Specialty
SPEETEC closes the gap between tactile measuring wheel systems and complex laser Doppler sensors – and is suitable for almost all surfaces and objects thanks to the non-contact measurement that uses no measuring elements. This opens up new fields of application in motion monitoring.NCV50B is the preferred choice for retrofitting and use in end-customer applications where easy mounting is important. The NCV50B achieves a very high measurement accuracy with large mounting tolerances, which allows quick and easy mounting without a reference measurement or calibration.Non-contact measurement on moving objects without measuring elements.Class 1 laser
MTTFd: mean time to dangerous failure
33 years1)
Light source
2 continuous beam lasers1)
Laser class
1 (IEC 60825-1:2014)2)
Type of light
Invisible infrared light
Typ. measurement field size (distance)
2 mm x 3 mm (at 50 mm)8 mm x 3 mm (at 45 mm)8 mm x 3 mm (at 55 mm)
Laser power (per laser)
0.78 mW3)
Nominal measuring distance
50 mm
Static mounting tolerance
Ca. ± 5 mm1)
Possible static measuring distance
30 ... 100 mm2)
Direction of movement
1D, x-direction
Movement detection
Bidirectional
Measuring increment (µm/pulse)
2,000 (At 90° electrical)
Speed measuring range
> 0 m/s ... 10 m/s3)
Permissible acceleration
≤ 30 m/s²
Measurement accuracy
0.1 %4)
Internal sampling rate
330 µs
Supply voltage
12 V ... 30 V
Communication interface
HTL / Push pull
Output frequency
≤ 625 kHz
Connection type
Male connector, M12, 8-pin, A-coded1)
Parameterization and diagnostic interface with digital input and output
No
Load current
≤ 30 mA, per channel
Reverse polarity protection
✔
Protection class
III according to DIN EN 61140
Short-circuit resistant outputs
✔2)
Initialization time
Max. 3 s3)
Dimensions
140 mm x 95 mm x 32.5 mm (without plug)
Plug insert
PA66, copper-zinc alloy (CuZn)
Permissible pitch angle
≤ ± 1.5°1)
Permissible yaw angle
≤ ± 1.5°1)
Permissible roll angle
≤ ± 10°1)
EMC
EN 61000-6-2, EN 61000-6-3
Enclosure rating
IP65 (EN 60529)1)IP67 (EN 60529)1)
Permissible relative humidity
70 %2)
Operating temperature range
0 °C ... +45 °C3)
Storage temperature range
–32 °C ... +60 °C, without package
Resistance to shocks
30 g, 6 ms (EN 60068-2-27)
Resistance to vibration
20 g, 10 Hz ... 2,000 Hz (EN 60068-2-6)
EU declaration of conformity
✔
UK declaration of conformity
✔
ACMA declaration of conformity
✔
Moroccan declaration of conformity
✔
Information according to Art. 3 of Data Act (Regulation EU 2023/2854)
✔