    Measuring wheel encoders | MWS250 | MWS250-D4WHC01500 | Measuring wheel circumference: 12 ″ | Measuring wheel surface: PUR | Communication interface: 4.5 V ... 32 V, Incremental, TTL, RS-422 | Supply voltage: 4.5 V ... 32 V | Connection type: Male connector, M12, 8-pin, radial | Resolution in pulses/mm: 4.9 | Specialty: Programmable DFS60 encoder preset to 1,500 pulses and TTL incremental interface

    Specialty
    Programmable DFS60 encoder preset to 1,500 pulses and TTL incremental interface
    MTTFD(mean time to dangerous failure)
    300 years (EN ISO 13849-1)1)2)
    Pulses per revolution
    1,500
    Resolution in pulses/mm
    4.9
    Measuring increment (resolution in mm/pulse)
    0.21)2)
    Repeatability
    < 0.1 mm3)
    Communication interface
    Incremental
    Communication Interface detail
    TTL / RS-422
    Programmable/configurable
    Number of signal channels
    6-channel
    Connection type
    Male connector, M12, 8-pin, radial
    Supply voltage
    4.5 V ... 32 V
    Reverse polarity protection
    Short-circuit protection of the outputs
    ✔1)2)
    Measuring wheel circumference
    12 ″
    Measuring wheel surface
    PUR1)
    Mounting
    Dual wheel mount
    Spring element
    Hardened steel
    Measuring wheel core
    Aluminum
    Spring arm
    Aluminum
    Start up torque
    0.8 Ncm
    Operating torque
    0.6 Ncm
    Bearing lifetime
    3.6 x 10^10 revolutions
    Maximum travel/deflection of spring arm
    10 mm
    Recommended pretension
    10 N2)
    Max. permissible working area for the spring (continuous operation)
    ± 15 mm
    Recommended spring deflection
    10 mm ... 30 mm
    Service life of spring element
    > 1 million cycles3)
    Mounting position relative to the measuring object
    Possible from above or below
    Moment of inertia of the rotor
    40 gcm²
    Attached measuring wheel
    BEF-MR10012VU, 2153197
    Attached reference encoder
    DFS60A-TJPC65536, 1036960, See the reference encoder for further technical data.
    EMC
    According to EN 61000-6-2 and EN 61000-6-3
    Enclosure rating
    IP65 (IEC 60529)
    Operating temperature range
    –40 °C ... +100 °C
    Storage temperature range
    –40 °C ... +100 °C, without package
    ECLASS 5.0
    27270501
    ECLASS 5.1.4
    27270501
    ECLASS 6.0
    27270590
    ECLASS 6.2
    27270590
    ECLASS 7.0
    27270501
    ECLASS 8.0
    27270501
    ECLASS 8.1
    27270501
    ECLASS 9.0
    27270501
    ECLASS 10.0
    27270790
    ECLASS 11.0
    27270707
    ECLASS 12.0
    27270504
    ETIM 5.0
    EC001486
    ETIM 6.0
    EC001486
    ETIM 7.0
    EC001486
    ETIM 8.0
    EC001486
    UNSPSC 16.0901
    41112113
    EU declaration of conformity
    UK declaration of conformity
    ACMA declaration of conformity
    Moroccan declaration of conformity
    China RoHS
    Download Datasheet

    Manuals, CAD models, certificates and other materials are available on the manufacturer's website:

    Open product page on manufacturer's website