Safety switches | TR10 Lock | TR10-SLM03P | Locking principle: Power to lock | Locking force FZh: 1,300 N | Coding: Universally coded | Connection type Detail: Cable | Length of cable: 3 m | Safe series connection: In control cabinet (with diagnostics)
Sensor principle
RFID
Number of safe outputs
2
Coding
Universally coded
Locking force Fmax
1,690 N (EN ISO 14119)
Locking force FZh
1,300 N (EN ISO 14119)
Retaining force
0 N
Actuation directions
4
Approach speed
≥ 2 mm/s
Safety integrity level
SIL 3 (IEC 61508)
Category
Category 4 (EN ISO 13849)
Performance level
PL e (EN ISO 13849)
PFHD(mean probability of a dangerous failure per hour)
9.1 x 10-10
TM(mission time)
20 years (EN ISO 13849)
Type
Type 4 (EN ISO 14119)
Actuator coding level
Low coding level (EN ISO 14119)
Safe state in the event of a fault
At least one safety-related semiconductor output (OSSD) is in the OFF state.
Switching behavior of the OSSDs
Locking monitoring
Safe series connection
In control cabinet (with diagnostics)
Connection type
Cable
Length of cable
3 m
Long connecting cable
≤ 200 m
Cable diameter
6.5 mm
Conductor cross section
0.25 mm²
Bend radius (with fixed installation)
> 7 x cable diameter
Bend radius (with moving cable)
> 14 x cable diameter
Cable material
PVC
Conductor material
Copper
Coupling nut material
Stainless steel
Display elements
LEDs
Diagnostics indicator
✔
Status display
✔
Protection class
II (IEC 61140)
Contamination rating
3
Classification according to cULus
Class 2
Usage category
DC-13 (IEC 60947-5-1)
Rated operating current (voltage)
200 mA (24 V DC)
Rated insulation voltage Ui
75 V
Rated impulse withstand voltage Uimp
1,000 V
Supply voltage VS
24 V DC (20.4 V DC ... 26.4 V DC)
Type of output
Self-monitoring semiconductor outputs (OSSDs)
Output current
≤ 200 mA
Peak current
400 mA, 100 ms1)
Power consumption
2.5 W
Response time
100 ms for the first switch, 50 ms for each subsequent switch2)
Release time
600 ms
Risk time
100 ms
Switch-on time
7 s
Locking principle
Power to lock
Weight
0.4 kg
Housing material
ABS
Locking bolt material
Stainless steel 304
Mechanical life
5 x 105switching cycles
Enclosure rating
IP66, IP67, IP69K (IEC 60529, IEC 60529, IEC 60529)
Ambient operating temperature
0 °C ... +55 °C
Storage temperature
–25 °C ... +75 °C
Vibration resistance
10 Hz ... 55 Hz (IEC 60068-2-6)
Shock resistance
30 g, 11 ms (EN 60068-2-27)
EMC
IEC 60947-5-3
EU declaration of conformity
✔
UK declaration of conformity
✔
ACMA declaration of conformity
✔
China RoHS
✔
cULus certificate
✔
Third party certificate
✔
ECLASS 5.1.4
27272603
ECLASS 6.0
27272603
ECLASS 7.0
27272603
ECLASS 8.0
27272603
ECLASS 9.0
27272603
ECLASS 10.0
27272603
ECLASS 11.0
27272603
ECLASS 12.0
27272603
ECLASS 13.0
27272603
ECLASS 14.0
27272603
ECLASS 15.0
27272603
ETIM 6.0
EC002593
ETIM 7.0
EC002593
ETIM 8.0
EC002593
ETIM 9.0
EC002593
ETIM 10.0
EC002593
UNSPSC 091201.0
39121500
UNSPSC 100501.0
39121500
UNSPSC 111201.0
39121500
UNSPSC 120901.0
39121500
UNSPSC 131201.0
39122205
UNSPSC 140801.0
39122205
UNSPSC 151101.0
39122205
UNSPSC 160901.0
39122205
UNSPSC 171001.0
39122205
UNSPSC 180801.0
39122205
UNSPSC 190501.0
39122205
UNSPSC 200601.0
39122205
UNSPSC 210901.0
39122205
UNSPSC 220601.0
39122205
UNSPSC 230701.0
39122205
UNSPSC 240301.0
39122205
UNSPSC 250901.0
39122205
UNSPSC 260801.0
39122205
Download Datasheet
Manuals, CAD models, certificates and other materials are available on the manufacturer's website:
Open product page on manufacturer's website