SICK

TTK70S-HXJ0-K02

SKU: 1099701 Available to order
Price excluding VAT

Request a quote

    Safe motor feedback systems | TTK70-S | TTK70S-HXJ0-K02 | Communication interface: HIPERFACE® | Resolution: 1 µm | Safety system: yes | Connection type: Cable, 8-wire (4 x 2 x 0.15 mm²), 0.5 m | System part: Read head | System accuracy: ± 10 µm | Technology: Magnet-coded

    Items supplied
    Magnetic tape not included with delivery
    Safety integrity level
    SIL 2 (IEC 61508), SILCL2 (EN 62061)1)
    Category
    3 (EN ISO 13849)
    Maximum demand rate
    Continuous (analog signals)
    Performance level
    PL d (EN ISO 13849)
    PFH (mean probability of a dangerous failure per hour)
    2.02 x 10-82)
    TM(mission time)
    20 years (EN ISO 13849)
    MTTFD(mean time to dangerous failure)
    73 years (EN ISO 13849)
    Safety-related accuracy
    ± 25 mm, = ± 1/4 pin length
    Safety-related measuring step
    0.25 mm
    Measuring step
    0.244 µm For interpolation of the sine/cosine signals with, e. g., 12 bits
    Measuring range
    0 mm ... 3,920 mm
    Resolution
    1 µm
    Length of period
    1 mm
    Traversing speed
    ≤ 10 m/s, 1.3 m/s up to which the absolute position can be reliably produced
    Repeatability
    < 5 µm
    System accuracy
    ± 10 µm (+20 °C)
    Measured value backlash
    < 10 µm
    Communication interface
    HIPERFACE®1)
    Code type
    Binary
    Available memory area
    1,792 Byte (E2PROM 2048)
    Supply voltage
    7 V DC ... 12 V DC
    Recommended supply voltage
    8 V DC
    Operating current
    ≤ 65 mA (without load)1)
    Connection type
    Cable, 8-wire (4 x 2 x 0.15 mm²), 0.5 m
    Dimensions
    See dimensional drawing
    Scope of delivery
    Magnetic tape not included with delivery
    Weight
    0.08 kg
    Read head material
    Zinc diecast
    EMC
    According to EN 61000-6-2 and EN 61000-6-31)
    Enclosure rating
    IP67, with mating plug inserted (IEC 60529)
    Operating temperature range
    –30 °C ... +80 °C
    Storage temperature range
    –40 °C ... +85 °C, without package
    Permissible relative humidity
    100 %, condensation permitted
    Operating height (above sea level)
    2,000 m
    Resistance to shocks
    30 g, 6 ms (EN 60068-2-27)
    Resistance to vibration
    20 g, 10 Hz ... 2,000 Hz (EN 60068-2-6)
    Maximum permitted ambient field strength
    < 3 kA/m ... 4 kA/m (3.8 mT ... 5 mT), to guarantee compliance with the quoted accuracy values2)
    Maximum permitted field strength
    < 150 kA/m (< 190 mT), to ensure that the magnetic tape is not permanently damaged
    EU declaration of conformity
    UK declaration of conformity
    ACMA declaration of conformity
    China RoHS
    EC-Type-Examination approval
    Information according to Art. 3 of Data Act (Regulation EU 2023/2854)
    ECLASS 5.1.4
    27270502
    ECLASS 6.0
    27270590
    ECLASS 7.0
    27270501
    ECLASS 8.0
    27270501
    ECLASS 9.0
    27270501
    ECLASS 10.0
    27273805
    ECLASS 11.0
    27273901
    ECLASS 12.0
    27273901
    ECLASS 13.0
    27273901
    ECLASS 14.0
    27273901
    ECLASS 15.0
    27273901
    ETIM 6.0
    EC001486
    ETIM 7.0
    EC001486
    ETIM 8.0
    EC001486
    ETIM 9.0
    EC001486
    ETIM 10.0
    EC001486
    UNSPSC 091201.0
    39121527
    UNSPSC 100501.0
    39121527
    UNSPSC 111201.0
    39121527
    UNSPSC 120901.0
    39121527
    UNSPSC 131201.0
    39121527
    UNSPSC 140801.0
    39121527
    UNSPSC 151101.0
    39121527
    UNSPSC 160901.0
    39121527
    UNSPSC 171001.0
    39121527
    UNSPSC 180801.0
    39121527
    UNSPSC 190501.0
    39121527
    UNSPSC 200601.0
    39121527
    UNSPSC 210901.0
    39121527
    UNSPSC 220601.0
    39121527
    UNSPSC 230701.0
    39121527
    UNSPSC 240301.0
    39121527
    UNSPSC 250901.0
    39121527
    UNSPSC 260801.0
    39121527
    Download Datasheet

    Manuals, CAD models, certificates and other materials are available on the manufacturer's website:

    Open product page on manufacturer's website