Specialty
ATM60-A4A0-K08 successor:Flange adapter 2072298 premountedCable, 8-wire, with male connector, M23, universal, 0.1 mPreconfiguration:- Max. resolution: 12 bit x 12 bit (4.096 x 4.096)- sync_on: 1- shift_ri_on: 0- centered: 0- V/R wire: active- Gray code- Position: 8388608- SSI mode synchronAHM36 adapted to 60 mm face mount flange
Standard reference device
AHM36A-SCPJ014x12, 1097559
MTTFD(mean time to dangerous failure)
230 years (EN ISO 13849-1)1)
Number of steps per revolution (max. resolution)
4,096 (12 bit)
Number of revolutions
4,096 (12 bit)
Max. resolution (number of steps per revolution x number of revolutions)
12 bit x 12 bit (4,096 x 4,096)
Error limits G
0.35° (at 20 °C)1)
Repeatability standard deviation σr
0.2° (at 20 °C)2)
Communication interface
SSI
Initialization time
100 ms1)
Position forming time
125 µs
Parameterising data
Number of steps per revolutionNumber of revolutionsPRESETCounting directionCode typeOffset of position bitsPosition error bitRound axis functionalitySSI mode
Code sequence parameter adjustable
CW/CCW (V/R̅) configurable via programming tool or cable
Set (electronic adjustment)
H-active (L = 0 - 3 V, H = 4,0 - UsV)
CW/CCW (counting sequence when turning)
L-active (L = 0 - 1 V, H = 2,0 - Us V)
Connection type
Special version
Connection type Detail
Cable, 8-wire, with male connector, M23, universal, 0.1 m
Supply voltage
4.5 ... 32 V DC
Power consumption
≤ 1.5 W (without load)
Reverse polarity protection
✔
Mechanical design
Solid shaft, face mount flange
Characteristics of the shaft
With flat
Flange type / stator coupling
AHM36 adapted to 60 mm face mount flange with pre-assembled adapter flange BEF-FA-020-036, 2072298
Shaft material
Stainless steel
Start up torque
1 Ncm (+20 °C)
Operating torque
< 1 Ncm (+20 °C)
Permissible shaft loading
40 N (radial)20 N (axial)
Operating speed
≤ 6,000 min⁻¹
Moment of inertia of the rotor
2.5 gcm²
Bearing lifetime
3.6 x 10^8 revolutions
Angular acceleration
≤ 500,000 rad/s²
EMC
According to EN 61000-6-2 and EN 61000-6-3
Enclosure rating
IP66 (IEC 60529)IP67 (IEC 60529)
Permissible relative humidity
90 % (Condensation not permitted)
Operating temperature range
–40 °C ... +100 °C
Storage temperature range
–40 °C ... +100 °C, without package
Resistance to shocks
100 g, 6 ms (EN 60068-2-27)
Resistance to vibration
20 g, 10 Hz ... 2,000 Hz (EN 60068-2-6)
EU declaration of conformity
✔
UK declaration of conformity
✔
ACMA declaration of conformity
✔
Moroccan declaration of conformity
✔
Information according to Art. 3 of Data Act (Regulation EU 2023/2854)
✔