Automation light grids | MLG-2 | MLG20A-0280I10501 | Device version: Pro - Extended functionality | Inputs/outputs: RS-485 + 2 x Q (IO-Link) | Option: None | Beam separation: 20 mm | Operating range: 5 m | Detection height: 280 mm | Length of cable: 0.22 m, 0.27 m, 0.19 m | Response time: 3.6 ms | Software feature (default setting - see technical data/features): 01
Device version
Pro - Extended functionality
Sensor principle
Sender/receiver
Minimum detectable object (MDO)
20 mm1)24 mm2)3)
Beam separation
20 mm
Type of synchronization
Cable
Number of beams
15
Detection height
280 mm
Interface RS-485
System status, virtual outputs, number of broken beams, height control (last beam)/LBB, height control (first beam)/FBB, oudside dimension, inside dimension
Baud rate RS-485
9.6 kbit/s
Q1
Presence detection
Q2 / IN
Teach input
Teach
Standard mode
Standard
✔
Transparent
✔
Dust- and sunlight-resistant
✔
Cross beam
✔
Beam blanking
✔
High measurement accuracy
✔
Data interface
Object detectionHole detectionObject height measurementMeasurement of the outside dimensionMeasurement of the inside dimensionMeasurement of the object positionMeasurement of the hole position
Included with delivery
1 × sender1 × receiver4/6 xQuickFix brackets(6 x QuickFix brackets for monitoring heights above 2 m)1 × Quick Start Guide
Light source
LED, Infrared light
Wave length
850 nm
Supply voltage Vs
DC 19.2 V ... 28.8 V1)
Power consumption sender
55.75 mA2)
Power consumption receiver
123 mA2)
Ripple
< 5 Vpp
Output current Imax.
100 mA
Output load, capacitive
100 nF
Output load, Inductive
1 H
Initialization time
< 1 s
Switching output
Push-pull: PNP/NPN
Connection type
Plug, M12, 5-pin, 0.22 mMale connector M12, 8-pin, 0.27 mM12 female connector, 4-pin, D-coded, 0.19 m
Housing material
Aluminum
Display
LED
Enclosure rating
IP65, IP673)
Circuit protection
UVconnections, reverse polarity protectedOutput Q short-circuit protectedInterference pulse suppression
Protection class
III
Weight
0.849 kg
Front screen
PMMA
Option
None
UL File No.
NRKH.E181493
Maximum range
7 m1)
Minimum range
≥ 0 m
Operating range
5 m
Response time
3.6 ms2)
IO-Link
✔ , IO-Link V1.1
Maximum cable length
20 m
Cycle time
2.3 ms
VendorID
26
DeviceID HEX
800068
DeviceID DEC
8388712
Process data length
32 Byte (TYPE_2_V)1)
Serial
✔ , RS-485
Data transmission rate
1.2 kbit/s …921.6 kbit/s
Inputs/outputs
RS-485 + 2 x Q (IO-Link)
Digital output
Q1, Q2
Digital input
In1
Number
1
Shock resistance
Continuous shocks 10 g, 16 ms, 1000 shocksSingle shocks 15 g, 11 ms 3 per axle
Vibration resistance
Sinusoidal oscillation 10-150 Hz 5 g
EMC
EN 60947-5-2
Ambient light immunity
Direct: 150,000 lx1)Indirect: 200,000 lx2)
Ambient operating temperature
–30 °C ... +55 °C
Ambient temperature, storage
–40 °C ... +70 °C
Smart Task name
Base logics
EU declaration of conformity
✔
UK declaration of conformity
✔
ACMA declaration of conformity
✔
Moroccan declaration of conformity
✔
cULus certificate
✔
IO-Link certificate
✔
Photobiological safety (IEC EN 62471)
✔
ECLASS 5.0
27270910
ECLASS 5.1.4
27270910
ECLASS 6.0
27270910
ECLASS 6.2
27270910
ECLASS 7.0
27270910
ECLASS 8.0
27270910
ECLASS 8.1
27270910
ECLASS 9.0
27270910
ECLASS 10.0
27270910
ECLASS 11.0
27270910
ECLASS 12.0
27270910
ETIM 5.0
EC002549
ETIM 6.0
EC002549
ETIM 7.0
EC002549
ETIM 8.0
EC002549
UNSPSC 16.0901
39121528
Download Datasheet
Manuals, CAD models, certificates and other materials are available on the manufacturer's website:
Open product page on manufacturer's website