SICK

TMM88A-PKC090

SKU: 1073799 Available to order
Price excluding VAT

Request a quote

    Inertial sensors | TMS/TMM88 | TMM88A-PKC090 | Number of axis: 2 | Measuring range: ± 90° | Resolution: 0.01° | Communication interface: Analog / Current | Current output: 4 mA ... 20 mA | Programmable/configurable: yes | Programming interface: Over PGT-12-Pro | Housing material: Plastic (PBT) | Connection type: Male connector, M12, 5-pin

    MTTFD(mean time to dangerous failure)
    301 years (EN ISO 13849-1)1)
    Number of axis
    2
    Measuring range
    ± 90°
    Resolution
    0.01°
    Static measurement accuracy
    ≤ ± 60°, typ. ± 0.02°, max. ± 0.06°≤ ± 70°, typ. ± 0.04°, max. ± 0.12°≤ ± 80°, typ. ± 0.08°, max. ± 0.24°≤ ± 85°, typ. ± 0.16°, max. ± 0.48°
    Compensated cross-sensitivity (2-dimensional)
    Typ. ± 0.09°, max. ± 0.45°
    Temperature coefficient (zero point)
    Typ. +0.0088°/K, –0.0102°/K1)
    Limit frequency
    0.1 Hz ... 25 Hz, 8. range (with digital filter)
    Sampling rate
    100 Hz
    Communication interface
    Analog / Current
    Current output
    4 mA ... 20 mA
    Load resistance
    ≤ 850 Ω1)
    Parameterising data
    Measuring rangeZerosetLimit frequencyPreset valueInverting of counting directionAxis assignmentFree adjustable outbound
    Programmable/configurable
    Over PGT-12-Pro
    Initialization time
    330 ms
    Connection type
    Male connector, M12, 5-pin
    Supply voltage
    17 V DC ... 35 V DC
    Current consumption
    40 mA @ 24 V + Iloop
    Reverse polarity protection
    Short-circuit protection of the outputs
    Dimensions
    66 mm x 90 mm x 36 mm
    Weight
    200 g
    Housing material
    Plastic (PBT)
    EMC
    EN 61326-1, EN ISO 14982, EN ISO 13309
    Enclosure rating
    IP65 (IEC 60529)IP67 (IEC 60529)
    Operating temperature range
    –40 °C ... +80 °C
    Storage temperature range
    –40 °C ... +85 °C
    Resistance to shocks
    100 g, 6 ms (EN 60068-2-27)
    Resistance to vibration
    10 g, 10 Hz ... 2,000 Hz (EN 60068-2-6)
    EU declaration of conformity
    UK declaration of conformity
    ACMA declaration of conformity
    China RoHS
    Information according to Art. 3 of Data Act (Regulation EU 2023/2854)
    ECLASS 5.1.4
    27270790
    ECLASS 6.0
    27270790
    ECLASS 7.0
    27270790
    ECLASS 8.0
    27270790
    ECLASS 9.0
    27270790
    ECLASS 10.0
    27271101
    ECLASS 11.0
    27271101
    ECLASS 12.0
    27271101
    ECLASS 13.0
    27271101
    ECLASS 14.0
    27271101
    ECLASS 15.0
    27271101
    ETIM 6.0
    EC001852
    ETIM 7.0
    EC001852
    ETIM 8.0
    EC001852
    ETIM 9.0
    EC001852
    ETIM 10.0
    EC001852
    UNSPSC 091201.0
    41111613
    UNSPSC 100501.0
    41111613
    UNSPSC 111201.0
    41111613
    UNSPSC 120901.0
    41111613
    UNSPSC 131201.0
    41111613
    UNSPSC 140801.0
    41111613
    UNSPSC 151101.0
    41111613
    UNSPSC 160901.0
    41111613
    UNSPSC 171001.0
    41111613
    UNSPSC 180801.0
    41111613
    UNSPSC 190501.0
    41111613
    UNSPSC 200601.0
    41111613
    UNSPSC 210901.0
    41111613
    UNSPSC 220601.0
    41111613
    UNSPSC 230701.0
    41111613
    UNSPSC 240301.0
    41111613
    UNSPSC 250901.0
    41111613
    UNSPSC 260801.0
    41111613
    Download Datasheet

    Manuals, CAD models, certificates and other materials are available on the manufacturer's website: