 62471:2006, modified
    LED risk group marking
    Free group
    Wave length
    635 nm
    Average service life
    100,000 h at Ta= +25 °C
    LED blue
    BluePilot: Alignment aid
    LED green
    Operating indicatorStatic on: power onFlashing: IO-Link mode
    LED yellow
    Status of received light beamStatic on: object not presentStatic off: object presentFlashing: Below the 1.5 function reserve
    Special applications
    Detecting objects wrapped in film
    MTTFD
    690 years
    DCavg
    0%
    TM(mission time)
    20 years
    IO-Link
    ✔ , V1.1
    Data transmission rate
    COM2 (38,4 kBaud)
    Cycle time
    2.3 ms
    Process data length
    16 Bit
    Process data structure
    Bit 0 = switching signal QL1
    VendorID
    26
    DeviceID HEX
    0x80016C
    DeviceID DEC
    8388972
    Compatible master port type
    A
    SIO mode support
    Yes
    Supply voltage UB
    10 V DC ... 30 V DC1)
    Ripple
    ≤ 5 Vpp
    Usage category
    DC-12 (According to EN 60947-5-2)DC-13 (According to EN 60947-5-2)
    Current consumption
    ≤ 30 mA, without load. At UB= 24 V
    Protection class
    III
    Number
    2 (Complementary)
    Type
    Push-pull: PNP/NPN
    Switching mode
    Light/dark switching
    Signal voltage PNP HIGH/LOW
    Approx. UB-2.5 V / 0 V
    Signal voltage NPN HIGH/LOW
    Approx. UB/ < 2.5 V
    Output current Imax.
    ≤ 100 mA
    Circuit protection outputs
    Reverse polarity protected
    Repeatability (response time)
    150 µs
    Function of pin 4/black (BK)
    Digital output, light switching, object present → output QL1LOW; IO-Link communication C4)
    Function of pin 4/black (BK) – detail
    The pin 4 function of the sensor can be configured
    Function of pin 2/white (WH)
    Digital output, dark switching, object present → output ǬL1HIGH4)
    Function of pin 2/white (WH) – detail
    The pin 2 function of the sensor can be configured
    Dimensions (W x H x D)
    20 mm x 55.7 mm x 42 mm
    Connection
    Cable, 4-wire, 2 m
    Deep-freeze property
    Do not bend below 0 °C
    Conductor size
    0.14 mm²
    Cable diameter
    Ø 4.8 mm
    Length of cable (L)
    2 m
    Bending radius
    For flexible use > 12 x cable diameter
    Bending cycles
    1,000,000
    Housing
    Plastic, VISTAL®
    Front screen
    Plastic, PMMA
    Cable
    Plastic, PVC
    Weight
    Approx. 100 g
    Maximum tightening torque of the fixing screws
    1.3 Nm
    Enclosure rating
    IP66 (EN 60529)IP67 (EN 60529)IP69 (EN 60529)1)
    Ambient operating temperature
    –40 °C ... +60 °C
    Ambient temperature, storage
    –40 °C ... +75 °C
    Shock resistance
    50 g, 11 ms (25 positive and 25 negative shocks per axis, for X, Y, Z axes, 150 shocks in total (EN60068-2-27))50 g, 6 ms (5,000 positive and 5,000 negative shocks per axis, for X, Y, Z axes, 30,000 shocks in total (EN60068-2-27))
    Vibration resistance
    10 Hz ... 2,000 Hz (Amplitude 0.5 mm / 10 g, 20 sweeps per axis, for X, Y, Z axes, 1 octave/min, (EN60068-2-6))
    Air humidity
    35 % ... 95 %, relative humidity (no condensation)
    Electromagnetic compatibility (EMC)
    EN 60947-5-2
    Resistance to cleaning agent
    ECOLAB
    UL File No.
    NRKH.E181493 & NRKH7.E181493
    Smart Task name
    Base logics
    Logic function
    DirectANDORWindowHysteresis
    Timer function
    DeactivatedSwitch-on delayOff delayON and OFF delayImpulse (one shot)
    Inverter
    Yes
    Switching frequency
    SIO Logic: 800 Hz1)IOL: 650 Hz2)
    Response time
    SIO Logic: 600  µs1)IOL: 750 µs2)
    Repeatability
    SIO Logic: 300 µs1)IOL: 750 µs2)
    Switching signal QL1
    Switching output
    Switching signal ǬL1
    Switching output
    Device status
    Yes
    Quality of teach
    Yes
    Quality of run
    Yes, Contamination display
    EU declaration of conformity
    UK declaration of conformity
    ACMA declaration of conformity
    Moroccan declaration of conformity
    China RoHS
    ECOLAB certificate
    cULus certificate
    IO-Link certificate
    Photobiological safety (DIN EN 62471) certificate
    Information according to Art. 3 of Data Act (Regulation EU 2023/2854)
    ECLASS 5.1.4
    27270903
    ECLASS 6.0
    27270903
    ECLASS 7.0
    27270903
    ECLASS 8.0
    27270903
    ECLASS 9.0
    27270903
    ECLASS 10.0
    27270903
    ECLASS 11.0
    27270903
    ECLASS 12.0
    27270903
    ECLASS 13.0
    27270903
    ECLASS 14.0
    27270903
    ECLASS 15.0
    27270903
    ETIM 6.0
    EC002719
    ETIM 7.0
    EC002719
    ETIM 8.0
    EC002719
    ETIM 9.0
    EC002719
    ETIM 10.0
    EC002719
    UNSPSC 091201.0
    32151804
    UNSPSC 100501.0
    32151804
    UNSPSC 111201.0
    32151804
    UNSPSC 120901.0
    32151804
    UNSPSC 131201.0
    32151804
    UNSPSC 140801.0
    32151804
    UNSPSC 151101.0
    32151804
    UNSPSC 160901.0
    32151804
    UNSPSC 171001.0
    32151804
    UNSPSC 180801.0
    32151804
    UNSPSC 190501.0
    32151804
    UNSPSC 200601.0
    32151804
    UNSPSC 210901.0
    32151804
    UNSPSC 220601.0
    32151804
    UNSPSC 230701.0
    32151804
    UNSPSC 240301.0
    32151804
    UNSPSC 250901.0
    32151804
    UNSPSC 260801.0
    32151804
    Download Datasheet

    Manuals, CAD models, certificates and other materials are available on the manufacturer's website:

    Open product page on manufacturer's website