SICK

EXS-06D6203B020, EXE-06D6203B020

SKU: p360470 Available to order
Price excluding VAT

Request a quote

    Safety light curtains | deTec | EXS-06D6203B020, EXE-06D6203B020 | Product version: deTec4 Core Ex | System part: Pair | Application: Explosive areas | Ex-approvals: Ex II 2G / 2D, NFPA 70 / NEC 500, classes I, II, III, div. 1 | Safety level: PL e, SIL 3, Type 4 | Resolution: 30 mm | Scanning range: 10 m | Protective field height: 600 mm | Connection type: Connecting cable, 30 m, flying leads, 5-wire | Enclosure rating: IP65, IP66 | Items supplied: Sender in explosion-proof enclosure with connecting cable, 30 m, receiver in explosion-proof enclosure with connecting cable, 30 m, 4 handles including screws, test rod with diameter corresponding to the resolution of the safety light curtain, operating instructions on CD-ROM

    Product version
    deTec4 Core Ex
    Application
    Explosive areas
    Ex-approvals
    ATEX for gas: II 2 G Ex db IIB T6 GbATEX for dust: II 2 D Ex tb IIIC T56°C Db IP6XNFPA 70/NEC 500 Class I, Div. 1, Groups C and DNFPA 70/NEC 500 Class II, Div. 1, Groups E, F and GNFPA 70/NEC 500 Class III, Div. 1
    System part
    Pair
    Resolution
    30 mm
    Scanning range
    10 m
    Protective field height
    600 mm
    Response time
    10 ms
    Synchronization
    Optical synchronization
    Items supplied
    Sender in explosion-proof enclosure with connecting cable, 30 mReceiver in explosion-proof enclosure with connecting cable, 30 m4 handles including screwsTest rod with diameter corresponding to the resolution of the safety light curtainOperating instructions on CD-ROM
    Type
    Type 4 (IEC 61496-1)
    Safety integrity level
    SIL 3 (IEC 61508)
    Category
    Category 4 (ISO 13849-1)
    Performance level
    PL e (ISO 13849-1)
    PFHD(mean probability of a dangerous failure per hour)
    3.7 x 10-9
    TM(mission time)
    20 years (ISO 13849-1)
    Safe state in the event of a fault
    At least one OSSD is in the OFF state.
    Protective operation
    Automatic calibration of the protective field width
    System connection
    Connecting cable, 30 m, flying leads, 5-wire
    Length of cable
    30 m
    Cable diameter
    7.4 mm
    Conductor cross section
    0.75 mm²
    Display elements
    LEDs
    Protection class
    III (IEC 61140)
    Supply voltage VS
    24 V DC (19.2 V ... 28.8 V)
    Ripple
    ≤ 10 %
    Type of output
    2 PNP semiconductors, short-circuit protected, cross-circuit monitored1)
    ON state, switching voltage HIGH
    24 V DC (VS– 2.25 V DC ... VS)
    OFF state, switching voltage LOW
    ≤ 2 V DC
    Current-carrying capacity per OSSD
    ≤ 300 mA
    Dimensions
    See dimensional drawing
    Housing cross-section
    161.8 mm x 142.1 mm
    Housing material
    Aluminum cast/AlSi7Mg0.6
    Enclosure rating
    IP65 (IEC 60529)IP66 (IEC 60529)
    Ambient operating temperature
    –20 °C ... +55 °C
    Storage temperature
    –30 °C ... +70 °C
    Air humidity
    15 % ... 95 %, Non-condensing
    Vibration resistance
    5 … 150 Hz, 3,5 mm / 1 g (EN 60068-2-6)
    Shock resistance
    15 g / 6 ms (EN 60068-2-27)
    Class
    3M4 (IEC TR 60721-4-3)
    Wave length
    850 nm
    Type of light
    Near-infrared (NIR), invisible
    ECLASS 5.0
    27272704
    ECLASS 5.1.4
    27272704
    ECLASS 6.0
    27272704
    ECLASS 6.2
    27272704
    ECLASS 7.0
    27272704
    ECLASS 8.0
    27272704
    ECLASS 8.1
    27272704
    ECLASS 9.0
    27272704
    ECLASS 10.0
    27272704
    ECLASS 11.0
    27272704
    ECLASS 12.0
    27272704
    ETIM 5.0
    EC002549
    ETIM 6.0
    EC002549
    ETIM 7.0
    EC002549
    ETIM 8.0
    EC002549
    UNSPSC 16.0901
    46171620
    Download Datasheet

    Manuals, CAD models, certificates and other materials are available on the manufacturer's website: