Functional principle
Photoelectric proximity sensor
Functional principle detail
Background suppression
Sensing range max.
1,200 mm
Adjustable switching threshold for background suppression
90 mm ... 1,200 mm
Reference object
Object with 90% remission factor (complies with standard white according to DIN 5033)
Minimum distance between set sensing range and background (black 6% / white 90%)
6 mm, at a distance of 650 mm
Recommended sensing range for the best performance
100 mm ... 700 mm
Type of light
Visible red light
Shape of light spot
Ellipse shape
Light spot size (distance)
1.3 mm x 1.1 mm (650 mm)
Maximum dispersion of the emitted beam around the standardized transmission axis (squint angle)
< +/- 1.0° (at TU= +23 °C)
Normative reference
EN 60825-1:2014, IEC 60825-1:2014
Maximum pulse power
< 6.74 mW
Average service life
50,000 h at TU= +25 °C
Teach-Turn adjustment
BluePilotFor setting the sensing range
LED blue
BluePilot: sensing range indicator
LED green
Operating indicatorStatic on: power onFlashing: IO-Link mode
LED yellow
Status of received light beamStatic on: object presentStatic off: object not present
Special applications
Detecting small objects, Detection of objects moving at high speeds, Detecting perforated objects, Detection of poorly remitting and tilted objects
Data transmission rate
COM2 (38,4 kBaud)
Process data length
16 Bit
Process data structure
Bit 0 = switching signal QL1
Compatible master port type
A
Supply voltage UB
10 V DC ... 30 V DC1)
Usage category
DC-12 (According to EN 60947-5-2)DC-13 (According to EN 60947-5-2)
Current consumption
≤ 14 mA, without load. At UB= 24 V
Switching mode
Light/dark switching
Signal voltage PNP HIGH/LOW
Approx. UB-2.5 V / 0 V
Signal voltage NPN HIGH/LOW
Approx. UB/ < 2.5 V
Output current Imax.
≤ 100 mA
Circuit protection outputs
Reverse polarity protected
Repeatability (response time)
5 ms2)
WH 2
ǬL1/MFDigital output, dark switching, object present → output ǬL1LOW4)The pin 2 function of the sensor can be configured
BK 4
QL1/CDigital output, light switching, object present → output QL1HIGH4)The pin 4 function of the sensor can be configured
Dimensions (W x H x D)
15.6 mm x 49.5 mm x 43.1 mm
Connection
Male connector M12, 4-pin
Housing
Metal, zinc diecast
Front screen
Plastic, PMMA
Male connector
Plastic, VISTAL®
Maximum tightening torque of the fixing screws
1.4 Nm
Enclosure rating
IP66 (EN 60529)IP67 (EN 60529)IP69 (EN 60529)
Ambient operating temperature
–20 °C ... +55 °C
Ambient temperature, storage
–40 °C ... +70 °C
Warm-up time
< 15 min, Where Tuis under –10 °C
Typ. Ambient light immunity
Artificial light: ≤ 50,000 lxSunlight: ≤ 50,000 lx
Shock resistance
50 g, 11 ms (25 positive and 25 negative shocks along X, Y, Z axes, 150 total shocks (EN60068-2-27))
Vibration resistance
10 Hz ... 2,000 Hz (Amplitude 0.5 mm / 10 g, 20 sweeps per axis, for X, Y, Z axes, 1 octave/min, (EN60068-2-6))
Air humidity
35 % ... 95 %, relative humidity (no condensation)
Electromagnetic compatibility (EMC)
EN 60947-5-2
Resistance to cleaning agent
ECOLAB
UL File No.
NRKH.E181493 & NRKH7.E181493
Smart Task name
Base logics
Logic function
DirectANDOR
Timer function
DeactivatedSwitch-on delayOff delayON and OFF delayImpulse (one shot)
Switching frequency
SIO Logic: 900 Hz1)IOL: 800 Hz2)
Response time
SIO logic: 550 µs1)IOL: 600 µs2)
Repeatability
SIO Logic: 200 µs1)IOL: 250 µs2)
Switching signal QL1
Switching output
Switching signal ǬL1
Switching output
Measuring range
Very cold, cold, moderate, warm, hot
Detailed device status
Yes
Operating hour counter
Yes
Operating hours counter with reset function
Yes
EU declaration of conformity
✔
UK declaration of conformity
✔
ACMA declaration of conformity
✔
Moroccan declaration of conformity
✔
Laser safety (IEC 60825-1) declaration of manufacturer
✔
Information according to Art. 3 of Data Act (Regulation EU 2023/2854)
✔