Specialty
Integrated sHub functionality for vibration and moisture measurement
Items supplied
M3 mounting screws for stator coupling not included with delivery.
Safety integrity level
SIL 2 (IEC 61508), SILCL3 (IEC 62061)1)
Category
3 (EN ISO 13849-1:2015)
Systematic suitability
SC 3 (IEC61508)
Maximum demand rate
216 µs
Performance level
PL d (EN ISO 13849-1:2015)
Basis for safety function
Safe singleturn absolute position
Safety-related resolution
13 bits
Maximum difference between Safe Position 1 and Safe Position 2
3 increments
PFH (mean probability of a dangerous failure per hour)
33 x 10-92)
Safety-related accuracy
0.135°3)
Resolution per revolution
24 bit
Number of the absolute ascertainable revolutions
4,096
Available memory area
8,192 Byte
Measurement principle
Optical
Vibration analysis
Attributes Kurtosis, a-RMS, Peak to peak
Measuring range
0 –100% relative humidity (% RH)
Temperature
–40 °C ... +125 °C, ± 0.6 °C, typ.
Measuring step
0,1 % RH / digit; 0,01 °C / digit
Code sequence
Increasing, when turning the shaft For clockwise rotation, looking in direction “A” (see dimensional drawing)
Communication interface
HIPERFACE DSL®
Initialization time
≤ 500 ms1)
Measurement external temperature resistance
32-bit value, without prefix (1 Ω) 0 ... 209.600 Ω2)
Connection type
Male connector, 4-pin
Supply voltage
7 V ... 12 V
Warm-up time voltage ramp
Max. 180 ms1)
Current consumption
≤ 150 mA2)
Shaft version
Tapered shaft
Flange type / stator coupling
Stator coupling
Dimensions
See dimensional drawing
Moment of inertia of the rotor
5 gcm²
Operating speed
≤ 9,000 min⁻¹
Angular acceleration
≤ 250,000 rad/s²
Start up torque
≤ 0.4 Ncm, +20 °C
Permissible movement static
± 1 mm, axial1)
Permissible movement dynamic
± 0.025 mm, radial2)
Life of ball bearings
50,000 h at 6,000 min-1(at a flange temperature of 70 °C)
Operating temperature range
–40 °C ... +110 °C1)
Storage temperature range
–40 °C ... +125 °C, without package
Relative humidity/condensation
90 %, Condensation not permitted
Resistance to shocks
100 g, 6 ms (according to EN 60068-2-27)
Frequency range of resistance to vibrations
50 g, 10 Hz ... 2,000 Hz (EN 60068-2-6)
EMC
According to EN 61000-6-2: 2016, EN 61000-6-4: 2006, IEC 6100-6-7: 20142)
Enclosure rating
IP40, When cover is closed and mating connector is attached (IEC 60529-1)3)
Operating height (above sea level)
2,000 m
EU declaration of conformity
✔
UK declaration of conformity
✔
ACMA declaration of conformity
✔
Moroccan declaration of conformity
✔
EC-Type-Examination approval
✔
Information according to Art. 3 of Data Act (Regulation EU 2023/2854)
✔