SICK

LMS511-10100 PRO

SKU: 1046135 Disponible sur commande
Prix hors TVA

Demander un devis

    LiDAR sensors | LMS5xx | LMS511-10100 PRO | Working range: 0.2 m ... 80 m | Resolution power: Standard Resolution | Enclosure rating: IP65, IP67 | Color: Gray (RAL 7032) | Integrated application: Field evaluation, output of measurement data | Connection type: 4 x M12 round connector | Scanning frequency: 25 Hz, 35 Hz, 50 Hz, 75 Hz, 100 Hz

    Application
    Outdoor, Indoor
    Variant
    PRO
    Resolution power
    Standard Resolution
    Light source
    Infrared (905 nm, ± 10 nm)
    Laser class
    1 (EN/IEC 60825-1:2014, EN 60825-1:2014+A11:2021)
    Scanning frequency
    25 Hz35 Hz50 Hz75 Hz100 Hz
    Horizontal
    0.042°, interlaced
    Scan field flatness
    Scan field flatness combined: ± 0.72°Typical conical error: 1 sigma value - 0.11° ± 0.1°Typical tilt: 1 sigma value + 0.15° ± 0.08°
    Heating
    Self-heating with additional integrated heating
    Working range
    0.2 m ... 80 m
    At 10% remission factor
    40 m
    Measurement accuracy
    ± 24 mm
    Spot size
    Divergence: 11.9 mradAt the viewing window: 13.5 mmIn 26 m: 322 nmIn 40 m: 489 mm
    Amount of evaluated echoes
    5
    Connection type
    4 x M12 round connector
    Supply voltage
    24 V DC, ± 20 %
    Power consumption
    22 W, + 55 W heating (typical)
    Housing material
    AlSi12
    Housing color
    Gray (RAL 7032)
    Window material
    Polycarbonate, scratch-resistant coating
    Enclosure rating
    IP65 (EN 60529, Section 14.2.7)IP67 (EN 60529, Section 14.2.7)
    Protection class
    III (IEC 61140:2016-11)
    Poids
    3.7 kg
    Dimensions (L x W x H)
    160 mm x 155 mm x 185 mm
    MTBF
    > 100 years
    MTTFD
    > 100 years
    Response time
    ≥ 10 ms
    Detectable object shape
    Almost any
    Systematic error
    ± 25 mm (1 m ... 10 m)± 35 mm (10 m ... 20 m)± 50 mm (20 m ... 30 m)1)
    Statistical error
    6 mm (1 m ... 10 m)8 mm (10 m ... 20 m)14 mm (20 m ... 30 m)1)
    Integrated application
    Field evaluationOutput of measurement data
    Number of field sets
    10 fields
    Simultaneous evaluation cases
    10
    Filter
    Echo filterFog filterParticle filterAverage filterGlare filter
    Ethernet
    ✔ , TCP/IP, UDP/IP
    Serial
    ✔ , RS-232, RS-422
    CAN
    Data transmission rate
    20 kBit/s, 500 kBit/s, 1 MBit/s, Synchronization
    USB
    Remark
    Mini-USB
    Function
    Service interface
    Inputs
    4 (Digital, encoder (HTL), synchronization)
    Outputs
    6 (digital)
    Optical indicators
    5 LEDs (Additional 7-segment display)
    Remission factor
    2 % ... > 1,000 % (reflectors)
    Emitted radiation
    Industrial environment (IEC 61000-6-3:2020 / EN IEC 61000-6-3:2007+A1:2011)
    Electromagnetic immunity
    Industrial environment (IEC 61000-6-2:2016 / EN IEC 61000-6-2:2019)
    Sine test
    10 Hz ... 150 Hz, Amplitude 0.35 mm to 5 g, 20 cycles1)
    Shock resistance
    15 g, 11 ms, 6 single shocks/axis2)10 g, 16 ms, 1,000 continuous shocks/axis2)
    Impact resistance
    IK05, IK06, IK07 (DIN EN 50102:09-1997)
    Ambient operating temperature
    –30 °C ... +50 °C
    Storage temperature
    –40 °C ... +70 °C
    Ambient light immunity
    70,000 lx
    Note on use
    The sensor does not constitute a safety component as defined by relevant legislation on machine safety.
    EU declaration of conformity
    UK declaration of conformity
    ACMA declaration of conformity
    China RoHS
    KC Mark certificate
    cTUVus certificate
    Information according to Art. 3 of Data Act (Regulation EU 2023/2854)
    ECLASS 5.0
    27270990
    ECLASS 5.1.4
    27270990
    ECLASS 6.0
    27270913
    ECLASS 6.2
    27270913
    ECLASS 7.0
    27270913
    ECLASS 8.0
    27270913
    ECLASS 8.1
    27270913
    ECLASS 9.0
    27270913
    ECLASS 10.0
    27270913
    ECLASS 11.0
    27270913
    ECLASS 12.0
    27270913
    ETIM 5.0
    EC002550
    ETIM 6.0
    EC002550
    ETIM 7.0
    EC002550
    ETIM 8.0
    EC002550
    UNSPSC 16.0901
    41111615
    Télécharger la fiche technique

    Manuels, modèles CAO, certificats et autres documents — sur le site du fabricant :