Specialty
Cable, 5-wire, 1.5 m, M12 male connector with 5-pin male connector at cable endAlso included with delivery:Mounting plate: 022-190-001-260Mounting plate: 022-190-001-270Hexagon screw, 2 pcs. M5 x 12: 022-240-301-340Hexagon screw, 2 pcs. M5 x 30: 022-240-302-390Hexagon nut, 2 pcs. M5: 022-150-100-130Washer, 4 pcs. 5.3 x 9 x 1: 022-170-001-340
Standard reference device
DKV60E-21EPA0004
MTTFD(mean time to dangerous failure)
600 years (EN ISO 13849-1)1)
Measuring increment (resolution in mm/pulse)
1
Measuring step deviation
± 18°, / pulses per revolution
Error limits
± 0.5 mm/m, subject to the measuring wheel (wheel + surface)
Initialization time
≤ 3 ms
Communication interface
Incremental
Communication Interface detail
HTL / Push pull
Number of signal channels
6-channel
Operating power consumption (no load)
50 mA
Connection type
Special version
Connection type Detail
Cable, 5-wire, 1.5 m, M12 male connector with 5-pin male connector at cable end
Supply voltage
10 V ... 30 V
Maximum output frequency
≤ 300 kHz
Reference signal, number
1
Reference signal, position
90°, electric, logically gated with A and B
Reverse polarity protection
✔
Short-circuit protection of the outputs
✔1)
Measuring wheel circumference
200 mm
Measuring wheel surface
Cross knurled aluminium1)
Spring arm design
69.5 mm spring arm
Spring element
Spring steel, anti-corrosive
Measuring wheel core
Spring steel, anti-corrosive
Start up torque
0.9 Ncm (at 20 °C)
Operating torque
0.6 Ncm (at 20 °C)
Operating speed
≤ 1,500 min⁻¹
Bearing lifetime
2 x 10^9 revolutions
Maximum travel/deflection of spring arm
8 mm at 14 N spring travel
Recommended pretension
8 N at 4 mm deflection2)
Max. permissible working area for the spring (continuous operation)
± 1.5 mm
Recommended spring deflection
2 mm ... 8 mm
EMC
According to EN 61000-6-2 and EN 61000-6-3
Permissible relative humidity
90 % (Condensation not permitted)
Operating temperature range
–20 °C ... +85 °C
Storage temperature range
–40 °C ... +70 °C, without package
Resistance to shocks
50 g, 7 ms (DIN/EN 60068-2-27)
Resistance to vibration
20 g, 10 Hz ... 2,000 Hz (EN 60068-2-6)
EU declaration of conformity
✔
UK declaration of conformity
✔
ACMA declaration of conformity
✔
Information according to Art. 3 of Data Act (Regulation EU 2023/2854)
✔