Measurement principle
Calorimetric (flow, temperature), piezoresistive (pressure)
Medium
Compressed air (air quality ISO 8573-1:2010 [3:4:4]), Argon, nitrogen, carbon dioxide
Measured values
Mass, volume, Mass flow rate, Volumetric flow rate, Energy, Flow velocity, pressure, Temperature
Nominal width measuring tube
DN 50
Process temperature
–20 °C ... +60 °C
Process pressure
0 bar ... 16 bar2)
Communication interface
IO-Link, IO-Link V1.1
Display
✔128 x 128 pixels, adjustable rotary OLED display (90° steps) and 4 pushbuttons
Standard
± 6 % of the measured value + 0.6% of the measuring range limit value (extended measuring range)1)
Enhanced
± 8 % of the measured value + 1% of the measuring range limit value (extended measuring range)1)
Repeatability
± 1.5 % From measured value1)
Measurement accuracy (temperature)
± 2 °C2)
Repeatability (temperature)
± 0.5 °C2)
Measurement accuracy (pressure)
± 1.5 % of measuring range end value
Non-linearity (pressure)
± 0.5 % from measuring range
Repeatability (pressure)
± 0.2 % from measuring range
Supply voltage
17 V DC ... 30 V DC1)
Power consumption
< 4.5 W at 24 V DC without output load
Connection type
M12 x 1 round connector, 5-pin, A-coded
Output signal
1x analog output 4 mA ... 20 mA + 1x digital/analog output (PNP, NPN, push-pull, 4 mA ... 20 mA / switchable), frequency pulse output + 1x digital output (PNP, NPN, push-pull, switchable), IO-Link V1.1 (COM3 / 230K4 baud)
Output load
4 mA ... 20 mA, max. 500 ohm
Lower signal level
3.5 mA ... 3.8 mA
Upper signal level
20.5 mA ... 21.5 mA
Inaccuracy
QA Pin2: < 0.5% full-range (20 mA)Q2 Pin5: < 0.5% full-range (20 mA)
Capacitive load
≤ 100 nF (2.5 nF, IO-Link mode)
Enclosure rating
IP65 (IEC 60529)2)IP67 (IEC 60529)2)
Process connection
2” NPT male thread
Wetted parts
Probe: stainless steel 1.4305, PA6; seal: FKM (Viton®), Measurement channel: stainless steel 1.4301
Housing material
PC+ABS, PA66+PA6I GF50, PC, TPE, stainless steel 1.4301
Ambient operating temperature
–20 °C ... +60 °C1)
Ambient temperature, storage
–40 °C ... +80 °C
EU declaration of conformity
✔
UK declaration of conformity
✔
ACMA declaration of conformity
✔
Moroccan declaration of conformity
✔
Information according to Art. 3 of Data Act (Regulation EU 2023/2854)
✔