SICK

MAX30N-72C11CA0200

SKU: 1154946 Available to order
Price excluding VAT

Request a quote

    Linear encoders | MAX | MAX30N-72C11CA0200 | Type: Ø 30 mm 31f7 for IN cylinder mounting – cylinder bore hole 31H8 | Cable connection direction: Radial | Pipe diameter / Damping zone / End cap: 30 mm / Flat | Supply voltage: 24 V DC (8 ... 32 V DC) | Communication interface: CANopen | Connection type: Male connector, M12 type S (20x20 mm), 5-pin | Measuring range: 0 mm ... 200 mm

    Items supplied
    Accessories not included with delivery, please order separately.
    MTTFD(mean time to dangerous failure)
    69 years (EN ISO 13849-1)1)
    Pressure pipe/End cap
    Flat
    Direction of connection
    Radial
    Measured values
    Positioning, speed
    Position (F.S.)
    0 mm ... 200 mm1)
    Speed
    0 … 1,000 mm/s
    Null zone
    21.5 mm
    Damping zone
    30 mm
    Fluid temperature
    –30 °C ... +95 °C2)
    Air humidity
    90 % (Condensation not permitted)
    Switch-on time
    < 250 ms
    Switch-on current
    5,0 A/ 50 µs
    Measuring frequency (internal)
    2 ms
    Transmission rate (cycle time)
    CANopen (0 ... 65,535 ms), factory setting: 0 ms (transmission stopped)
    Setpoint tolerance
    ≤ ± 1 mm
    Hysteresis
    ± 0,1 mm
    Repeatability
    Typ. ± 0.2 mm
    Communication interface
    CANopen
    Bus protocol
    CANopen CiA DS-301
    Device profile
    CANopen CiA DS-406
    Baud rate
    250 kbit/s
    Node ID
    11
    Connection type
    Male connector, M12 type S (20x20 mm), 5-pin
    PIN assignment
    1=n.c.; 2=V DC; 3=GND; 4=CAN_H; 5=CAN_L
    Supply voltage
    24 V DC (8 ... 32 V DC)
    Residual ripple
    < 1% S-S
    Power consumption
    ≤ 0.75 W
    Current consumption
    ≤ 30 mA
    Bus termination (external)
    120 Ω
    Overvoltage protection during power-up (60 s)
    ≤ 36 V at all poles during power-up (60 s)≤ 48 V To GND during power-up (60 s)
    Reverse polarity protection
    ≤ 36 V (at all poles) (ISO 16750-2)
    Insulation resistance
    Riso≥ 10 MΩ (ISO 16750-2)
    Dielectric strength
    500 V DC, 0 V DC (60 s) to housing (RISO≥ 1 MΩ)
    Short-circuit protection
    VS– GND on housing
    Wire length
    60 mm
    Housing
    Stainless steel 1.4305 (AISI 303)
    Pressure pipe
    Stainless steel 1.4404, AISI 316L
    O-ring
    NBR 70
    Support ring
    PTFE
    M12 flange
    Nickel-plated brass with O-ring (NBR)
    Strands
    PVC
    EMC
    EU Directive 2014/30 / EU CE marking
    ESD (air and contact discharge)
    ISO 61000-4-2: 2009 / ISO 10605: 2008
    Sine
    15 g, 24 h / axis, 55 ... 2.000 Hz (IEC 60068-2-6)
    Sine over noise
    13 g (r.m.s), 36 h / axis, 10 ... 2.000 Hz (IEC 60068-2-80)
    Broadband noise (resonance peaks removed)
    15 g (r.m.s), 48 h / axis, 10 ... 2.000 Hz (IEC 60068-2-64)
    Operating pressure PN
    320 bar
    Overload pressure Pmax= PNx 1.2
    380 bar
    Test pressure Pstat= PNx 1.5
    480 bar
    Storage
    –20 °C ... +65 °C1)
    Operation (electronics)
    –40 °C ... +105 °C2)
    Maximum air humidity
    90 % (Condensation not permitted)
    M12 male connector
    IP69K
    EU declaration of conformity
    UK declaration of conformity
    ACMA declaration of conformity
    Moroccan declaration of conformity
    China RoHS
    Information according to Art. 3 of Data Act (Regulation EU 2023/2854)
    ECLASS 5.0
    27270705
    ECLASS 5.1.4
    27270705
    ECLASS 6.0
    27270705
    ECLASS 6.2
    27270705
    ECLASS 7.0
    27270705
    ECLASS 8.0
    27270705
    ECLASS 8.1
    27270705
    ECLASS 9.0
    27270705
    ECLASS 10.0
    27270705
    ECLASS 11.0
    27270705
    ECLASS 12.0
    27274304
    ETIM 5.0
    EC002544
    ETIM 6.0
    EC002544
    ETIM 7.0
    EC002544
    ETIM 8.0
    EC002544
    UNSPSC 16.0901
    41111613
    Download Datasheet