Position sensors | MPS-T, MPS-064TSNPDS04 | Measuring range: 64 mm | Connection type: Cable with M8 male connector, 4-pin, 0.05 m | Switching output / output function / enclosure rating: Analog, IP67 | Electrical wiring: DC 4-wire | Communication interface: -
Cylinder type
T-slot
Cylinder types with adapter
Round body cylinderProfile cylinders and tie-rod cylindersDovetail groove cylinderSMC rail CDQ2SMC rail ECDQ2SMC cylinders with C-slot
Measuring range
64 mm1)
Housing length
77 mm
Output function
Analog
Electrical wiring
DC 4-wire
Analog output (voltage)
0 V ... 10 V2)
Analog output (current)
4 mA ... 20 mA2)
Enclosure rating
IP673)
Supply voltage
15 V DC ... 30 V DC1)
Power consumption
≤ 22 mA2)
Max. load resistance
≤ 500 Ω Power Output, at 24 V
Min. load resistance
≥ 2 kΩ3)
Protection class
III
Time delay before availability
1.5 s
Required magnetic field sensitivity, typ.
3 mT
Resolution, typ.
0.03 % FSR (max. ≥ 0.05 mm)4)
Linearity error, typ.
0.3 mm5)
Repeat accuracy, typ.
0.06 % FSR (≥ 0.1 mm)6)
Sampling rate, typ.
1 ms7)
Status indicator LED
✔
Reverse polarity protection
✔
Short-circuit protection
✔
Ambient operating temperature
–20 °C ... +70 °C
Shock and vibration resistance
30 g, 11 ms / 10 ... 55 Hz, 1 mm
EMC
According to EN 60947-5-28)
Housing material
Plastic
Connection type
Cable with M8 male connector, 4-pin, 0.05 m9)
Cable material
PUR
Conductor cross-section
0.08 mm²
UL File No.
NRKH.E181493
ECLASS 5.0
27270104
ECLASS 5.1.4
27270104
ECLASS 6.0
27270104
ECLASS 6.2
27270104
ECLASS 7.0
27270104
ECLASS 8.0
27270104
ECLASS 8.1
27270104
ECLASS 9.0
27270104
ECLASS 10.0
27270104
ECLASS 11.0
27270104
ECLASS 12.0
27274301
ETIM 5.0
EC002544
ETIM 6.0
EC002544
ETIM 7.0
EC002544
ETIM 8.0
EC002544
UNSPSC 16.0901
39122230
Download Datasheet
Manuals, CAD models, certificates and other materials are available on the manufacturer's website: