Automation light grids | MLG-2 WebChecker | MLG05W-0777N12501 | Device version: Web guiding | Option: None | Beam separation: 5 mm | Operating range: 2.5 m | Total measuring field width: 3,145 mm | Measuring field width detail (connection side/medium range/head side): 1,045 mm / 1,055 mm / 1,045 mm | Length of cable: 0.22 m, 0.27 m | Response time: 84 ms | Software feature (default setting - see technical data/features): 01
Device version
Web guiding
Sensor principle
Sender/receiver
Minimum object length
4 mm1)
Beam separation
5 mm
Resolution
0.1 mm
Cycle time
32 µs per beam
Repeatability
6 µm2)
Accuracy
± 0.3 mm3)
Type of synchronization
Cable
Number of beams
420
Total measuring field width
3,145 mm
Measuring field width (connection side)
1,045 mm
Blind zone (medium range)
1,055 mm
Measuring field width (head side)
1,045 mm
Q1
Alarm, general
Application
Standard mode
Included with delivery
1 × sender1 × receiver1 x Fieldbus module4/6 xQuickFix brackets(6 x QuickFix brackets for monitoring heights above 2 m)1 × Quick Start Guide
Light source
LED, Infrared light
Wave length
850 nm
Supply voltage Vs
DC 19.2 V ... 28.8 V1)
Power consumption sender
76 mA2)
Power consumption receiver
204 mA2)
Fieldbus module current consumption
115 mA
Ripple
< 5 Vpp
Output current Imax.
100 mA
Output load, capacitive
100 nF
Output load, Inductive
1 H
Initialization time
< 1 s
Switching output
Push-pull: PNP/NPN
Dimensions (W x H x D)
34 mm x 3,229.4 mm x 30.6 mm
Connection type
Plug, M12, 5-pin, 0.22 mConnector M12, 12-pin, 0.27 m
Housing material
Aluminum
Display
LED
Enclosure rating
IP65, IP673)
Circuit protection
UVconnections, reverse polarity protectedOutput Q short-circuit protectedInterference pulse suppression
Protection class
III
Kaal
6.559 kg
Front screen
PMMA
Option
None
UL File No.
NRKH.E181493
Maximum range
3.5 m1)
Minimum range
≥ 0.2 m
Operating range
2.5 m
Response time
84 ms2)
PROFINET
✔
Digital output
Q1
Number
1
Shock resistance
Continuous shocks 10 g, 16 ms, 1000 shocksSingle shocks 15 g, 11 ms 3 per axle
Vibration resistance
Sinusoidal oscillation 10-150 Hz 5 g
Ambient light immunity
100,000 lx
Ambient operating temperature
–30 °C ... +55 °C
Ambient temperature, storage
–40 °C ... +70 °C
EU declaration of conformity
✔
UK declaration of conformity
✔
ACMA declaration of conformity
✔
Moroccan declaration of conformity
✔
China RoHS
✔
cULus certificate
✔
Profinet certificate
✔
Photobiological safety (IEC EN 62471)
✔
Information according to Art. 3 of Data Act (Regulation EU 2023/2854)
✔
ECLASS 5.0
27270910
ECLASS 5.1.4
27270910
ECLASS 6.0
27270910
ECLASS 6.2
27270910
ECLASS 7.0
27270910
ECLASS 8.0
27270910
ECLASS 8.1
27270910
ECLASS 9.0
27270910
ECLASS 10.0
27270910
ECLASS 11.0
27270910
ECLASS 12.0
27270910
ETIM 5.0
EC002549
ETIM 6.0
EC002549
ETIM 7.0
EC002549
ETIM 8.0
EC002549
UNSPSC 16.0901
39121528
Lae alla teabeleht
Juhendid, CAD-mudelid, sertifikaadid ja muud materjalid on tootja veebisaidil: