Flow sensors | T-Easic FTS | FTS-H101F04B | Wetted parts: Stainless steel 1.4404 (Ra ≤ 0,8 µm) | Process connection: Permanently installed clamping ring (only in conjunction with SICK T-connectors) | Output signal: 2 push-pull digital outputs (Q1 configurable for IO-Link; Q2 configurable as analog output (4 … 20 mA) / pulse output / digital input) for flow and temperature | Process temperature: –40 °C ... +150 °C | Process pressure: –1 bar ... 100 bar, 40 bar (with SICK T-connector DN15, DN25), 25 bar (with SICK T-connector DN40), 20 bar (with SICK T-connector DN50) | Probe length: 100 mm
Measurement principle
Calorimetric measurement process
Medium
Water and oil-based liquids
Pipe diameters
≥ 25 mm1)
Process temperature
–40 °C ... +150 °C3)
Process pressure
–1 bar ... 100 bar, 40 bar (with SICK T-connector DN15, DN25), 25 bar (with SICK T-connector DN40), 20 bar (with SICK T-connector DN50)4)
Communication interface
IO-Link, IO-Link V1.1, COM3 (230.4 kbit/s)
Temperature measurement
✔
Inlet zone
5 x DN
Output zone
3 x DN
Repeatability
< 1 cm/s1)
Resolution
0.01 m/s Speed; 0.1 L/min volume; 0.1% relative (via IO-Link)
Temperature drift
< 0.5 cm / (s*K)1)
Response time
< 2.5 s2)
Measurement accuracy (temperature)
± 1 °C
Resolution (Temperature)
< 0.1 °C
Response time (temperature)
< 5 s3)
Operating mode
Relative speed (%), Volume flow and total volume, Relative teach (%)
Supply voltage
9 V DC ... 30 V DC1)
Power consumption
< 2 W at 24 V DC (without load on the outputs)< 8 W At maximum load
Initialization time
≤ 5 s≤ 10 s (IO-Link)
Protection class
III
Connection type
M12 round connector x 1, 4-pin
Output signal
2 push-pull digital outputs (Q1 configurable for IO-Link; Q2 configurable as analog output (4 … 20 mA) / pulse output / digital input) for flow and temperature
Output current
< 100 mA2)
Output load
4 mA ... 20 mA, max. 350 Ohm, if Uv < 12 V, 500 Ohm if Uv> 12 V
Lower signal level
3.5 mA ... 3.8 mA
Upper signal level
20.5 mA ... 21.5 mA
Inaccuracy
QA Pin2: < 0.5% full-range (20 mA)
Inductive load
1 H
Capacitive load
100 nF (2.5 nF, IO-Link mode)
EMC
EN 61326-1, EN 61326-2-3
Digital input limit
HIGH voltage dependent on UvLOW voltage < 4.0 V
MTTF
> 200 years
Process connection
Permanently installed clamping ring (only in conjunction with SICK T-connectors)
Wetted parts
Stainless steel 1.4404 (Ra ≤ 0,8 µm)
Housing material
Stainless steel 1.4305 / 303
Enclosure rating
IP67 / IP691)
Probe diameter
8 mm
Probe length
100 mm
Minimum immersion length
12 mm
Distance to pipe wall
10 mm
Ambient operating temperature
–40 °C ... +70 °C1)
Ambient temperature, storage
–40 °C ... +80 °C
EU declaration of conformity
✔
UK declaration of conformity
✔
ACMA declaration of conformity
✔
Moroccan declaration of conformity
✔
China RoHS
✔
cULus certificate
✔
IO-Link certificate
✔
Food contact material manufacturer declaration
✔
Information according to Art. 3 of Data Act (Regulation EU 2023/2854)
✔
ECLASS 5.1.4
27273101
ECLASS 6.0
27273101
ECLASS 7.0
27273101
ECLASS 8.0
27273101
ECLASS 9.0
27273101
ECLASS 10.0
27273101
ECLASS 11.0
27273101
ECLASS 12.0
27274801
ECLASS 13.0
27274801
ECLASS 14.0
27274801
ECLASS 15.0
27274801
ETIM 6.0
EC002580
ETIM 7.0
EC002580
ETIM 8.0
EC002580
ETIM 9.0
EC002580
ETIM 10.0
EC002580
UNSPSC 091201.0
41112501
UNSPSC 100501.0
41112501
UNSPSC 111201.0
41112501
UNSPSC 120901.0
41112501
UNSPSC 131201.0
41112501
UNSPSC 140801.0
41112501
UNSPSC 151101.0
41112501
UNSPSC 160901.0
41112501
UNSPSC 171001.0
41112501
UNSPSC 180801.0
41112501
UNSPSC 190501.0
41112501
UNSPSC 200601.0
41112501
UNSPSC 210901.0
41112501
UNSPSC 220601.0
41112501
UNSPSC 230701.0
41112501
UNSPSC 240301.0
41112501
UNSPSC 250901.0
41112501
UNSPSC 260801.0
41112501
Download Datasheet
Manuals, CAD models, certificates and other materials are available on the manufacturer's website:
Open product page on manufacturer's website