    Pressure sensors | PFT | PFT-SRBX25SM2SSAAMSSZ | Pressure type: Gauge pressure | Pressure unit: bar | Measuring range: 0 bar ... 0.25 bar | Accuracy: ≤ ± 0.5 %, of the span (= ± 0.25% of the span (optionally for pressure ranges = 0.25 bar). applies inclusive of nonlinearity, hysteresis, non-repeatability, zero-point and full-scale error (corresponds to error of measurement as per IEC 61298-2) Calibrated with vertical installation position) | Process connection: M20 x 1.5 (DIN 16288) | Pressure port: Standard | Process temperature: –30 °C ... +100 °C | Seal: Without seal | Communication interface: - | Output signal: 4 mA ... 20 mA, 2-wire | Connection type: M12 round connector x 1, 4-pin, IP67 | Supply voltage: 10 V DC ... 30 V DC

    Medium
    Liquid, gaseous
    Pressure type
    Gauge pressure
    Pressure unit
    bar
    Measuring range
    0 bar ... 0.25 bar
    Process temperature
    –30 °C ... +100 °C
    Maximum ohmic load RA
    4 mA ... 20 mA, 2-wire (RA≤ (L+– 10 V) / 0.02 A [Ohm]) , 0 V ... 5 V, 3-wire (RA> 5 kOhm), 0 V ... 10 V, 3-wire (RA> 10 kOhm)
    Output signal
    4 mA ... 20 mA, 2-wire
    Communication interface
    -
    Process connection
    M20 x 1.5 (DIN 16288)
    Wetted parts
    Standard memrane: Stainless steel 316Ti
    Internal transmission fluid
    Synthetic oil (Not available for version with standard membrane for pressure ranges > 25 bar)
    Pressure port
    Standard
    Housing material
    Stainless steel 1.4571
    Connection type
    M12 round connector x 1, 4-pin
    Supply voltage
    10 V DC ... 30 V DC
    Electrical safety
    Overvoltage protection: 36 V DCShort-circuit protection: QAtowards MReverse polarity protection: L+to MProtection class: III
    Dielectric strength
    500 V DC, NEC Class 02 power supply (low voltage and low current max. 100 VA even in the event of a fault)
    CE-conformity
    Pressure equipment directive: 2014/68/EUEMC directive: 2004/108/EC, EN 61326-2-3
    Weight sensor
    Approx. 200 g
    Seal
    Without seal
    Enclosure rating
    IP671)
    Protection class III
    MTTF
    403 years
    Pressure peak dampening
    Through optional integrated pressure port 0.6 mm or 0.3 mm for process connector G ¼ according to DIN 3852-E
    Non-linearity
    ≤ ± 0.2 %, of span (Best Fit Straight Line, BFSL) according to IEC 61298-2
    Accuracy
    ≤ ± 0.5 %, of the span (= ± 0.25% of the span (optionally for pressure ranges = 0.25 bar). applies inclusive of nonlinearity, hysteresis, non-repeatability, zero-point and full-scale error (corresponds to error of measurement as per IEC 61298-2) Calibrated with vertical installation position)
    Non-repeatability
    ≤ ± 0.1 % of the span
    Response time (10 % ... 90 %)
    ≤ 1 ms ≤ 10 ms at medium temperatures below < –30°C for pressure ranges up to 25 bar or with flush-mounted membrane
    Long-term drift/one-year stability
    ≤ ± 0.2 % of span (at reference conditions)
    Temperature coefficient in rated temperature range
    Mean TC of zero: ≤ 0.2 % of span / 10 K (< 0.4 % for pressure ranges ≤ 0.25 bar)Mean TC of span ≤ 0.2 % of span / 10 K
    Rated temperature range
    0 °C ... +80 °C
    Service life
    Minimum 10 Mio. load cycles
    Ambient temperature, operation
    –20 °C ... +80 °C
    Storage temperature
    –40 °C ... +100 °C, with flush-mounted membrane and cooling element –20 °C ... +100 °C
    Shock load
    1000 g according to IEC 60068-2-27 (mechanical shock)400 g according to IEC 60068-2-27 (mechanical shock) for version with integrated cooling element
    Vibration load
    20 g according to IEC 60068-2-6 (vibration under resonance)10 g according to IEC 60068-2-6 (vibration undencr resonae) for version with integrated cooling element
    EU declaration of conformity
    UK declaration of conformity
    China RoHS
    ECLASS 5.1.4
    27200614
    ECLASS 6.0
    27200614
    ECLASS 7.0
    27200614
    ECLASS 8.0
    27200614
    ECLASS 9.0
    27200614
    ECLASS 10.0
    27200614
    ECLASS 11.0
    27200614
    ECLASS 12.0
    27200614
    ECLASS 13.0
    27200614
    ECLASS 14.0
    27200614
    ECLASS 15.0
    27200614
    ETIM 7.0
    EC011478
    ETIM 8.0
    EC011478
    ETIM 9.0
    EC011478
    ETIM 10.0
    EC011478
    UNSPSC 091201.0
    41112410
    UNSPSC 100501.0
    41112410
    UNSPSC 111201.0
    41112410
    UNSPSC 120901.0
    41112410
    UNSPSC 131201.0
    41112410
    UNSPSC 140801.0
    41112410
    UNSPSC 151101.0
    41112410
    UNSPSC 160901.0
    41112410
    UNSPSC 171001.0
    41112410
    UNSPSC 180801.0
    41112410
    UNSPSC 190501.0
    41112410
    UNSPSC 200601.0
    41112410
    UNSPSC 210901.0
    41112410
    UNSPSC 220601.0
    41112410
    UNSPSC 230701.0
    41112410
    UNSPSC 240301.0
    41112410
    UNSPSC 250901.0
    41112410
    UNSPSC 260801.0
    41112410
    Télécharger la fiche technique

    Manuels, modèles CAO, certificats et autres documents — sur le site du fabricant :

    Ouvrir la page produit sur le site du fabricant