Measuring wheel encoders | DFV60 | DFV60A-22PC00S12 | Measuring wheel circumference: 500 mm | Measuring wheel surface: Cross knurled aluminium | Communication interface: 4.5 V ... 32 V, Incremental, TTL, HTL | Supply voltage: 4.5 V ... 32 V | Connection type: Male connector, M12, 8-pin, radial | Resolution in pulses/mm: 131 | Specialty: Measuring wheels pre-mounted, 500 mm (4084733)
Special device
✔
Specialty
Measuring wheels pre-mounted, 500 mm (4084733)
Standard reference device
DFV60A-22PC65536, 1051309
Items supplied
DFV60 spring arm (part number: 2056155) not included with delivery
MTTFD(mean time to dangerous failure)
300 years (EN ISO 13849-1)1)
Pulses per revolution
65,536
Resolution in pulses/mm
131 Pulses/mm1)
Measuring increment (resolution in mm/pulse)
0.0076 mm/pulse2)
Measuring step deviation
± 0.002°3)
Error limits
± 4 mm/m, subject to measuring wheel (measuring wheel surface + measuring surface + ambient conditions)
Initialization time
30 ms
Communication interface
Incremental
Communication Interface detail
TTL / HTL
Programmable/configurable
✔
Connection type
Male connector, M12, 8-pin, radial
Power consumption max. without load
≤ 30 mA
Supply voltage
4.5 V ... 32 V
Load current max.
30 mA
Maximum output frequency
820 kHz
Reference signal, number
1
Reference signal, position
90°, electric, logically gated with A and B
Reverse polarity protection
✔
Short-circuit protection of the outputs
✔
Measuring wheel circumference
500 mm
Measuring wheel surface
Cross knurled aluminium1)
Mass
+ 500 g
Shaft
Stainless steel
Flange
Aluminum
Housing
Aluminum
Cable
PUR
Spring element
Not contained in the scope of delivery of the system
Measuring wheel core
Aluminum
Start up torque
0.8 Ncm (at 20 °C)
Operating torque
0.6 Ncm (at 20 °C)
Operating speed
1,500 min⁻¹
Maximum operating speed
3,000 min⁻¹2)
Bearing lifetime
3 x 10^9 revolutions
Maximum travel/deflection of spring arm
40 mm
Max. permissible working area for the spring (continuous operation)
± 10 mm
Recommended spring deflection
20 mm ... 40 mm
Mounting position relative to the measuring object
Preferably from above, from below possible
EMC
According to EN 61000-6-2 and EN 61000-6-4
Enclosure rating
IP65
Permissible relative humidity
90 % (Condensation not permitted)
Operating temperature range
–20 °C ... +100 °C
Storage temperature range
–40 °C ... +100 °C, without package
Resistance to shocks
70 g, 6 ms (EN 60068-2-27)
Resistance to vibration
30 g, 10 Hz ... 2,000 Hz (EN 60068-2-6)
EU declaration of conformity
✔
UK declaration of conformity
✔
ACMA declaration of conformity
✔
Moroccan declaration of conformity
✔
China RoHS
✔
cULus certificate
✔
Information according to Art. 3 of Data Act (Regulation EU 2023/2854)
✔
ECLASS 5.0
27270501
ECLASS 5.1.4
27270501
ECLASS 6.0
27270590
ECLASS 6.2
27270590
ECLASS 7.0
27270501
ECLASS 8.0
27270501
ECLASS 8.1
27270501
ECLASS 9.0
27270501
ECLASS 10.0
27270790
ECLASS 11.0
27270707
ECLASS 12.0
27270504
ETIM 5.0
EC001486
ETIM 6.0
EC001486
ETIM 7.0
EC001486
ETIM 8.0
EC001486
UNSPSC 16.0901
41112113